Knee Joint: Comprehensive Assessment with 3D Isotropic Resolution Fast Spin-Echo MR Imaging-Diagnostic Performance Compared with That of Conventional MR Imaging at 3.0 T

被引:208
|
作者
Kijowski, Richard [1 ]
Davis, Kirkland W. [1 ]
Woods, Michael A. [1 ]
Lindstrom, Mary J. [2 ]
De Smet, Arthur A. [1 ]
Gold, Garry E. [3 ,4 ,5 ]
Busse, Reed F. [6 ]
机构
[1] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Clin Sci Ctr E3 311, Dept Biostat, Madison, WI 53792 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Orthoped Surg, Stanford, CA 94305 USA
[6] GE Healthcare, Global Appl Sci Lab, Madison, WI USA
关键词
GRADING ARTICULAR-CARTILAGE; MENISCAL TEARS; MULTIPLANAR RECONSTRUCTION; ARTHROSCOPIC CORRELATION; LIGAMENT; SEQUENCES; LESIONS; EXPERIENCE; ACCURACY; ANTERIOR;
D O I
10.1148/radiol.2523090028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether a three-dimensional isotropic resolution fast spin-echo sequence (FSE-Cube) has similar diagnostic performance as a routine magnetic resonance (MR) imaging protocol for evaluating the cartilage, ligaments, menisci, and osseous structures of the knee joint in symptomatic patients at 3.0 T. Materials and Methods: This prospective, HIPAA-compliant, institutional review board approved study was performed with a waiver of informed consent. FSE-Cube was added to the routine 3.0-T MR imaging protocol performed in 100 symptomatic patients (54 male patients with a median age of 32 years and 46 female patients with a median age of 33 years) who subsequently underwent arthroscopic knee surgery. All MR imaging studies were independently reviewed twice by two musculoskeletal radiologists. During the first review, the routine MR imaging protocol was used to detect cartilage lesions, ligament tears, meniscal tears, and bone marrow edema lesions. During the second review, FSE-Cube with multiplanar reformations was used to detect these joint abnormalities. With arthroscopic results as the reference standard, the sensitivity and specificity of FSE-Cube and the routine MR imaging protocol in the detection of cartilage lesions, anterior cruciate ligament tears, and meniscal tears were calculated. Permutation tests were used to compare sensitivity and specificity values. Results: FSE-Cube had significantly higher sensitivity (P = .039) but significantly lower specificity (P = .003) than the routine MR imaging protocol for detecting cartilage lesions. There were no significant differences (P = .183-.999) in sensitivity and specificity between FSE-Cube and the routine MR imaging protocol in the detection of anterior cruciate ligament tears, medial meniscal tears, or lateral meniscal tears. FSE-Cube depicted 96.2% of medial collateral ligament tears, 100% of lateral collateral ligament tears, and 85.3% of bone marrow edema lesions identified on images obtained with the routine MR imaging protocol. Conclusion: FSE-Cube has similar diagnostic performance as a routine MR imaging protocol for detecting cartilage lesions, cruciate ligament tears, collateral ligament tears, meniscal tears, and bone marrow edema lesions within the knee joint at 3.0 T. (C) RSNA, 2009
引用
收藏
页码:486 / 495
页数:10
相关论文
共 50 条
  • [1] Knee Derangements: Comparison of Isotropic 3D Fast Spin-Echo, Isotropic 3D Balanced Fast Field-Echo, and Conventional 2D Fast Spin-Echo MR Imaging
    Jung, Jin Young
    Yoon, Young Cheol
    Kim, Hye Rin
    Choe, Bong-Keun
    Wang, Joon Ho
    Jung, Jee Young
    RADIOLOGY, 2013, 268 (03) : 802 - 813
  • [2] Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee—image quality and diagnostic performance
    Oliver Ristow
    Lynne Steinbach
    Gregory Sabo
    Roland Krug
    Markus Huber
    Isabel Rauscher
    Ben Ma
    Thomas M. Link
    European Radiology, 2009, 19 : 1263 - 1272
  • [3] Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee-image quality and diagnostic performance
    Ristow, Oliver
    Steinbach, Lynne
    Sabo, Gregory
    Krug, Roland
    Huber, Markus
    Rauscher, Isabel
    Ma, Ben
    Link, Thomas M.
    EUROPEAN RADIOLOGY, 2009, 19 (05) : 1263 - 1272
  • [4] MR CHOLANGIOPANCREATOGRAPHY - FINDINGS ON 3D FAST SPIN-ECHO IMAGING
    SOTO, JA
    BARISH, MA
    YUCEL, EK
    FERRUCCI, JT
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) : 1397 - 1401
  • [5] Fast recovery 3D fast spin-echo MR imaging of the inner ear at 3 T
    Naganawa, S
    Koshikawa, T
    Fukatsu, H
    Ishigaki, T
    Aoki, I
    Ninomiya, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (02) : 299 - 302
  • [6] Rotator cuff: Evaluation with fast spin-echo versus conventional spin-echo MR imaging
    Carrino, JA
    McCauley, TR
    Katz, LD
    Smith, RC
    Lange, RC
    RADIOLOGY, 1997, 202 (02) : 533 - 539
  • [7] CONVENTIONAL AND FAST SPIN-ECHO MR-IMAGING - MINIMIZING ECHO TIME
    VINITSKI, S
    MITCHELL, DG
    EINSTEIN, SG
    RAO, VM
    FLANDERS, AE
    SCHWEITZER, ME
    LISTERUD, J
    SCHNALL, MD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (03): : 501 - 507
  • [8] Comparison of 3D Isotropic Resolution Fast Spin-Echo MRI with Conventional 2D MRI of Knee Ligaments and Menisci at 3.0T
    Subhas, N.
    Kao, A.
    Freire, M.
    Polster, J.
    Obuchowski, N.
    Winalski, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [9] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [10] Accelerating knee MR imaging: Compressed sensing in isotropic three-dimensional fast spin-echo sequence
    Lee, Seung Hyun
    Lee, Young Han
    Suh, Jin-Suck