The Malleable Implant Salvage Technique: Infection Outcomes after Mulcahy Salvage Procedure and Replacement of Infected Inflatable Penile Prosthesis with Malleable Prosthesis

被引:54
|
作者
Gross, Martin S. [1 ]
Phillips, Elizabeth A. [1 ]
Balen, Alejandra [1 ]
Eid, J. Francois [2 ]
Yang, Christopher [3 ]
Simon, Ross [3 ]
Martinez, Daniel [3 ]
Carrion, Rafael [3 ]
Perito, Paul [4 ]
Levine, Laurence [5 ]
Greenfield, Jason [6 ]
Munarriz, Ricardo [1 ]
机构
[1] Boston Univ, Med Ctr, Boston, MA 02118 USA
[2] Adv Urol Care, New York, NY USA
[3] USF Morsani Coll Med, Tampa, FL USA
[4] Perito Urol, Coral Gables, FL USA
[5] Rush Med Coll, Chicago, IL 60612 USA
[6] Urol Associates North Texas, Arlington, TX USA
关键词
penile prosthesis; salvage therapy; infection; erectile dysfunction; ERECTILE DYSFUNCTION; MANAGEMENT;
D O I
10.1016/j.juro.2015.08.091
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Since its introduction in 1996 Mulcahy salvage has significantly improved outcomes for the removal and replacement of infected inflatable penile prostheses. Long-term followup data of Mulcahy salvage show an infection-free rate of 82%. A multicenter retrospective analysis of the malleable implant salvage technique was conducted to assess infection outcomes and the feasibility of conversion from malleable device back to inflatable penile prosthesis. Materials and Methods: This is a retrospective, institutional review board exempt, multi-institution study of 58 patients who underwent Mulcahy salvage with inflatable penile prosthesis removal and replacement with malleable prosthesis. Patient operative notes and charts were extensively reviewed to compile study data. Results: Between 2002 and 2014 a total of 58 patients underwent infected inflatable penile prosthesis removal and replacement with a malleable prosthesis via Mulcahy salvage. Of these patients 54 (93%) have remained infection-free postoperatively. Average patient age was 56.4 years and average operative time was 148 minutes. Postoperative followup (as of May 2015) ranged from 1 month to 84 months. Of the 54 patients 37 retained the malleable prosthesis and 17 (31%) subsequently underwent replacement with an inflatable penile prosthesis. This occurred on average 6.7 months after Mulcahy salvage. Four patients had persistent infection after Mulcahy salvage with the malleable prosthesis and underwent explantation. Conclusions: This retrospective analysis of Mulcahy salvage procedure and replacement of inflatable penile prosthesis with malleable prosthesis shows a high infection-free rate. Additionally, 17 of the 54 patients who remained infection-free were able to successfully undergo subsequent removal of the malleable prosthesis and replacement with an inflatable penile prosthesis. Further prospective studies are needed to compare salvage with malleable vs inflatable penile prosthesis.
引用
收藏
页码:694 / 697
页数:4
相关论文
共 38 条
  • [22] Hypertension and low cholesterol as risk factors for infection after primary inflatable penile prosthesis surgery
    Loloi, Justin
    Matloubieh, Jubin
    Riley, Catie
    Babar, Mustufa
    Melendez, David
    Watts, Kara
    Maria, Pedro
    JOURNAL OF MENS HEALTH, 2022, 18 (06)
  • [23] Comparison of a New Length Measurement Technique for Inflatable Penile Prosthesis Implantation to Standard Techniques: Outcomes and Patient Satisfaction
    Henry, Gerard
    Houghton, Laura
    Culkin, Daniel
    Otheguy, Juan
    Shabsigh, Ridwan
    Ohl, Dana A.
    JOURNAL OF SEXUAL MEDICINE, 2011, 8 (09) : 2640 - 2646
  • [24] Surgical technique to maintain penile length after insertion of an inflatable penile prosthesis via infrapubic approach
    Borges, F
    Hakim, L
    Kline, C
    JOURNAL OF SEXUAL MEDICINE, 2006, 3 (03) : 550 - 553
  • [25] 3-Piece Inflatable Penile Prosthesis Placement Following Radical Cystoprostatectomy and Urinary Diversion: Technique and Outcomes
    Loh-Doyle, Jeffrey
    Patil, Mukul B.
    Sawkar, Hari
    Wayne, Kevin
    Boyd, Stuart D.
    JOURNAL OF SEXUAL MEDICINE, 2018, 15 (06) : 907 - 913
  • [26] Long-Term Infection Outcomes After Original Antibiotic Impregnated Inflatable Penile Prosthesis Implants: Up to 7.7 Years of Followup
    Carson, Culley C., III
    Mulcahy, John J.
    Harsch, Manya R.
    JOURNAL OF UROLOGY, 2011, 185 (02) : 614 - 618
  • [27] Cylinder rerouting for lateral extrusion after inflatable penile prosthesis implantation - Surgical technique revision
    Pinto Pe Leve, Paulo Jorge
    Cardoso Felicio, Joao Pedro
    de Oliveira, Pedro Simoes
    Palma dos Reis, Jose Manuel
    Estrocio Martins, Francisco Alves
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2020, 92 (03) : 271 - 272
  • [28] Clinical outcomes and patient satisfaction rates among elderly male aged ≥75 years with inflatable penile prosthesis implant for medically refractory erectile dysfunction
    Eric Chung
    Matt Solomon
    Ling DeYoung
    Gerald B. Brock
    World Journal of Urology, 2014, 32 : 173 - 177
  • [29] Clinical outcomes and patient satisfaction rates among elderly male aged ≥75 years with inflatable penile prosthesis implant for medically refractory erectile dysfunction
    Chung, Eric
    Solomon, Matt
    DeYoung, Ling
    Brock, Gerald B.
    WORLD JOURNAL OF UROLOGY, 2014, 32 (01) : 173 - 177
  • [30] Partial-limb Salvage After Persistent Infection in the Distal Femoral Prosthesis: Straight-plasty - a Novel Technique
    Kundu, Zile Singh
    Gupta, Vinay
    Gogna, Paritosh
    Sangwan, Sukhbir Singh
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2014, 24 (03): : 213 - 215