FTIR-ATR Study of Water Uptake and Diffusion Through Ion-Selective Membranes Based on Plasticized Poly(vinyl chloride)

被引:77
作者
Lindfors, Tom [1 ]
Sundfors, Fredrik [1 ]
Hofler, Lajos [2 ]
Gyurcsanyi, Robert E. [2 ,3 ]
机构
[1] Abo Akad Univ, Proc Chem Ctr, Analyt Chem Lab, FI-20500 Turku, Finland
[2] Budapest Univ Technol & Econ, Dept Inorgan & Analyt Chem, H-1111 Budapest, Hungary
[3] Budapest Univ Technol & Econ, Hungarian Acad Sci, Res Grp Tech Analyt Chem, H-1111 Budapest, Hungary
关键词
Water uptake; Diffusion; FTIR-ATR; Plasticized poly(vinyl chloride); Ion-selective membranes; Membranes; Conducting materials; Finite-difference modeling; LOWER DETECTION LIMIT; SOLID-CONTACT; SPECTROSCOPIC ANALYSIS; CONDUCTING POLYMER; PVC-MEMBRANES; ELECTRODES; TRANSPORT; STATE; MICROSTRUCTURE; FLUXES;
D O I
10.1002/elan.200904609
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the water uptake and diffusion of water through ion-selective membranes based on plasticized poly(vinyl chloride) (PVC) have been studied by FTIR-ATR spectroscopy. The diffusion of water was modeled by the finite-difference method and the obtained diffusion coefficients are reported for membranes plasticized with bis(2-ethylhexyl) sebacate (DOS) and 2-nitrophenyl octyl ether (oNPOE). The influence of various common membrane additives such as lipophilic salts and ionophores on the water uptake was also determined through representative membrane formulations (potassium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate (KTFPB) and/or calcium ionophore IV (ETH 5234)). The best fits of the time dependent water concentration changes in the membrane upon water uptake were obtained with a model consisting of two diffusion coefficients describing fast (ca. 1.5 x 10(-7) cm(2) s(-1)) and slow (ca. 9.5 x 10(-9) cm(2) s(-1)) diffusion of water in the PVC membranes. In contrast to the water uptake of the membranes, the diffusion rates were found to be practically independent of the membrane composition. It is shown that KTFPB and ETH 5234 decrease the water uptake whereas it is facilitated by a higher plasticizer content of the membrane. Monomeric, dimeric, clustered and bulk water could be distinguished by deconvolution of the FTIR-ATR spectra, which is important for understanding the water uptake mechanism.
引用
收藏
页码:1914 / 1922
页数:9
相关论文
共 45 条
[11]   Microfabricated ISEs:: critical comparison of inherently conducting polymer and hydrogel based inner contacts [J].
Gyurcsányi, RE ;
Rangisetty, N ;
Clifton, S ;
Pendley, BD ;
Lindner, E .
TALANTA, 2004, 63 (01) :89-99
[12]   Direct evidence of ionic fluxes across ion selective membranes:: A scanning electrochemical microscopic and potentiometric study [J].
Gyurcsányi, RE ;
Pergel, E ;
Nagy, R ;
Kapui, I ;
Lan, BTT ;
Tóth, K ;
Bitter, I ;
Lindner, E .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :2104-2111
[13]  
Harrick N.J., 1967, INTERNAL REFLECTION
[14]  
KALAOUZIS PJ, 1993, PACKING TECHNOL SCI, V6, P261
[15]   FTIR-ATR SPECTROSCOPIC ANALYSIS OF BIS-CROWN ETHER BASED PVC-MEMBRANES .2. THE DIFFUSION BEHAVIOR OF K+-COMPLEXES IN THE SYSTEM OF PVC DIOCTYLSEBACATE CROWN-ETHER BME-44 - EX-SITU-STUDIES ON DRIED MEMBRANES [J].
KELLNER, R ;
ZIPPEL, E ;
PUNGOR, E ;
TOTH, K ;
LINDNER, E .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 328 (06) :464-468
[16]   FTIR-ATR SPECTROSCOPIC ANALYSIS OF BIS-CROWN-ETHER BASED PVC-MEMBRANE SURFACES [J].
KELLNER, R ;
FISCHBOCK, G ;
GOTZINGER, G ;
PUNGOR, E ;
TOTH, K ;
POLOS, L ;
LINDNER, E .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 322 (02) :151-156
[17]   The influence of the conditioning procedure on potentiometric characteristics of solid contact calcium-selective electrodes in nanomolar concentration solutions [J].
Konopka, Anna ;
Sokalski, Tomasz ;
Lewenstam, Andrzej ;
Maj-Zurawska, Magdalena .
ELECTROANALYSIS, 2006, 18 (22) :2232-2242
[18]   A NOVEL SPECTROSCOPIC METHOD TO IMAGE H2O DISTRIBUTION IN ION-SELECTIVE MEMBRANES [J].
LI, XZ ;
PETROVIC, S ;
HARRISON, DJ .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :275-280
[19]   Dual-sorption model of water uptake in poly(vinyl chloride)-based ion-selective membranes: Experimental water concentration and transport parameters [J].
Li, Z ;
Li, XZ ;
Petrovic, S ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (10) :1717-1725
[20]   Comparison of numerical modeling of water uptake in poly(vinyl chloride)-based ion-selective membranes with experiment [J].
Li, Z ;
Li, XZ ;
Rothmaier, M ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1996, 68 (10) :1726-1734