The rate of false-positive results with EUS-guided fine-needle aspiration

被引:63
|
作者
Schwartz, DA
Unni, KK
Levy, MJ
Clain, JE
Wiersema, MJ
机构
[1] Mayo Clin, Div Gastroenterol & Hepatol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Pathol, Rochester, MN 55905 USA
关键词
D O I
10.1067/mge.2002.129610
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The aims of this study were to determine the rate of false-positive diagnosis with EUS-guided fine-needle aspiration and to identify factors contributing to this type of error. Methods: The records of 577 patients undergoing EUS-guided fine-needle aspiration were reviewed and a subset of 188 patients with malignant cytology who underwent surgery was identified. Operative histopathology was compared with EUS-guided fine-needle aspiration cytopathology and false-positive cases were identified. An experienced cytopathologist, who was not involved with the original interpretation of the specimens, reviewed these cases to identify any factor(s) contributing to the errors. Results: Three cases of false-positive diagnosis were identified (1.6%; 95% Cl [0.3%9 4.6%]). By aspiration site, the false-positive rates were as follows: pancreas 2/39 (5.1%),95% Cl [0.6%,17.3%]; lymph nodes 1/136 (0.7%), 95% CI [0.02%, 4.0%]; and other sites 0/13, 95% Cl [0.0%, 24.7%]. In both instances of a false-positive diagnosis for a pancreatic aspiration cytologic specimen, interpretative errors were identified. The false-positive interpretation of cytologic material aspirated from a lymph node occurred in a patient without any evidence for malignancy at surgery. In 111 patients with confirmed esophageal, gastric, or rectal malignancy undergoing EUS-guided fine-needle aspiration of nonperitumoral lymph nodes, there was no false-positive diagnosis, suggesting that specimen contamination by luminal tumor is rare. Conclusion: The overall rate of false-positive diagnosis for EUS-guided fine-needle aspiration is similar to that reported for other modalities. Most false-positive diagnoses are caused by interpretation errors.
引用
收藏
页码:868 / 872
页数:5
相关论文
共 50 条
  • [31] Impact of endoscopic ultrasonography (EUS) and EUS-guided fine-needle aspiration on the management of pancreatic cystic lesions
    Rodriguez-D'Jesus, Antonio
    Fernandez-Esparrach, Gloria
    Boadas, Jaume
    Busquets, Juli
    Fernandez-Cruz, Laureano
    Ferrer, Joana
    Vaquero, Eva C.
    Molero, Xavier
    Navarro, Salvador
    Sanchez-Cabus, Santiago
    Araujo, Isis K.
    Sendino, Oriol
    Cordova, Henry
    Sanchez-Montes, Cristina
    Gines, Angels
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2016, 28 (09) : 1094 - 1099
  • [32] EUS and EUS-guided fine-needle aspiration for the diagnosis of rectal linitis plastica secondary to prostate carcinoma
    Bhutani, MS
    GASTROINTESTINAL ENDOSCOPY, 1999, 50 (01) : 117 - 119
  • [33] Delayed gastric bleeding after EUS-guided fine-needle aspiration of autoimmune pancreatitis
    Shi, Wen
    Zhang, Shengyu
    Xu, Hui
    Feng, Yunlu
    Yang, Aiming
    ENDOSCOPIC ULTRASOUND, 2021, 10 (01) : 73 - 74
  • [34] EUS-guided fine-needle aspiration of a renal mass: an alternative method for diagnosis of malignancy
    Farrell, JJ
    Brugge, WR
    GASTROINTESTINAL ENDOSCOPY, 2002, 56 (03) : 450 - 452
  • [35] Comparison between fine-needle biopsy and fine-needle aspiration for EUS-guided sampling of subepithelial lesions: a meta-analysis
    Facciorusso, Antonio
    Sunny, Sumsum P.
    Del Prete, Valentina
    Antonino, Matteo
    Muscatiello, Nicola
    GASTROINTESTINAL ENDOSCOPY, 2020, 91 (01) : 14 - +
  • [36] EUS-guided fine needle aspiration of idiopathic abdominal masses
    Catalano, MF
    Sial, S
    Chak, A
    Sivak, MV
    Erickson, R
    Scheiman, J
    Gress, F
    GASTROINTESTINAL ENDOSCOPY, 2002, 55 (07) : 854 - 858
  • [37] Endoscopic ultrasonography (EUS) and EUS-guided Fine-needle Aspiration with Cyst Fluid Analysis in Pancreatic Cystic Neoplasms
    Repak, Rudolf
    Rejchrt, Stanislav
    Bartova, Jolana
    Malirova, Eva
    Tycova, Vera
    Bures, Jan
    HEPATO-GASTROENTEROLOGY, 2009, 56 (91-92) : 629 - 635
  • [38] Impact of EUS-guided fine-needle aspiration on lymph node staging in patients with esophageal carcinoma
    Vazquez-Sequeiros, E
    Norton, ID
    Clain, JE
    Wang, KK
    Affi, A
    Allen, M
    Deschamps, C
    Miller, D
    Salomao, D
    Wiersema, MJ
    GASTROINTESTINAL ENDOSCOPY, 2001, 53 (07) : 751 - 757
  • [39] Schwannoma of the mediastinum diagnosed by EUS-guided fine needle aspiration
    McGrath, KM
    Ballo, MS
    Jowell, PS
    GASTROINTESTINAL ENDOSCOPY, 2001, 53 (03) : 362 - 365
  • [40] Does cytotechnician training influence the accuracy of EUS-guided fine-needle aspiration of pancreatic masses?
    Petrone, Maria Chiara
    Arcidiacono, Paolo Giorgio
    Carrara, Silvia
    Mezzi, Gianni
    Doglioni, Claudio
    Testoni, Pier Alberto
    DIGESTIVE AND LIVER DISEASE, 2012, 44 (04) : 311 - 314