JITTER RECORDINGS WITH CONCENTRIC NEEDLE ELECTRODES

被引:98
作者
Stalberg, Erik V. [1 ]
Sanders, Donald B. [2 ]
机构
[1] Univ Hosp, Dept Clin Neurophysiol, S-75185 Uppsala, Sweden
[2] Duke Univ, Med Ctr, Div Neurol, Durham, NC 27710 USA
关键词
jitter; neuromuscular transmission; SFEMG; concentric needle electrode; EMG; SINGLE-FIBER ELECTROMYOGRAPHY; EXTENSOR-DIGITORUM-COMMUNIS; UNIT ACTION-POTENTIALS; MYASTHENIA-GRAVIS; MACRO EMG; VALUES; MINIMONOGRAPH;
D O I
10.1002/mus.21424
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Neuromuscular jitter is generally recorded with a single fiber (SF) electromyography (EMG) electrode. Due to concern about using reusable needle electrodes, an acceptable alternative for the SF electrode has been sought. This is a review of the issues involved in using disposable concentric needle (CN) electrodes to measure jitter. Signals recorded with CN electrodes frequently represent the summation of many single fiber action potentials, which will decrease the apparent jitter. The influence of these artifacts on the final result also depends on the analysis method. Reference values obtained with CN electrodes correlate with SF EMG values, but they are a few microseconds lower. Overall results show that the CN method is a good alternative to SFEMG and will facilitate the use of jitter analysis. The results must be interpreted with caution, particularly in borderline cases, but they may be acceptable for clinical use when SF electrodes cannot be used. Muscle Nerve 40: 331-339, 2009
引用
收藏
页码:331 / 339
页数:9
相关论文
共 27 条
[1]   Concentric-needle single-fiber electromyography for the diagnosis of myasthenia gravis [J].
Benatar, Michael ;
Hammad, Mustafa ;
Doss-Riney, Heidi .
MUSCLE & NERVE, 2006, 34 (02) :163-168
[2]  
Clarke S., 1985, NEUROLOGY, V35, pS1
[3]  
Ertas M, 2000, MUSCLE NERVE, V23, P715
[4]  
GILCHRIST JM, 1992, MUSCLE NERVE, V15, P151
[5]  
King JC, 1997, MUSCLE NERVE, V20, P1525, DOI 10.1002/(SICI)1097-4598(199712)20:12<1525::AID-MUS7>3.0.CO
[6]  
2-A
[7]   Concentric needle single fiber electromyography:: Comparative jitter on voluntary-activated and stimulated Extensor Digitorum Communis [J].
Kouyoumdjian, Joao Aris ;
Stalberg, Erik V. .
CLINICAL NEUROPHYSIOLOGY, 2008, 119 (07) :1614-1618
[8]   Reference jitter values for concentric needle electrodes in voluntarily activated extensor digitorum communis and orbicularis oculi muscles [J].
Kouyoumdjian, Joao Aris ;
Stalberg, Erik V. .
MUSCLE & NERVE, 2008, 37 (06) :694-699
[9]   Concentric needle single fiber electromyography -: Normative jitter values on voluntary activated Extensor Digitorum Communis [J].
Kouyoumdjian, Joao Aris ;
Stalberg, Erik V. .
ARQUIVOS DE NEURO-PSIQUIATRIA, 2007, 65 (2B) :446-449