Basic walker-assisted gait characteristics derived from forces and moments exerted on the walker's handles: Results on normal subjects

被引:37
作者
Alwan, Majd
Ledoux, Alexandre
Wasson, Glenn
Sheth, Pradip
Huang, Cunjun
机构
[1] MARC, Charlottesville, VA 22908 USA
[2] Univ Virginia, Dept Mech & Aerosp Engn, Charlottesville, VA 22903 USA
[3] Univ Virginia, Dept Comp Sci, Charlottesville, VA 22903 USA
关键词
walker-assisted gait; passive assessment of gait characteristics; detection of heel initial contact; detection of gait phases;
D O I
10.1016/j.medengphy.2006.06.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a method that passively assesses basic walker-assisted gait characteristics using only force-moment measurements from the walker's handles. The passively derived gait characteristics of 22 subjects were validated against motion capture gait analysis. The force-moment based heel initial contact detection algorithm have produced a high level of concordance with heel initial contacts detected by a human inspecting the heel marker data sets of the Vicon video capture system. The algorithm has demonstrated 97% sensitivity and 98% specificity with a narrow 95% confidence interval of +/- 1% during all experiments, which included five navigational scenarios. Temporal error in detecting the instances of heel initial contacts were within 5.27 +/- 3.66% of the overall stride time obtained from Vicon when the subjects walked in a straight line, whereas the toe-off instance estimates were within 5.18 +/- 2.75% of the gait cycle. The errors in determining the duration of stride time, single support, and double support were within 5.86 +/- 2.49%, 5.24 +/- 2.29%, and 4.34 +/- 2.13% of the gait cycle respectively. The stride time estimated, using the method presented here, correlated well with stride time computations based on visual inspection of Vicon's data, Pearson correlation coefficient r = 0.86 for straight line segments. However, absolute errors were too high to estimate the single and double support phases with acceptable accuracy. The potential application of the instrumented walker and the method presented here is longitudinal basic gait assessment that can be performed outside of the conventional gait labs. (c) 2006 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:380 / 389
页数:10
相关论文
共 20 条
  • [1] ALWAN M, 2004, P IEEE 2004 ENG MED
  • [2] Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty
    Aminian, K
    Rezakhanlou, K
    De Andres, E
    Fritsch, C
    Leyvraz, PF
    Robert, P
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (06) : 686 - 691
  • [3] Walker-assisted gait in rehabilitation: A study of biomechanics and instrumentation
    Bachschmidt, RA
    Harris, GF
    Simoneau, GG
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2001, 9 (01) : 96 - 105
  • [4] Temporal stride and force analysis of cane-assisted gait in people with hemiplegic stroke
    Chen, CL
    Chen, HC
    Wong, MK
    Tang, FT
    Chen, RS
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (01): : 43 - 48
  • [5] THE INSTRUMENTED WALKER - USAGE PATTERNS AND FORCES
    FAST, A
    WANG, FS
    ADREZIN, RS
    CORDARO, MA
    RAMIS, J
    SOSNER, J
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1995, 76 (05): : 484 - 491
  • [6] The science behind mobility devices for individuals with multiple sclerosis
    Fay, BT
    Boninger, ML
    [J]. MEDICAL ENGINEERING & PHYSICS, 2002, 24 (06) : 375 - 383
  • [7] INMAN VT, 1981, HUMAN WALKING, P26
  • [8] Using motion analysis data for foot-floor contact detection
    Karcnik, T
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (05) : 509 - 512
  • [9] The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking
    Mansfield, A
    Lyons, GM
    [J]. MEDICAL ENGINEERING & PHYSICS, 2003, 25 (10) : 879 - 885
  • [10] *MATHW INC, SIGN PROC TOOLB US G