The rate of false-positive results with EUS-guided fine-needle aspiration

被引:63
|
作者
Schwartz, DA
Unni, KK
Levy, MJ
Clain, JE
Wiersema, MJ
机构
[1] Mayo Clin, Div Gastroenterol & Hepatol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Pathol, Rochester, MN 55905 USA
关键词
D O I
10.1067/mge.2002.129610
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: The aims of this study were to determine the rate of false-positive diagnosis with EUS-guided fine-needle aspiration and to identify factors contributing to this type of error. Methods: The records of 577 patients undergoing EUS-guided fine-needle aspiration were reviewed and a subset of 188 patients with malignant cytology who underwent surgery was identified. Operative histopathology was compared with EUS-guided fine-needle aspiration cytopathology and false-positive cases were identified. An experienced cytopathologist, who was not involved with the original interpretation of the specimens, reviewed these cases to identify any factor(s) contributing to the errors. Results: Three cases of false-positive diagnosis were identified (1.6%; 95% Cl [0.3%9 4.6%]). By aspiration site, the false-positive rates were as follows: pancreas 2/39 (5.1%),95% Cl [0.6%,17.3%]; lymph nodes 1/136 (0.7%), 95% CI [0.02%, 4.0%]; and other sites 0/13, 95% Cl [0.0%, 24.7%]. In both instances of a false-positive diagnosis for a pancreatic aspiration cytologic specimen, interpretative errors were identified. The false-positive interpretation of cytologic material aspirated from a lymph node occurred in a patient without any evidence for malignancy at surgery. In 111 patients with confirmed esophageal, gastric, or rectal malignancy undergoing EUS-guided fine-needle aspiration of nonperitumoral lymph nodes, there was no false-positive diagnosis, suggesting that specimen contamination by luminal tumor is rare. Conclusion: The overall rate of false-positive diagnosis for EUS-guided fine-needle aspiration is similar to that reported for other modalities. Most false-positive diagnoses are caused by interpretation errors.
引用
收藏
页码:868 / 872
页数:5
相关论文
共 50 条
  • [1] The rate of false-positive results with EUS-guided fine needle aspiration (FNA)
    Schwartz, DA
    Unni, K
    Levy, MJ
    Clain, JE
    Parker, MK
    Wiersema, MJ
    GASTROINTESTINAL ENDOSCOPY, 2002, 55 (05) : AB237 - AB237
  • [2] EUS-guided fine-needle aspiration in the mediastinum
    Barawi, M
    Gress, M
    GASTROINTESTINAL ENDOSCOPY, 2000, 52 (06) : S12 - S17
  • [3] Effectiveness of EUS-Guided Fine-Needle Biopsy versus EUS-Guided Fine-Needle Aspiration: A Retrospective Analysis
    Kuraoka, Naosuke
    Hashimoto, Satoru
    Matsui, Shigeru
    Terai, Shuji
    DIAGNOSTICS, 2021, 11 (06)
  • [4] Maximizing the yield of EUS-guided fine-needle aspiration
    Chang, KJ
    GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : S28 - S34
  • [5] Assessment of complications of EUS-guided fine-needle aspiration
    O'Toole, D
    Palazzo, L
    Arotçarena, R
    Dancour, A
    Aubert, A
    Hammel, P
    Amaris, J
    Ruszniewski, P
    GASTROINTESTINAL ENDOSCOPY, 2001, 53 (04) : 470 - 474
  • [6] Clinical Impact of EUS-Guided Fine-Needle Aspiration
    Chennat, Jennifer
    Waxman, Irving
    NEW CHALLENGES IN GASTROINTESTINAL ENDOSCOPY, 2008, : 517 - 525
  • [7] Diagnostic value of SpyGlass for pancreatic cystic lesions: comparison of EUS-guided fine-needle aspiration and EUS-guided fine-needle aspiration combined with SpyGlass
    Du, Chen
    Chai, Ningli
    Linghu, Enqiang
    Li, Huikai
    Feng, Xiuxue
    Wang, Xiangdong
    Tang, Ping
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (02): : 904 - 910
  • [8] Diagnostic value of SpyGlass for pancreatic cystic lesions: comparison of EUS-guided fine-needle aspiration and EUS-guided fine-needle aspiration combined with SpyGlass
    Chen Du
    Ningli Chai
    Enqiang Linghu
    Huikai Li
    Xiuxue Feng
    Xiangdong Wang
    Ping Tang
    Surgical Endoscopy, 2022, 36 : 904 - 910
  • [9] Bile peritonitis after EUS-guided fine-needle aspiration
    Chen, HY
    Lee, CH
    Hsieh, CH
    GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : 594 - 596
  • [10] Comparison of EUS-guided 19-gauge Trucut needle biopsy with EUS-guided fine-needle aspiration
    Varadarajulu, S
    Fraig, M
    Schmulewitz, N
    Roberts, S
    Wildi, S
    Hawes, RH
    Hoffman, BJ
    Wallace, MB
    ENDOSCOPY, 2004, 36 (05) : 397 - 401