Determination and interference studies of bismuth by tungsten trap hydride generation atomic absorption spectrometry

被引:35
作者
Kula, Ibrahim [1 ,2 ]
Arslan, Yasin [2 ,5 ]
Bakirdere, Sugin [2 ]
Titretir, Serap [3 ]
Kenduezler, Erdal [4 ]
Ataman, O. Yavuz [2 ]
机构
[1] Mugla Univ, Dept Chem, TR-48000 Mugla, Turkey
[2] Middle E Tech Univ, Dept Chem, TR-06531 Ankara, Turkey
[3] Inonu Univ, Dept Chem, TR-44280 Malatya, Turkey
[4] Ahi Evran Univ, Fac Educ, Dept Primary Educ, TR-40100 Kirsehir, Turkey
[5] Ataturk Univ, Dept Chem, TR-25240 Erzurum, Turkey
关键词
Interference; Bismuth; Tungsten trap; Hydride generation atomic absorption spectrometry (HGAAS); PLASMA-MASS SPECTROMETRY; SAMPLES; URINE; PALLADIUM; CADMIUM; COIL; LEAD; AAS;
D O I
10.1016/j.talanta.2009.06.084
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of bismuth requires sufficiently sensitive procedures for detection at the mu g L-1 level or lower. W-coil was used for on-line trapping of volatile bismuth species using HGAAS (hydride generation atomic absorption spectrometry); atom trapping using a W-coil consists of three steps. Initially BiH3 gas is formed by hydride generation procedure. The analyte species in vapor form are transported through the W-coil trap held at 289 degrees C where trapping takes place. Following the preconcentration step, the W-coil is heated to 1348 degrees C; analyte species are released and transported to flame-heated quartz atom cell where the atomic signal is formed. In our study, interferences have been investigated in detail during Bi determination by hydride generation, both with and without trap in the same HGAAS system. Interferent/analyte (mass/mass) ratio was kept at 1, 10 and 100. Experiments were designed for carrier solutions having 1.0 M HNO3. Interferents such as Fe, Mn, Zn, Ni, Cu, As, Se. Cd, Pb, Au, Na, Mg, Ca, chloride, sulfate and phosphate were examined. The calibration plot for an 8.0 ml. sampling volume was linear between 0.10 mu g L-1 and 10.0 mu g L-1 of Bi. The detection limit (3 s/m) was 25 ng L-1. The enhancement factor for the characteristic concentration (C-o) was found to be 21 when compared with the regular system without trap, by using peak height values. The validation of the procedure was performed by the analysis of the certified water reference material and the result was found to be in good agreement with the certified values at the 95% confidence level. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 12 条
[1]   Determination of bismuth, indium and lead in geological samples by electrothermal AAS Part 2. Comparative study of palladium and molybdenum containing chemical modifiers [J].
Acar, O ;
Turker, AR ;
Kilic, Z .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (06) :645-649
[2]   Determination of bismuth in urine and prescription medicines using atomic absorption with an on-line hydride generation system [J].
Cadore, S ;
dos Anjos, AP ;
Baccan, N .
ANALYST, 1998, 123 (08) :1717-1719
[3]   Determination of bismuth using on-line preconcentration by trapping on resistively heated W coil and hydride generation atomic absorption spectrometry [J].
Cankur, O ;
Ertas, N ;
Ataman, OY .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (06) :603-609
[4]   Determination of cadmium by flow injection atomic absorption spectrometry with cold vapor generation by a tetrahydroborate-form anion-exchanger [J].
Chuachuad, W ;
Tyson, JF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (04) :273-281
[5]  
Dedina J., 1995, HYDRIDE GENERATION A, V1st
[6]   In situ trapping of bismuthine in externally heated quartz tube atomizers for atomic absorption spectrometry [J].
Kratzer, J ;
Dedina, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (02) :208-210
[7]   Determination of bismuth in serum and urine by direct injection nebulization inductively coupled plasma mass spectrometry [J].
Li, HY ;
Keohane, BM ;
Sun, HZ ;
Sadler, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (10) :1111-1114
[8]  
MARROW A, 1997, ATOM SPECTROSC, V18, P23
[9]   Effects of bismuth contamination on the growth and activity of soil microorganisms using thiols as model compounds [J].
Murata, T .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2006, 41 (02) :161-172
[10]   Determination of bismuth in metallurgical materials using a quartz tube atomizer with tungsten coil and flow injection-hydride-generation atomic absorption spectrometry [J].
Ribeiro, AS ;
Arruda, MAZ ;
Cadore, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :2113-2120