Continuous recording of pulmonary artery diastolic pressure and cardiac output using a novel ultrasound transducer

被引:9
作者
Chandraratna, PAN
Brar, R
Vijayasekaran, S
Chen, QX
Niguse, GT
Shaikh, Y
Cho, HD
机构
[1] Div Cardiol Los Angeles Cty, Los Angeles, CA USA
[2] Univ So Calif, Med Ctr, Los Angeles, CA USA
关键词
D O I
10.1067/mje.2002.125921
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The feasibility of hands-free transthoracic continuous determination of pulmonary artery (PA) diastolic pressure (PAD) and cardiac output (CO) by Doppler ultrasound has not been previously demonstrated. We developed a 2.5-MHz spherical transducer mounted in an external housing to permit steering in 360 degrees (Contison). The external housing was attached to the chest wall using an adhesive patch. Methods and Results: Fifty patients in the coronary care department who had PA catheters had Doppler ultrasound studies. The 2.5-MHz spherical transducer was placed at the left sternal border to permit imaging of the pulmonic valve and was attached to a commercial ultrasound machine. The PA was imaged and its diameter measured. The pulmonary flow velocity signal was recorded and the time velocity integral obtained. The CO was calculated as: CO = time velocity integral of the PA systolic flow velocity signal x pi diameter(2) divided by 4 x heart rate. The pulmonary regurgitation signal was then recorded and the end-diastolic velocity of the regurgitant signal was measured. Right atrial pressure was assessed from the jugular venous pressure or from the size and pulsatility of the inferior vena cava. The PADP was calculated as: PADP = 4 end-diastolic velocity of the regurgitant signal(2) + right atrial pressure. The CO, PADP, and pulmonary wedge pressure were recorded from the PA catheter immediately after the ultrasound studies. Serial data were obtained every half hour or 1 hour up to a maximum of 5 hours. Adequate Doppler signals were obtained in 43 patients. Results. There was a good correlation between the PADP by Doppler versus PA catheter (r = 0.90, standard error of the estimate = 3.3 nun Hg); PADP by Doppler versus PA wedge pressure (r = 0.88, standard error of the estimate = 3.7 mm Hg); and CO by Doppler versus PA catheter (r = 0.92, standard error of the estimate = 0.7 L/min). Conclusion: The 2.5-MHz spherical transducer permitted accurate assessment of CO and PAD. This transducer could be of potential value in monitoring patients in the intensive care setting.
引用
收藏
页码:1381 / 1386
页数:6
相关论文
共 12 条
  • [1] DETERMINATION OF CARDIAC-OUTPUT BY TRANS-CUTANEOUS CONTINUOUS-WAVE ULTRASONIC DOPPLER COMPUTER
    CHANDRARATNA, PA
    NANNA, M
    MCKAY, C
    NIMALASURIYA, A
    SWINNEY, R
    ELKAYAM, U
    RAHIMTOOLA, SH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (01) : 234 - 237
  • [2] CHANDRARATNA PAN, 1997, Patent No. 5598845
  • [3] The effectiveness of right heart catheterization in the initial care of critically ill patients
    Connors, AF
    Speroff, T
    Dawson, NV
    Thomas, C
    Harrell, FE
    Wagner, D
    Desbiens, N
    Goldman, L
    Wu, AW
    Califf, RM
    Fulkerson, WJ
    Vidaillet, H
    Broste, S
    Bellamy, P
    Lynn, J
    Knaus, WA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11): : 889 - 897
  • [4] A COMMUNITY-WIDE ASSESSMENT OF THE USE OF PULMONARY-ARTERY CATHETERS IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION
    GORE, JM
    GOLDBERG, RJ
    SPODICK, DH
    ALPERT, JS
    DALEN, JE
    [J]. CHEST, 1987, 92 (04) : 721 - 727
  • [5] Guyatt G, 1991, J Intensive Care Med, V6, P91
  • [6] NONINVASIVE ESTIMATION OF RIGHT ATRIAL PRESSURE FROM THE INSPIRATORY COLLAPSE OF THE INFERIOR VENA-CAVA
    KIRCHER, BJ
    HIMELMAN, RB
    SCHILLER, NB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (04) : 493 - 496
  • [7] PROSPECTIVE DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF PULMONARY-ARTERY DIASTOLIC PRESSURE IN THE MEDICAL INTENSIVE-CARE UNIT
    LEE, RT
    LORD, CP
    PLAPPERT, T
    SUTTON, MS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (19) : 1366 - 1370
  • [8] CONTINUOUS-WAVE DOPPLER ECHOCARDIOGRAPHIC DETECTION OF PULMONARY REGURGITATION AND ITS APPLICATION TO NONINVASIVE ESTIMATION OF PULMONARY-ARTERY PRESSURE
    MASUYAMA, T
    KODAMA, K
    KITABATAKE, A
    SATO, H
    NANTO, S
    INOUE, M
    [J]. CIRCULATION, 1986, 74 (03) : 484 - 492
  • [9] Relation of mean right atrial pressure to echocardiographic and Doppler parameters of right atrial and right ventricular function
    Nagueh, SF
    Kopelen, HA
    Zoghbi, WA
    [J]. CIRCULATION, 1996, 93 (06) : 1160 - 1169
  • [10] NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY CONTINUOUS-WAVE DOPPLER ECHOCARDIOGRAPHY - INITIAL EXPERIENCE AND REVIEW OF THE LITERATURE
    NISHIMURA, RA
    CALLAHAN, MJ
    SCHAFF, HV
    ILSTRUP, DM
    MILLER, FA
    TAJIK, AJ
    [J]. MAYO CLINIC PROCEEDINGS, 1984, 59 (07) : 484 - 489