FIESTA-ET: High-resolution cardiac imaging using echo-planar steady-state free precession

被引:28
作者
Slavin, GS [1 ]
Saranathan, M [1 ]
机构
[1] Gen Elect Med Syst, Waukesha, WI USA
关键词
heart; MR; magnetic resonance; echo-planar; cine study; rapid imaging;
D O I
10.1002/mrm.10321
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work describes a technique that combines multishot echo-planar imaging (EPI) with steady-state free precession (SSFP, also known as TrueFISP, FIESTA, and balanced FFE) for multislice, cine MR imaging of the heart. Unlike recently reported methods, the technique presented here (FIESTA-ET) is high-resolution and does not require off line reconstruction or post-processing. It is therefore suitable for use on standard clinical scanners. FIESTA-ET was compared with conventional FIESTA imaging in 10 volunteers and quantitative analyses of myocardial signal-to-noise ratios (SNR) and ventricular volumes were performed. While providing comparable image quality, FIESTA-ET required half the acquisition time per slice of conventional FIESTA. Because multiple slices could be imaged in a single breathhold, the entire heart could be scanned in less than 2 min. Although the FIESTA-ET images exhibited an unexpected increase (P < 0.0005) in myocardial SNR of 16% over FIESTA, the volumetric measurements showed excellent correlation.
引用
收藏
页码:934 / 941
页数:8
相关论文
共 34 条
  • [1] MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
    Barkhausen, J
    Ruehm, SG
    Goyen, M
    Buck, T
    Laub, G
    Debatin, JF
    [J]. RADIOLOGY, 2001, 219 (01) : 264 - 269
  • [2] BARKHAUSEN J, 2001, P 9 ANN M ISMRM GLAS, P1885
  • [3] INTERLEAVED ECHO-PLANAR IMAGING ON A STANDARD MRI SYSTEM
    BUTTS, K
    RIEDERER, SJ
    EHMAN, RL
    THOMPSON, RM
    JACK, CR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) : 67 - 72
  • [4] ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING
    BUTTS, K
    RIEDERER, SJ
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 285 - 293
  • [5] Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    Carr, JC
    Simonetti, O
    Bundy, J
    Li, DB
    Pereles, S
    Finn, JP
    [J]. RADIOLOGY, 2001, 219 (03) : 828 - 834
  • [6] THEORETICAL ASPECTS OF MOTION SENSITIVITY AND COMPENSATION IN ECHO-PLANAR IMAGING
    DUERK, JL
    SIMONETTI, OP
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06): : 643 - 650
  • [7] Epstein FH, 1999, MAGNET RESON MED, V41, P609, DOI 10.1002/(SICI)1522-2594(199903)41:3<609::AID-MRM25>3.0.CO
  • [8] 2-2
  • [9] Epstein FH, 2000, JMRI-J MAGN RESON IM, V11, P75, DOI 10.1002/(SICI)1522-2586(200002)11:2<75::AID-JMRI1>3.0.CO
  • [10] 2-P