Perfusion-weighted techniques in MRI grading of pediatric cerebral tumors: efficiency of dynamic susceptibility contrast and arterial spin labeling

被引:15
作者
Testud, B. [1 ]
Brun, G. [1 ]
Varoquaux, A. [2 ]
Hak, J. F. [1 ]
Appay, R. [3 ,4 ]
Le Troter, A. [5 ,6 ]
Girard, N. [1 ,5 ]
Stellmann, J. P. [5 ,6 ]
机构
[1] APHM La Timone, Dept Diagnost & Intervent Neuroradiol, 264 St Pierre St, F-13385 Marseille 05, France
[2] Aix Marseille Univ, Dept Med Imaging, APHM La Concept, Marseille, France
[3] APHM La Timone, Dept Pathol & Neuropathol, Marseille, France
[4] Aix Marseille Univ, CNRS, Inst Neurophysiopathol, INP, Marseille, France
[5] Aix Marseille Univ, CNRS, CRMBM, UMR 7339, Marseille, France
[6] APHM La Timone, CEMEREM, Marseille, France
关键词
Perfusion-weighted imaging; DSC; ASL; Pediatric brain tumor; Grading;
D O I
10.1007/s00234-021-02640-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) perfusion MRI are applied in pediatric brain tumor grading, but their value for clinical daily practice remains unclear. We explored the ability of ASL and DSC to distinguish low- and high-grade lesions, in an unselected cohort of pediatric cerebral tumors. Methods We retrospectively compared standard perfusion outcomes including blood volume, blood flow, and time parameters from DSC and ASL at 1.5T or 3T MRI scanners of 46 treatment-naive patients by drawing ROI via consensus by two neuroradiologists on the solid portions of every tumor. The discriminant abilities of perfusion parameters were evaluated by receiver operating characteristic (ROC) over the entire cohort and depending on the tumor location and the magnetic field. Results ASL and DSC parameters showed overall low to moderate performances to distinguish low- and high-grade tumors (area under the curve: between 0.548 and 0.697). Discriminant abilities were better for tumors located supratentorially (AUC between 0.777 and 0.810) than infratentorially, where none of the metrics reached significance. We observed a better differentiation between low- and high-grade cancers at 3T than at 1.5-T. For infratentorial tumors, time parameters from DSC performed better than the commonly used metrics (AUC >= 0.8). Conclusion DSC and ASL show moderate abilities to distinguish low- and high-grade brain tumors in an unselected cohort. Absolute value of K2, TMAX, tMIP, and normalized value of TMAX of the DSC appear as an alternative to conventional parameters for infratentorial tumors. Three Tesla evaluation should be favored over 1.5-Tesla.
引用
收藏
页码:1353 / 1366
页数:14
相关论文
共 41 条
[1]   Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia [J].
Alsop, David C. ;
Detre, John A. ;
Golay, Xavier ;
Guenther, Matthias ;
Hendrikse, Jeroen ;
Hernandez-Garcia, Luis ;
Lu, Hanzhang ;
MacIntosh, Bradley J. ;
Parkes, Laura M. ;
Smits, Marion ;
van Osch, Matthias J. P. ;
Wang, Danny J. J. ;
Wong, Eric C. ;
Zaharchuk, Greg .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) :102-116
[2]  
Ball W S Jr, 2001, Magn Reson Imaging Clin N Am, V9, P207
[3]   Clinical epidemiology for childhood primary central nervous system tumors [J].
Bauchet, Luc ;
Rigau, Valerie ;
Mathieu-Daude, Helene ;
Fabbro-Peray, Pascale ;
Palenzuela, Gilles ;
Figarella-Branger, Dominique ;
Moritz, Jorge ;
Puget, Stephanie ;
Bauchet, Fabienne ;
Pallusseau, Lorelei ;
Duffau, Hugues ;
Coubes, Philippe ;
Tretarre, Brigitte ;
Labrousse, Francois ;
Dhellemmes, Patrick .
JOURNAL OF NEURO-ONCOLOGY, 2009, 92 (01) :87-98
[4]   Conventional and Advanced MRI Features of Pediatric Intracranial Tumors: Supratentorial Tumors [J].
Borja, Maria J. ;
Plaza, Michael J. ;
Altman, Nolan ;
Saigal, Gaurav .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (05) :W483-W503
[5]  
Boxerman JL, 2006, AM J NEURORADIOL, V27, P859
[6]   Cerebral blood flow changes after radiation therapy identifies pseudoprogression in diffuse intrinsic pontine gliomas [J].
Calmon, Raphael ;
Puget, Stephanie ;
Varlet, Pascale ;
Dangouloff-Ros, Volodia ;
Blauwblomme, Thomas ;
Beccaria, Kevin ;
Grevent, David ;
Sainte-Rose, Christian ;
Castel, David ;
Debily, Marie-Anne ;
Dufour, Christelle ;
Bolle, Stephanie ;
Dhermain, Frederic ;
Saitovitch, Ana ;
Zilbovicius, Monica ;
Brunelle, Francis ;
Grill, Jacques ;
Boddaert, Nathalie .
NEURO-ONCOLOGY, 2018, 20 (07) :994-1002
[7]   Dynamic susceptibility-weighted contrast-enhanced perfusion MR imaging in pediatric patients [J].
Cha, S .
NEUROIMAGING CLINICS OF NORTH AMERICA, 2006, 16 (01) :137-+
[8]   Perfusion magnetic resonance imaging in pediatric brain tumors [J].
Dallery, F. ;
Bouzerar, R. ;
Michel, D. ;
Attencourt, C. ;
Promelle, V. ;
Peltier, J. ;
Constans, J. M. ;
Baledent, O. ;
Gondry-Jouet, C. .
NEURORADIOLOGY, 2017, 59 (11) :1143-1153
[9]   Arterial Spin Labeling to Predict Brain Tumor Grading in Children: Correlations between Histopathologic Vascular Density and Perfusion MR Imaging [J].
Dangouloff-Ros, Volodia ;
Deroulers, Christophe ;
Foissac, Frantz ;
Badoual, Mathilde ;
Shotar, Eimad ;
Grevent, David ;
Calmon, Raphael ;
Pages, Melanie ;
Grill, Jacques ;
Dufour, Christelle ;
Blauwblomme, Thomas ;
Puget, Stephanie ;
Zerah, Michel ;
Sainte-Rose, Christian ;
Brunelle, Francis ;
Varlet, Pascale ;
Boddaert, Nathalie .
RADIOLOGY, 2016, 281 (02) :553-566
[10]   Arterial Spin-Labeling in Children with Brain Tumor: A Meta-Analysis [J].
Delgado, A. F. ;
De Luca, F. ;
Hanagandi, P. ;
van Westen, D. ;
Delgado, A. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (08) :1536-1542