Design considerations for silicon sensors for use in catheters and guide wires

被引:12
作者
Goosen, JFL [1 ]
机构
[1] Delft Univ Technol, Dept Engn Mech, Struct Optimisat & Computat Mech Grp, NL-2628 CD Delft, Netherlands
关键词
D O I
10.1088/0964-1726/11/5/328
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A growing field of application for micro-electromechanical systems is the medical field of minimally invasive interventions. These procedures use catheters and guide wires, inserted into the blood vessels, to reach places deep inside the body, without the need for open surgery. This reduces recovery time and discomfort to the patient, operating time and the risks involved with general anaesthetics. For proper diagnosis and monitoring treatment, more information is needed; silicon sensors for catheters and guide wires have been developed to obtain this information. As the accurate positioning of these instruments is problematic, it is desirable to combine several sensors on the same instrument to measure several parameters at the same location. However, there are many considerations in designing silicon sensors for this application, such as small size, low power consumption, biocompatibility of materials, patient safety, a limited number of connections, packaging, survivability of the sensor during use, etc. This paper will discuss the design considerations of micromachined (silicon) sensors and actuators for use in catheters and guide wires. As an example, a multiparameter blood sensor, measuring flow velocity, pressure and oxygen saturation, will be discussed.
引用
收藏
页码:804 / 812
页数:9
相关论文
共 10 条
[1]   Thermal flow sensor for liquids and gases based on combinations of two principles [J].
Ashauer, M ;
Glosch, H ;
Hedrich, F ;
Hey, N ;
Sandmaier, H ;
Lang, W .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 73 (1-2) :7-13
[2]  
GAISEANU F, 1998, P EUROSENSORS, V13, P43
[3]   Bipolar-compatible epitaxial poly for smart sensors: stress minimization and applications [J].
Gennissen, PTJ ;
Bartek, M ;
French, PJ ;
Sarro, PM .
SENSORS AND ACTUATORS A-PHYSICAL, 1997, 62 (1-3) :636-645
[4]  
GOOSEN J, 1999, P SMIT CIMIT BOST MA
[5]  
Goosen J. F. L., 2000, Proceedings IEEE Thirteenth Annual International Conference on Micro Electro Mechanical Systems (Cat. No.00CH36308), P537, DOI 10.1109/MEMSYS.2000.838574
[6]  
Goosen JFL, 1999, P SOC PHOTO-OPT INS, V3876, P38, DOI 10.1117/12.360501
[7]  
GOOSEN JFL, 2000, P MICR EUR MME 2000, pB8
[8]   Low power integrated pressure sensor system for medical applications [J].
Hierold, C ;
Clasbrummel, B ;
Behrend, D ;
Scheiter, T ;
Steger, M ;
Oppermann, K ;
Kapels, H ;
Landgraf, E ;
Wenzel, D ;
Etzrodt, D .
SENSORS AND ACTUATORS A-PHYSICAL, 1999, 73 (1-2) :58-67
[9]   An invasive catheter flow sensor with on-chip CMOS readout electronics for the on-line determination of blood flow [J].
Kersjes, R ;
Lienscher, F ;
Spiegel, E ;
Manoli, Y ;
Mokwa, W .
SENSORS AND ACTUATORS A-PHYSICAL, 1996, 54 (1-3) :563-567
[10]   DIMES-01, A BASE-LINE BIFET PROCESS FOR SMART SENSOR EXPERIMENTATION [J].
NANVER, LK ;
GOUDENA, EJG ;
VANZEIJL, HW .
SENSORS AND ACTUATORS A-PHYSICAL, 1993, 36 (02) :139-147