Dose rate dependence of the PTW 60019 microDiamond detector in high dose-per-pulse pulsed beams

被引:18
|
作者
Brualla-Gonzalez, Luis [1 ]
Gomez, Faustino [2 ,3 ]
Pombar, Miguel [2 ,4 ]
Pardo-Montero, Juan [2 ,4 ]
机构
[1] Hosp Gen Univ Valencia, Serv Radiofis, ERESA, Valencia 46014, Spain
[2] Inst Invest Sanitaria IDIS, Grp Imaxe Mol, Santiago De Compostela, Spain
[3] Univ Santiago de Compostela, Dept Fis Particulas, Santiago De Compostela, Spain
[4] Univ Santiago de Compostela, Serv Radiofis & Protecc Radiol, Complexo Hosp, Santiago De Compostela, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 01期
关键词
diamond detector; recombination; microdiamond; dose-per-pulse; SYNTHETIC DIAMOND DETECTORS; IONIZATION-CHAMBER; DOSIMETRIC CHARACTERIZATION; RELATIVE DOSIMETRY; PHOTON; DIODE; DENSITY; VERIFICATION; PROTOTYPE; DEFECTS;
D O I
10.1088/0031-9155/61/1/N11
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recombination effects can affect the detectors used for the dosimetry of radiotherapy fields. They are important when using ionization chambers, especially in liquid-filled ionization chambers, and should be corrected for. The introduction of flattening-filter-free accelerators increases the typical dose-per-pulse used in radiotherapy beams, which leads to more important recombination effects. Diamond detectors provide a good solution for the dosimetry and quality assurance of small radiotherapy fields, due to their low energy dependence and small volume. The group of Universita di Roma Tor Vergata has developed a synthetic diamond detector, which is commercialized by PTW as microDiamond detector type 60019. In this work we present an experimental characterization of the collection efficiency of the microDiamond detector, focusing on high dose-per-pulse FFF beams. The collection efficiency decreases with dose-per-pulse, down to 0.978 at 2.2 mGy/pulse, following a Fowler-Attix-like curve. On the other hand, we have found no significant dependence of the collection efficiency on the pulse repetition frequency (or pulse period).
引用
收藏
页码:N11 / N19
页数:9
相关论文
共 50 条
  • [1] Dose rate dependence of the PTW 60019 microDiamond detector in high dose-per-pulse pulsed beams
    Pardo-Montero, J.
    Brualla-Gonzalez, L.
    Gomez, F.
    Pombar, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S375 - S375
  • [2] LET dependence of the PTW-60019 microDiamond detector response in particle beams
    Rossomme, S.
    Delor, A.
    Hopfgartner, J.
    Denis, J.
    Vynckier, S.
    Palmans, H.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S692 - S692
  • [3] Characterization of a microDiamond detector in high-dose-per-pulse electron beams for intra operative radiation therapy
    Di Venanzio, C.
    Marinelli, Marco
    Tonnetti, A.
    Verona-Rinati, G.
    Falco, M. D.
    Pimpinella, M.
    Ciccotelli, A.
    De Stefano, S.
    Felici, G.
    Marangoni, F.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 897 - 902
  • [4] Output factor measurement in high dose-per-pulse IORT electron beams
    Pimpinella, M.
    Andreoli, S.
    De Angelis, C.
    Della Monaca, S.
    D'Arienzo, M.
    Menegotti, L.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 94 - 102
  • [5] LET dependence of the response of a PTW-60019 microDiamond detector in a 62 MeV proton beam
    Rossomme, S.
    Denis, J. M.
    Souris, K.
    Delor, A.
    Bartier, F.
    Dumont, D.
    Vynckier, S.
    Palmans, H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (09): : 1135 - 1138
  • [6] Ion recombination correction for very high dose-per-pulse high-energy electron beams
    Di Martino, F
    Giannelli, M
    Traino, AC
    Lazzeri, M
    MEDICAL PHYSICS, 2005, 32 (07) : 2204 - 2210
  • [7] Dosimetry of Ultra-Short High Dose-Per-Pulse Very High Energy Electron Beams
    McManus, M.
    Romano, F.
    Lee, N.
    Wilfrid, F.
    Antonio, G.
    Royle, Gary
    Palmans, H.
    Subiel, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E372 - E372
  • [8] A semi-analytical calculation of the recombination correction factor in high dose-per-pulse beams.
    Bancheri, Julien
    Seuntjens, Jan
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3368 - S3370
  • [9] Ion collection efficiency of ionization chambers in ultra-high dose-per-pulse electron beams
    Kranzer, Rafael
    Poppinga, Daniela
    Weidner, Jan
    Schueller, Andreas
    Hackel, Thomas
    Looe, Hui Khee
    Poppe, Bjoern
    MEDICAL PHYSICS, 2021, 48 (02) : 819 - 830
  • [10] PTW-diamond detector: Dose rate and particle type dependence
    Fidanzio, A
    Azario, L
    Miceli, R
    Russo, A
    Piermattei, A
    MEDICAL PHYSICS, 2000, 27 (11) : 2589 - 2593