Determination of Femtogram-Level Plutonium Isotopes in Environmental and Forensic Samples with High-Level Uranium Using Chemical Separation and ICP-MS/MS Measurement

被引:69
作者
Hou, Xiaolin [1 ,2 ,3 ,5 ]
Zhang, Weichao [1 ,4 ]
Wang, Yanyun [1 ,4 ]
机构
[1] Chinese Acad Sci, Inst Earth Environm, State Key Lab Loess & Quaternary Geol,Xian AMS Ct, Shaanxi Key Lab Accelerator Mass Spectrometry Tec, Xian 710061, Shaanxi, Peoples R China
[2] Tech Univ Denmark, DTU Nutech, Ctr Nucl Technol, DK-4000 Roskilde, Denmark
[3] CAS Ctr Excellence Quaternary Sci & Global Change, Xian 710061, Shaanxi, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[5] Pilot Natl Lab Marine Sci & Technol Qingdao, Open Studio Ocean Continental Climate & Environm, Qingdao 266061, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
PLASMA-MASS SPECTROMETRY; ULTRA-TRACE DETERMINATION; PU ISOTOPES; REACTION CELL; GLOBAL FALLOUT; ATOM RATIOS; PU-240; SOIL; RESOLUTION; MS;
D O I
10.1021/acs.analchem.9b01347
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
ICP-MS is becoming a competitive technique for measurement of plutonium isotopes. Besides the abundance sensitivity (tailing of U-238 to m/z = 239 and 240), isobaric and polyatomic ions interferences (e.g., (UH+)-U-238-H-1) are the most critical challenges for determination of low-level plutonium in high uranium samples. This work presents a new method to solve this problem using ICP-MS with two tandem quadrupole separators and a dynamic collision/reaction cell combined with chemical separation. The interference of uranium hydrides ((UH+)-U-238-H-1 and (UH2+)-U-238-H-1) was effectively eliminated using CO2 as reaction gas by converting hydrides to oxides of uranium ions (UO+/UO2+) but still keeping the intensity of the Pu+ signal. The tailing interference of U-238(+) (abundance sensitivity) was intensively eliminated by significantly suppressing the U-238(+) signal using CO2 as reaction gas and using two tandem quadrupole mass separators in the ICP-MS/MS. With these approaches the overall interference of uranium was reduced to <1 x 10(-8), which is 3 orders of magnitude better than the conventional ICP-MS. Combined with chemical separation with a decontamination factor of 10(5) for uranium, an overall factor of 10(12) for elimination of uranium interference was achieved. The developed method was demonstrated to enable accurate determination of <10(-15) g/g level plutonium isotopes in environmental samples even in a uranium debris sample with a U/Pu atomic ratio of up to 10(12). The developed method was validated by analysis of a spiked solution and certified reference materials of soil.
引用
收藏
页码:11553 / 11561
页数:9
相关论文
共 46 条
[1]   Ultra-trace determination of 90Sr, 137Cs, 238Pu, 239Pu, and 240Pu by triple quadruple collision/reaction cell-ICP-MS/MS: Establishing a baseline for global fallout in Qatar soil and sediments [J].
Amr, Mohamed A. ;
Helal, Abdul-Fattah I. ;
Al-Kinani, Athab T. ;
Balakrishnan, Perumal .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2016, 153 :73-87
[2]   OBSERVATIONS ON PLUTONIUM IN THE OCEANS [J].
BAXTER, MS ;
FOWLER, SW ;
POVINEC, PP .
APPLIED RADIATION AND ISOTOPES, 1995, 46 (11) :1213-1223
[3]   Use of secondary ion mass spectrometry in nuclear forensic analysis for the characterization of plutonium and highly enriched uranium particles [J].
Betti, M ;
Tamborini, G ;
Koch, L .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2616-2622
[4]  
Bojanowski R., 2001, IAEA-326 and IAEA-327. Technical Report
[5]   Determination of extremely low 236U/238U isotope ratios in environmental samples by sector-field inductively coupled plasma mass spectrometry using high-efficiency sample introduction [J].
Boulyga, SF ;
Heumann, KG .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2006, 88 (01) :1-10
[6]   Isotopic analysis of uranium and plutonium using ICP-MS and estimation of burn-up of spent uranium in contaminated environmental samples [J].
Boulyga, SF ;
Becker, JS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) :1143-1147
[7]   Vertical distribution and migration of global fallout Pu in forest soils in southwestern China [J].
Bu, Wenting ;
Zheng, Jian ;
Guo, Qiuju ;
Uchida, Shigeo .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2014, 136 :174-180
[8]   Development of a high-sensitivity inductively coupled plasma mass spectrometer for actinide measurement in the femtogram range [J].
Chiappini, R ;
Taillade, JM ;
Brebion, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :497-503
[9]   The use of carbon dioxide as the reaction cell gas for the separation of uranium and plutonium in quadrupole inductively coupled plasma mass spectrometry (ICP-MS) for nuclear forensic samples [J].
Childs, Daniel A. ;
Hill, Jamie G. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (01) :139-148
[10]   HYDRIDE INTERFERENCE ON THE DETERMINATION OF MINOR ACTINIDE ISOTOPES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CRAIN, JS ;
ALVARADO, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) :1223-1227