Bone Response and Soft Tissue Changes Around Implants With/Without Abutments Supporting Fixed Partial Dentures: Results From a 3-Year, Prospective, Randomized, Controlled Study

被引:18
作者
Gothberg, Catharina [1 ,2 ]
Andre, Ulrika [1 ]
Grondahl, Kerstin [3 ]
Thomsen, Peter [2 ]
Slotte, Christer [2 ,4 ]
机构
[1] Inst Postgrad Dent Educ, Dept Prosthet Dent, POB 1030, SE-55111 Jonkoping, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, VINN Excellence Ctr Biomat & Cell Therapy, Dept Biomat,Inst Clin Sci, Gothenburg, Sweden
[3] Inst Postgrad Dent Educ, Dept Oral & Maxillofacial Radiol, Jonkoping, Sweden
[4] Inst Postgrad Dent Educ, Dept Periodontol, Jonkoping, Sweden
基金
瑞典研究理事会;
关键词
abutment design; health behavior; immediate dental implant loading; marginal bone loss; soft tissue changes; suprastructure connection; DIFFERENT SURFACE-TOPOGRAPHY; IMMEDIATELY LOADED IMPLANTS; SINGLE-TOOTH IMPLANTS; LOADING PROTOCOLS; HISTOMETRIC ANALYSIS; PERIIMPLANT MUCOSA; TITANIUM IMPLANTS; DENTAL PROSTHESES; PERI-IMPLANTITIS; BIOLOGIC WIDTH;
D O I
10.1111/cid.12315
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundDiverging opinions exist regarding rough surface abutment usage, and abutment exclusion effects are unstudied. PurposeThe study aims to: (1) assess tissue response to oxidized or machined abutments or no abutment; and (2) evaluate immediate implant-loading effects. Materials and MethodsIn a 2005-2008 parallel-group randomized, clinical trial, 50 partially edentulous subjects received three Branemark TiUnite (Nobel Biocare (R), Gothenburg, Sweden) implants. Superstructures were attached via abutments (one with a TiUnite surface - AOX, and one with a machine-milled surface - AM) or directly at implant level (IL). Implants were immediately loaded (test) or unloaded for 3 months (control). Postoperative examinations were done up to 3 years. ResultsForty-seven subjects were reexamined after 3 years. Four and two implants were lost in test and control groups, respectively, during the first year. Thereafter, no implant loss occurred (95.7% survival). After 1 year, mean (SEM) peri-implant marginal bone loss (MBL) was 1.33 (0.08) mm (test) and 1.25 (0.08) mm (control). Between 1 and 3 years, a nonsignificant MBL occurred: 0.36 (0.08) mm (test) and 0.33 (0.06) mm (control). Similar MBL was found at IL (1.81 [0.93] mm) and AOX (1.77 [0.14] mm) after 3 years and was significantly lower at AM (1.42 [0.17] mm) than at IL (groups merged); 42% of the implants displayed mucosal bleeding at 3 years and probing pocket depths varied between 2.13 (0.12) mm and 3.62 (0.15) mm, significantly lower buccally. Bleeding on probing (BoP) in minute amounts was found in 30-45% of the sites and abundant BoP at about 20% of the sites. Soft tissue retracted mostly during year 1 and was more pronounced buccally. Regression analyses revealed significant effects from smoking, periodontal disease, abundant BoP, and a low initial implant stability quotient on MBL. ConclusionsNo further significant MBL was found between 1 and 3 years, irrespective of loading protocol. Use of machined abutments may benefit marginal bone stability over time.
引用
收藏
页码:309 / 322
页数:14
相关论文
共 64 条
[1]   The peri-implant hard and soft tissues at different implant systems - A comparative study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Wennstrom, J ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :212-219
[2]   The mucosal attachment to titanium implants with different surface characteristics: an experimental study in dogs [J].
Abrahamsson, I ;
Zitzmann, NU ;
Berglundh, T ;
Linder, E ;
Wennerberg, A ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2002, 29 (05) :448-455
[3]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[5]  
[Anonymous], 2010, OPEN MED-WARSAW, DOI DOI 10.1186/1741-7015-8-18
[6]   Loosening torque of prosthetic screws in metal-ceramic or metal-acrylic resin implant-supported dentures with different misfit levels [J].
Bacchi, Atais ;
Paludo, Litiane ;
Mesquita, Marcelo Ferraz ;
Schuh, Christian ;
Federizzi, Leonardo ;
Spazzin, Aloisio Oro .
JOURNAL OF BIOMECHANICS, 2013, 46 (07) :1358-1362
[7]  
Bakaeen L, 2009, INT J PERIODONT REST, V29, P297
[8]  
Barewal RM, 2012, INT J ORAL MAX IMPL, V27, P945
[9]  
Belser UC, 2004, INT J ORAL MAX IMPL, V19, P30
[10]  
Belser UC, 2009, J PERIODONTOL, V80, P140, DOI [10.1902/jop.2009.080435, 10.1902/jop.2009.080435 ]