To enhance contact resonance atomic force microscopy (CR-AFM) and harmonic AFM imaging simultaneously, we design a multifunctional cantilever. Precise tailoring of the cantilever's dynamic properties is realized by either mass-removing or mass-adding. As prototypes, focused ion beam drilling or depositing is used to fabricate the optimized structures. CR-AFM subsurface imaging on circular cavities covered by a piece of highly oriented pyrolytic graphite validates the improved CR frequency to contact stiffness sensitivity. The detectable subsurface depth and cavity radius increase accordingly by using the multifunctional cantilever. At the same time, the free resonance frequency of the second mode is tuned to an integer multiple of the fundamental one. Harmonic AFM imaging on polystyrene and low-density polystyrene mixture shows the improved harmonic amplitude contrast and signal strength on the two material phases. The multifunctional cantilever can be extended to enhance other similar AFM operation modes and it has potential applications in relevant fields such as mechanical characterization and subsurface imaging.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Enhancement of contact resonance atomic force microscopy subsurface imaging by mass-attached cantilevers
    Wang, Wenting
    Zhang, Wenhao
    Chen, Yuhang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2020, 53 (21)
  • [2] Double-hole cantilevers for harmonic atomic force microscopy
    Zhang, Weijie
    Chen, Yuhang
    Chu, Jiaru
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (10):
  • [3] A Systematic Method for Developing Harmonic Cantilevers for Atomic Force Microscopy
    Zhu, Benliang
    Zimmermann, Soren
    Zhang, Xianmin
    Fatikow, Sergej
    JOURNAL OF MECHANICAL DESIGN, 2017, 139 (01)
  • [4] Vibration analysis of atomic force microscope cantilevers in contact resonance force microscopy using Timoshenko beam model
    Xilong Zhou
    Pengfei Wen
    Faxin Li
    Acta Mechanica Solida Sinica, 2017, 30 (05) : 520 - 530
  • [5] Vibration analysis of atomic force microscope cantilevers in contact resonance force microscopy using Timoshenko beam model
    Xilong Zhou
    Pengfei Wen
    Faxin Li
    Acta Mechanica Solida Sinica, 2017, 30 : 520 - 530
  • [6] Vibration analysis of atomic force microscope cantilevers in contact resonance force microscopy using Timoshenko beam model
    Zhou, Xilong
    Wen, Pengfei
    Li, Faxin
    ACTA MECHANICA SOLIDA SINICA, 2017, 30 (05) : 520 - 530
  • [7] Simultaneous Scanning Ion Conductance Microscopy and Atomic Force Microscopy with Microchanneled Cantilevers
    Ossola, Dario
    Dorwling-Carter, Livie
    Dermutz, Harald
    Behr, Pascal
    Voeroes, Janos
    Zambelli, Tomaso
    PHYSICAL REVIEW LETTERS, 2015, 115 (23)
  • [8] Intermittent contact resonance atomic force microscopy
    Stan, Gheorghe
    Gates, Richard S.
    NANOTECHNOLOGY, 2014, 25 (24)
  • [9] Simultaneous Atomic Imaging of Atomic Force Microscopy and Scanning Tunneling Microscopy Using Metal Coated Cantilevers
    Sawada, Daisuke
    Hirai, Akira
    Sugimoto, Yoshiaki
    Abe, Masayuki
    Morita, Seizo
    MATERIALS TRANSACTIONS, 2009, 50 (05) : 940 - 942
  • [10] Contact atomic force microscopy using piezoresistive cantilevers in load force modulation mode
    Biczysko, P.
    Dzierka, A.
    Jozwiak, G.
    Rudek, M.
    Gotszalk, T.
    Janus, P.
    Grabiec, P.
    Rangelow, I. W.
    ULTRAMICROSCOPY, 2018, 184 : 199 - 208