Activated carbon load equalization of transient concentrations of gas-phase toluene: Effect of gas flow rate during pollutant non-loading intervals

被引:20
作者
Nabatilan, Marilou M. [1 ]
Harhad, Ameziane [2 ]
Wolenski, Peter R. [2 ]
Moe, William M. [1 ]
机构
[1] Louisiana State Univ, Dept Civil & Environm Engn, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Dept Math, Baton Rouge, LA 70803 USA
关键词
Attenuation; Biofilter; Dampen; Equalization; GAC; Flow rate; Toluene; Unsteady-state; FUNGAL BIOFILTER; AIR EMISSIONS; ALPHA-PINENE; PERFORMANCE; BIOFILTRATION; VAPOR; MIXTURES; ADSORPTION; STRATEGY; DESIGN;
D O I
10.1016/j.cej.2009.11.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dynamically varying contaminant concentrations pose a challenge in the design and operation of biofilters for air pollution control. One strategy for managing this problem involves installation of a column packed with granular activated carbon (GAC) to achieve load equalization prior to biofilter treatment. Research described here was conducted to evaluate the effect of changes in gas flow rates during contaminant non-loading intervals on the GAC load equalization process. Toluene served as the model pollutant, and BPL 4 x 6 mesh GAC served as the model adsorbent. Fixed-bed adsorption/desorption experiments were conducted with influent toluene concentrations of 250ppm(v) (superficial gas velocity 300m/h) for durations of 12, 8, and 4h/day, and no toluene in the influent air for the remainder of the day to simulate processes with varying work schedules. During toluene non-loading intervals, experiments were conducted with gas flow rates 1.0, 0.50, and 0.10 times the flow rate during toluene loading intervals. Numerical simulations performed using a pore and surface diffusion model, adapted to account for changes in gas flow rate, were in close agreement with experimental measurements. Collectively, experimental data and model simulations demonstrated that relatively small GAC columns (empty bed contact times on the order of a few seconds) can achieve considerable load equalization even when gas flow rates are reduced during contaminant non-loading intervals. Results suggest that in cases where the fraction of time pollutants present in the gas stream are relatively small, use of a passively operated GAC load equalization process in conjunction with reduction in gas flow rates during contaminant non-loading intervals may prove especially attractive. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:339 / 347
页数:9
相关论文
共 30 条
[1]   Treatment of MEK and toluene mixtures in biofilters: Effect of operating strategy on performance during transient loading [J].
Atoche, JC ;
Moe, WM .
BIOTECHNOLOGY AND BIOENGINEERING, 2004, 86 (04) :468-481
[2]   Effect of starvation on the performance and re-acclimation of biotrickling filters for air pollution control [J].
Cox, HHJ ;
Deshusses, MA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (14) :3069-3073
[3]   TRANSPORT OF ORGANIC-COMPOUNDS WITH SATURATED GROUNDWATER-FLOW - MODEL DEVELOPMENT AND PARAMETER SENSITIVITY [J].
CRITTENDEN, JC ;
HUTZLER, NJ ;
GEYER, DG ;
ORAVITZ, JL ;
FRIEDMAN, G .
WATER RESOURCES RESEARCH, 1986, 22 (03) :271-284
[4]  
Devinny J.S., 1999, Biofiltration for Air Pollution Control
[5]   Biofiltration of cyclic air emissions of α-pinene at low and high frequencies [J].
Dirk-Faitakis, C ;
Allen, DG .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2003, 53 (11) :1373-1383
[6]  
FRIEDMAN G, 1984, THESIS MICHIGAN TECH
[7]   Predicting the performance of fixed-bed granular activated carbon adsorbers [J].
Hand, DW ;
Crittenden, JC ;
Hokanson, DR ;
Bulloch, JL .
WATER SCIENCE AND TECHNOLOGY, 1997, 35 (07) :235-241
[8]   Concomitant Adsorption and Desorption of Organic Vapor in Dry and Humid Air Streams using Microwave and Direct Electrothermal Swing Adsorption [J].
Hashisho, Zaher ;
Emamipour, Hamidreza ;
Rood, Mark J. ;
Hay, K. James ;
Kim, Byung J. ;
Thurston, Deborah .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (24) :9317-9322
[9]   Integrated treatment scheme of a biofilter preceded by a two-bed cyclic adsorption unit treating dynamic toluene loading [J].
Kim, Daekeun ;
Cai, Zhangli ;
Sorial, George A. ;
Shin, Heungsoo ;
Knaebel, Kent .
CHEMICAL ENGINEERING JOURNAL, 2007, 130 (01) :45-52
[10]   Activated carbon load equalization of discontinuously generated acetone and toluene mixtures treated by biofiltration [J].
Li, CN ;
Moe, WM .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (07) :2349-2356