Use of standard for quantitation of neutrophil adherence receptors by flow cytometry

被引:0
|
作者
Latger-Cannard, V [1 ]
Regnault, V
Dumas, D
Virion, JM
Schooneman, JF
Stoltz, JF
Lecompte, T
机构
[1] CHU Nancy, Hematol Lab, F-54500 Vandoeuvre Les Nancy, France
[2] Fac Med, Lab Angiohematohemorheol, UMR CNRS 7563, Nancy, France
[3] CHU Nancy, Hop Marin, Serv Epidemiol & Evaluat Clin, Nancy, France
[4] EFS, Nancy, France
关键词
polymorphonuclear neutrophil; adherence receptors; flow cytometry; immunolabeling standard;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Adherence receptors are essential for heterotypic (endothelial cell, platelet) polymorphonuclear neutrophil (PMN) interaction. Determination of their expression level give information about activation state and functionality of PMN. Use of flow cytometry associated with an immunolabeling standard, represented by beads coated by a determined amount of immunoglobulins (Qifikit(R), Dako), allows analysis of specific antibody binding capacity and gives information about antigen density. Using this methodology, the exploration of surface adherence receptors, L-selectin (CD62L) and beta(2)-integrins (CD11a-c/CD18) from PMN unstimulated and incubated with pro-inflammatory stimuli, formyl-methionyl-leucyl-phenylalanine (fMLP) and tumor necrosis factor alpha (TNF alpha), allows, on the one hand, the establishment of basal expression values on resting PNN and on the other hand, the study of PNN reactivity. This method of quantification can be applied to clinical studies as adherence receptor deficiency syndromes or inflammatory, infectious and vascular diseases.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [1] FLOW-CYTOMETRY ANALYSIS OF THE EXPRESSION OF NEUTROPHIL FMLP RECEPTORS
    ALLEN, CA
    BROOM, MF
    CHADWICK, VS
    JOURNAL OF IMMUNOLOGICAL METHODS, 1992, 149 (02) : 159 - 164
  • [2] Quantitation of baculovirus particles by flow cytometry
    Shen, CF
    Meghrous, J
    Kamen, A
    JOURNAL OF VIROLOGICAL METHODS, 2002, 105 (02) : 321 - 330
  • [3] Quantitation of AgNORs by flow versus image cytometry
    Jacquet, B
    Canet, V
    Giroud, F
    Montmasson, MP
    Brugal, G
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 2001, 49 (04) : 433 - 437
  • [4] Quantitation of microsporidia in cultured cells by flow cytometry
    Franzen, C
    Müller, A
    Hartmann, P
    Salzberger, B
    CYTOMETRY PART A, 2004, 60A (01): : 107 - 114
  • [5] A standardized procedure for quantitation of CD11b on polymorphonuclear neutrophil by flow cytometry: potential application in infectious diseases
    Latger-Cannard, V
    Besson, I
    Doco-Lecompte, T
    Lecompte, T
    CLINICAL AND LABORATORY HAEMATOLOGY, 2004, 26 (03): : 177 - 186
  • [6] Performance of calibration standards for antigen quantitation with flow cytometry
    Lenkei, R
    Gratama, JW
    Rothe, G
    Schmitz, G
    D'hautcourt, JL
    Årekrans, A
    Mandy, F
    Marti, G
    CYTOMETRY, 1998, 33 (02): : 188 - 196
  • [7] What links cod liver oil, spinach, and flow cytometry?: Flow cytometric detection and quantitation of folic acid receptors in tumor cells
    Krishan, Awtar
    CYTOMETRY PART A, 2007, 71A (11) : 897 - 898
  • [8] Assessment of neutrophil activation in whole blood by flow cytometry
    Alvarez-Larrán, A
    Toll, T
    Rives, S
    Estella, J
    CLINICAL AND LABORATORY HAEMATOLOGY, 2005, 27 (01): : 41 - 46
  • [9] A PROSPECTIVE COMPARISON OF DNA QUANTITATION BY IMAGE AND FLOW-CYTOMETRY
    BAUER, TW
    TUBBS, RR
    EDINGER, MG
    SUIT, PF
    GEPHARDT, GN
    LEVIN, HS
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1990, 93 (03) : 322 - 326
  • [10] Accurate quantitation of Leishmania infection in cultured cells by flow cytometry
    Guinet, F
    Louise, A
    Jouin, H
    Antoine, JC
    Roth, CW
    CYTOMETRY, 2000, 39 (03): : 235 - 240