Knee Joint: Comprehensive Assessment with 3D Isotropic Resolution Fast Spin-Echo MR Imaging-Diagnostic Performance Compared with That of Conventional MR Imaging at 3.0 T

被引:208
作者
Kijowski, Richard [1 ]
Davis, Kirkland W. [1 ]
Woods, Michael A. [1 ]
Lindstrom, Mary J. [2 ]
De Smet, Arthur A. [1 ]
Gold, Garry E. [3 ,4 ,5 ]
Busse, Reed F. [6 ]
机构
[1] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Biostat, Madison, WI 53792 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Orthoped Surg, Stanford, CA 94305 USA
[6] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
关键词
GRADING ARTICULAR-CARTILAGE; MENISCAL TEARS; MULTIPLANAR RECONSTRUCTION; ARTHROSCOPIC CORRELATION; LIGAMENT; SEQUENCES; LESIONS; EXPERIENCE; ACCURACY; ANTERIOR;
D O I
10.1148/radiol.2523090028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether a three-dimensional isotropic resolution fast spin-echo sequence (FSE-Cube) has similar diagnostic performance as a routine magnetic resonance (MR) imaging protocol for evaluating the cartilage, ligaments, menisci, and osseous structures of the knee joint in symptomatic patients at 3.0 T. Materials and Methods: This prospective, HIPAA-compliant, institutional review board approved study was performed with a waiver of informed consent. FSE-Cube was added to the routine 3.0-T MR imaging protocol performed in 100 symptomatic patients (54 male patients with a median age of 32 years and 46 female patients with a median age of 33 years) who subsequently underwent arthroscopic knee surgery. All MR imaging studies were independently reviewed twice by two musculoskeletal radiologists. During the first review, the routine MR imaging protocol was used to detect cartilage lesions, ligament tears, meniscal tears, and bone marrow edema lesions. During the second review, FSE-Cube with multiplanar reformations was used to detect these joint abnormalities. With arthroscopic results as the reference standard, the sensitivity and specificity of FSE-Cube and the routine MR imaging protocol in the detection of cartilage lesions, anterior cruciate ligament tears, and meniscal tears were calculated. Permutation tests were used to compare sensitivity and specificity values. Results: FSE-Cube had significantly higher sensitivity (P = .039) but significantly lower specificity (P = .003) than the routine MR imaging protocol for detecting cartilage lesions. There were no significant differences (P = .183-.999) in sensitivity and specificity between FSE-Cube and the routine MR imaging protocol in the detection of anterior cruciate ligament tears, medial meniscal tears, or lateral meniscal tears. FSE-Cube depicted 96.2% of medial collateral ligament tears, 100% of lateral collateral ligament tears, and 85.3% of bone marrow edema lesions identified on images obtained with the routine MR imaging protocol. Conclusion: FSE-Cube has similar diagnostic performance as a routine MR imaging protocol for detecting cartilage lesions, cruciate ligament tears, collateral ligament tears, meniscal tears, and bone marrow edema lesions within the knee joint at 3.0 T. (C) RSNA, 2009
引用
收藏
页码:486 / 495
页数:10
相关论文
共 46 条
  • [31] Application of 3D Fast Spin-Echo T1 Black-Blood Imaging in the Diagnosis and Prognostic Prediction of Patients with Leptomeningeal Carcinomatosis
    Oh, J.
    Choi, S. H.
    Lee, E.
    Shin, D. J.
    Jo, S. W.
    Yoo, R-E.
    Kang, K. M.
    Yun, T. J.
    Kim, J-h
    Sohn, C-H
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (08) : 1453 - 1459
  • [32] Unenhanced calf MR angiography at 3.0 T using electrocardiography-gated partial-fourier fast spin echo imaging with variable flip angle
    Li, Dan
    Lin, Jiang
    Yan, Fuhua
    Wu, Qingyuan
    Lv, Weiwei
    San, Yan
    Yun, Hong
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (06) : 1311 - 1322
  • [33] Single-Slab 3D Fast Spin Echo Imaging: T1-Contrast Perspective
    Park, Jaeseok
    [J]. INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2023, 27 (03) : 121 - 132
  • [34] Comparison of 3D vs. 2D fast spin echo imaging for evaluation of articular cartilage in the knee on a 3 T system scientific research
    Milewski, Matthew D.
    Smitaman, Edward
    Moukaddam, Hicham
    Katz, Lee D.
    Essig, David A.
    Medvecky, Michael J.
    Haims, Andrew H.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1637 - 1643
  • [35] Endometrial cancer: preoperative staging using three-dimensional T2-weighted turbo spin-echo and diffusion-weighted MR imaging at 3.0 T: a prospective comparative study
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Imaoka, Izumi
    Kagawa, Yuki
    Murakami, Takamichi
    Nakamoto, Atsushi
    Ueguchi, Takashi
    Tatsumi, Mitsuaki
    Enomoto, Takayuki
    Kimura, Tadashi
    Tomiyama, Noriyuki
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (08) : 2296 - 2305
  • [36] Uterine cervical carcinoma: a comparison of two- and three-dimensional T2-weighted turbo spin-echo MR imaging at 3.0 T for image quality and local-regional staging
    Shin, Y. R.
    Rha, S. E.
    Choi, B. G.
    Oh, S. N.
    Park, M. Y.
    Byun, J. Y.
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (04) : 1150 - 1157
  • [37] MS Lesions Are Better Detected with 3D T1 Gradient-Echo Than with 2D T1 Spin-Echo Gadolinium-Enhanced Imaging at 3T
    Crombe, A.
    Saranathan, M.
    Ruet, A.
    Durieux, M.
    de Roquefeuil, E.
    Ouallet, J. C.
    Brochet, B.
    Dousset, V.
    Tourdias, T.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 501 - 507
  • [38] Fast volumetric spatial-spectral MR imaging of hyperpolarized 13C-labeled compounds using multiple echo 3D bSSFP
    Perman, William H.
    Bhattacharya, Pratip
    Leupold, Jochen
    Lin, Alexander P.
    Harris, Kent C.
    Norton, Valerie A.
    Hoevener, Jan-Bernd
    Ross, Brian D.
    [J]. MAGNETIC RESONANCE IMAGING, 2010, 28 (04) : 459 - 465
  • [39] Cranial nerve assessment in cavernous sinus tumors with contrast-enhanced 3D fast-imaging employing steady-state acquisition MR imaging
    Amemiya, Shiori
    Aoki, Shigeki
    Ohtomo, Kuni
    [J]. NEURORADIOLOGY, 2009, 51 (07) : 467 - 470
  • [40] Contrast-enhanced, ultrafast 3D pulmonary MR angiography in a single breath-hold: Initial assessment of imaging performance
    Steiner, P
    McKinnon, GC
    Romanowski, B
    Goehde, SC
    Hany, T
    Debatin, JF
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) : 177 - 182