Silica removal from Mokai, New Zealand, geothermal brine by treatment with lime and a cationic precipitant

被引:24
作者
Ueda, A
Kato, K
Mogi, K
Mroczek, E
Thain, IA
机构
[1] Inst Geol & Nucl Sci, Wairakei Res Ctr, Taupo, New Zealand
[2] Tech Serv Ltd, Geothermal & Energy, Taupo, New Zealand
关键词
silica; scale; removal; CaO; Mokai; New Zealand;
D O I
10.1016/S0375-6505(02)00050-0
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Preliminary experiments using two chemicals (CaO, a quicklime, and a cationic nitrogen-bearing precipitant, EC-004) to remove silica from geothermal brine were undertaken at the Mokai geothermal plant, New Zealand. The brine was mixed with the reagent (CaO or EC-004). The reaction was studied from the start of the experiment (NRT, 0 min, no retaining time) and after 15 min (15RT) at 90 degreesC. The concentration of silica in the brine was initially 954 mg/l, and decreased linearly with increasing reagent concentration. When CaO is added, the silica concentration at 15RT was 200 mg/l lower than at NRT and became almost zero on addition of 1.5 g/l. In contrast, when EC-004 is added, the total silica concentration nearly reaches the solubility of amorphous silica at 90 degreesC. In order to prevent silica scaling in Mokai brines cooled to 90 degreesC, the CaO and EC-004 added should be individually adjusted to 0.5 g/l and 80 mg/l, respectively. (C) 2002 CNR. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:47 / 61
页数:15
相关论文
共 25 条
[1]  
ABE S, 1997, J JPN GEOTHERM ENERG, V34, P248
[2]  
Featherstone J. L., 1989, US Patent, Patent No. [4,429,535, 4429535]
[3]   CALCULATION OF AMORPHOUS SILICA SOLUBILITIES AT 25-DEGREES-C TO 300-DEGREES-C AND APPARENT CATION HYDRATION NUMBERS IN AQUEOUS SALT-SOLUTIONS USING THE CONCEPT OF EFFECTIVE DENSITY OF WATER [J].
FOURNIER, RO ;
MARSHALL, WL .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1983, 47 (03) :587-596
[4]  
FURUKAWA T, 1995, J GEOTHERM RES SOC J
[5]  
GALLUP DL, 1997, GEOTHERMAL RESOURCES, V21, P399
[6]  
Gallup DL., 1997, GEOTHERM RESOUR COUN, V21, P49
[7]  
Gudmundsson SR, 1989, GEOTHERMICS, V18, P105
[8]  
HAGA D, J JPN GEOTHERM SOC, V24, P237
[9]   Scale prevention method by brine acidification with biochemical reactors [J].
Hirowatari, K .
GEOTHERMICS, 1996, 25 (02) :259-270
[10]  
HIROWATARI K, 1997, GEOTHERM RES COUNCIL, V21, P55