Knee Joint: Comprehensive Assessment with 3D Isotropic Resolution Fast Spin-Echo MR Imaging-Diagnostic Performance Compared with That of Conventional MR Imaging at 3.0 T

被引:208
作者
Kijowski, Richard [1 ]
Davis, Kirkland W. [1 ]
Woods, Michael A. [1 ]
Lindstrom, Mary J. [2 ]
De Smet, Arthur A. [1 ]
Gold, Garry E. [3 ,4 ,5 ]
Busse, Reed F. [6 ]
机构
[1] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Biostat, Madison, WI 53792 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Orthoped Surg, Stanford, CA 94305 USA
[6] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
关键词
GRADING ARTICULAR-CARTILAGE; MENISCAL TEARS; MULTIPLANAR RECONSTRUCTION; ARTHROSCOPIC CORRELATION; LIGAMENT; SEQUENCES; LESIONS; EXPERIENCE; ACCURACY; ANTERIOR;
D O I
10.1148/radiol.2523090028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether a three-dimensional isotropic resolution fast spin-echo sequence (FSE-Cube) has similar diagnostic performance as a routine magnetic resonance (MR) imaging protocol for evaluating the cartilage, ligaments, menisci, and osseous structures of the knee joint in symptomatic patients at 3.0 T. Materials and Methods: This prospective, HIPAA-compliant, institutional review board approved study was performed with a waiver of informed consent. FSE-Cube was added to the routine 3.0-T MR imaging protocol performed in 100 symptomatic patients (54 male patients with a median age of 32 years and 46 female patients with a median age of 33 years) who subsequently underwent arthroscopic knee surgery. All MR imaging studies were independently reviewed twice by two musculoskeletal radiologists. During the first review, the routine MR imaging protocol was used to detect cartilage lesions, ligament tears, meniscal tears, and bone marrow edema lesions. During the second review, FSE-Cube with multiplanar reformations was used to detect these joint abnormalities. With arthroscopic results as the reference standard, the sensitivity and specificity of FSE-Cube and the routine MR imaging protocol in the detection of cartilage lesions, anterior cruciate ligament tears, and meniscal tears were calculated. Permutation tests were used to compare sensitivity and specificity values. Results: FSE-Cube had significantly higher sensitivity (P = .039) but significantly lower specificity (P = .003) than the routine MR imaging protocol for detecting cartilage lesions. There were no significant differences (P = .183-.999) in sensitivity and specificity between FSE-Cube and the routine MR imaging protocol in the detection of anterior cruciate ligament tears, medial meniscal tears, or lateral meniscal tears. FSE-Cube depicted 96.2% of medial collateral ligament tears, 100% of lateral collateral ligament tears, and 85.3% of bone marrow edema lesions identified on images obtained with the routine MR imaging protocol. Conclusion: FSE-Cube has similar diagnostic performance as a routine MR imaging protocol for detecting cartilage lesions, cruciate ligament tears, collateral ligament tears, meniscal tears, and bone marrow edema lesions within the knee joint at 3.0 T. (C) RSNA, 2009
引用
收藏
页码:486 / 495
页数:10
相关论文
共 46 条
[41]   Implementation of 3 T Lactate-Edited 3D 1H MR Spectroscopic Imaging with Flyback Echo-Planar Readout for Gliomas Patients [J].
Park, Ilwoo ;
Chen, Albert P. ;
Zierhut, Matthew L. ;
Ozturk-Isik, Esin ;
Vigneron, Daniel B. ;
Nelson, Sarah J. .
ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (01) :193-204
[42]   Evaluation of Selective Bundle Injury to the Anterior Cruciate Ligament: T2-Weighted Fast Spin-Echo 3-T MRI With Reformatted 3D Oblique Isotropic (VISTA) Versus 2D Technique [J].
Lee, Jung Eun ;
Park, Hee Jin ;
Lee, So Yeon ;
Ahn, Jin Hwan ;
Park, Jai Hyung ;
Park, Ji Yeon .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 209 (05) :W308-W316
[43]   Non-contrast-enhanced MR-angiography (MRA) of lower extremity peripheral arterial disease at 3 tesla: Examination time and diagnostic performance of 2D quiescent-interval single-shot MRA vs. 3D fast spin-Echo MRA [J].
Knobloch, Gesine ;
Lauff, Marie-Teres ;
Hanke, Moritz ;
Schwenke, Carsten ;
Hamm, Bernd ;
Wagner, Moritz .
MAGNETIC RESONANCE IMAGING, 2021, 76 :17-25
[44]   Improvement of the Diagnostic Performance of Facial Neuritis Using Contrast-Enhanced 3D T1 Black-Blood Imaging: Comparison with Contrast-Enhanced 3D T1-Spoiled Gradient-Echo Imaging [J].
Lee, Seun-Ah ;
Jo, Sang-Won ;
Chang, Suk-Ki ;
Kwon, Ki-Han .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
[45]   Improved Blood Suppression in Three-Dimensional (3D) Fast Spin-Echo (FSE) Vessel Wall Imaging Using a Combination of Double Inversion-Recovery (DIR) and Diffusion Sensitizing Gradient (DSG) Preparations [J].
Makhijani, Mahender K. ;
Hu, Houchun H. ;
Pohost, Gerry M. ;
Nayak, Krishna S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (02) :398-405
[46]   Comparison Between Isotropic 3-Dimensional Fat-Suppressed T2-Weighted Fast Spin Echo (FSE) and Conventional 2-Dimensional Fat-Suppressed Proton-Weighted FSE Shoulder Magnetic Resonance Imaging at 3-T in Patients With Shoulder Pain [J].
Horiuchi, Saya ;
Nozaki, Taiki ;
Tasaki, Atsushi ;
Ohde, Sachiko ;
Deshpande, Gautam A. ;
Starkey, Jay ;
Hara, Takeshi ;
Kitamura, Nobuto ;
Yoshioka, Hiroshi .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (04) :559-565