Use of standard for quantitation of neutrophil adherence receptors by flow cytometry

被引:0
|
作者
Latger-Cannard, V [1 ]
Regnault, V
Dumas, D
Virion, JM
Schooneman, JF
Stoltz, JF
Lecompte, T
机构
[1] CHU Nancy, Hematol Lab, F-54500 Vandoeuvre Les Nancy, France
[2] Fac Med, Lab Angiohematohemorheol, UMR CNRS 7563, Nancy, France
[3] CHU Nancy, Hop Marin, Serv Epidemiol & Evaluat Clin, Nancy, France
[4] EFS, Nancy, France
关键词
polymorphonuclear neutrophil; adherence receptors; flow cytometry; immunolabeling standard;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Adherence receptors are essential for heterotypic (endothelial cell, platelet) polymorphonuclear neutrophil (PMN) interaction. Determination of their expression level give information about activation state and functionality of PMN. Use of flow cytometry associated with an immunolabeling standard, represented by beads coated by a determined amount of immunoglobulins (Qifikit(R), Dako), allows analysis of specific antibody binding capacity and gives information about antigen density. Using this methodology, the exploration of surface adherence receptors, L-selectin (CD62L) and beta(2)-integrins (CD11a-c/CD18) from PMN unstimulated and incubated with pro-inflammatory stimuli, formyl-methionyl-leucyl-phenylalanine (fMLP) and tumor necrosis factor alpha (TNF alpha), allows, on the one hand, the establishment of basal expression values on resting PNN and on the other hand, the study of PNN reactivity. This method of quantification can be applied to clinical studies as adherence receptor deficiency syndromes or inflammatory, infectious and vascular diseases.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [41] The use of flow cytometry for fungal nuclear DNA quantification
    Talhinhas, Pedro
    Carvalho, Rita
    Loureiro, Joao
    CYTOMETRY PART A, 2021, 99 (04) : 343 - 347
  • [42] Potential use of flow cytometry in toxicity studies with microalgae
    Franqueira, D
    Orosa, M
    Torres, E
    Herrero, C
    Cid, A
    SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 247 (2-3) : 119 - 126
  • [43] Flow cytometry application for studies on adenosine A2A receptors expression
    Wojcik, Tomasz
    Bereta, Michal
    Faron-Gorecka, Agata
    Dziedzicka-Wasylewska, Marta
    Kiec-Kononowicz, Katarzyna
    ACTA POLONIAE PHARMACEUTICA, 2008, 65 (01): : 65 - 70
  • [44] Identification and Quantitation of Leukocyte Populations in Human Kidney Tissue by Multi-parameter Flow Cytometry
    Kildey, Katrina
    Law, Becker M. P.
    Muczynski, Kimberly A.
    Wilkinson, Ray
    Healy, Helen
    Kassianos, Andrew J.
    BIO-PROTOCOL, 2018, 8 (16):
  • [45] Actin assembly induced by polylysine beads or purified phagosomes: Quantitation by a new flow cytometry assay
    Defacque, H
    Egeberg, M
    Antzberger, A
    Ansorge, W
    Way, M
    Griffiths, G
    CYTOMETRY, 2000, 41 (01): : 46 - 54
  • [46] QUANTITATION OF ONCOGENE PRODUCTS BY COMPUTER-ASSISTED IMAGE-ANALYSIS AND FLOW-CYTOMETRY
    CZERNIAK, B
    HERZ, F
    WERSTO, RP
    ALSTER, P
    PUSZKIN, E
    SCHWARZ, E
    KOSS, LG
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1990, 38 (04) : 463 - 466
  • [47] The sensitive detection and quantitation of antibody to HCV by using a microsphere-based immunoassay and flow cytometry
    McHugh, TM
    Viele, MK
    Chase, ES
    Recktenwald, DJ
    CYTOMETRY, 1997, 29 (02): : 106 - 112
  • [48] The evolution of flow cytometry standard, FCS3.0, into a DICOM compatible format
    Leif, RC
    Leif, SB
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS AND ADVANCED TECHNIQUES IN ANALYTICAL CYTOLOGY, PROCEEDINGS OF, 1997, 2982 : 354 - 366
  • [49] Proposed new data file standard for flow cytometry, version FCS 3.0
    Seamer, LC
    Bagwell, CB
    Barden, L
    Redelman, D
    Salzman, GC
    Wood, JCS
    Murphy, RF
    CYTOMETRY, 1997, 28 (02): : 118 - 122
  • [50] Flow cytometry and microscopic acridine orange test: relationship with standard semen analysis
    Apedaile, AE
    Garrett, C
    Liu, DY
    Clarke, GN
    Johnston, SA
    Baker, HWG
    REPRODUCTIVE BIOMEDICINE ONLINE, 2004, 8 (04) : 398 - 407