A sensitive and rapid assay of BNP in patient blood by micro-ELISA

被引:8
作者
Mori, Emi [1 ]
Oohashi, Toshinori [2 ]
Imai, Hisashi [3 ]
Mawatari, Kazuma [1 ]
Kitamori, Takehiko [1 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
[2] Inst Microchem Technol Co Ltd, Takatsu Ku, 207 East KSP,3-2-1 Sakado, Kawasaki, Kanagawa 2130012, Japan
[3] Jichi Med Sch, Cardiovasc Med, 3311-1 Yakushiji, Shimotsuke, Tochigi 3290498, Japan
关键词
BRAIN NATRIURETIC PEPTIDE; TYPE-2; HIV-2; ANTIBODIES; MOLECULAR-FORMS; SAMPLES; STABILITY; PLASMA; SYSTEM;
D O I
10.1039/c7ay00479f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microfluidic immunoassays are expected to be the next-generation diagnosticmethods due to the small size of the reaction space and their high performance. Various tests are performed in clinics or for homemedical care. However, the analyticalmarkers are restricted in comparison to the clinical tests performed inmedical facilities. We developed a microfluidic ELISA (micro-ELISA) system, which utilized a microfluidic device for reactions and a thermal lens microscope (TLM) for detection. This system allowed a very sensitive and rapid assay due to the small size of the reaction space. In this study, to apply this systemfor clinic use, we investigated the detection of an unstable and low concentration (pg mL(-1)) marker in patient's plasma. Among the various markers, brain natriuretic peptide (BNP), a heart failure marker, was chosen because BNP is one of the difficult markers to handle in clinics and at home due to its instability (biological half-life: similar to 20 minutes); moreover, its activity in the patient's sample declines within several hours. To overcome these problems, we investigated the chemical procedure. A streptavidin-beads/biotin-antibody reaction was applied because of its high association constant, and a one-step pre-mixed method was developed for a facile process and higher sensitivity. However, commercial standard BNP with sodium azide cannot be used in this pre-mixed method because sodium azide will inhibit the activity of HRP. Therefore, the preparation and preservation stability of the standard sample was evaluated. To maintain the stability of BNP, a buffer solution containing aprotinin was used for dilution in our investigations. In addition, to reduce the influence of the viscosity changes in patient's blood samples, a dilution procedure was also considered. Based on these investigations, the quantitative analysis of BNP in only 10 mL of patient's plasma was successfully realized, whereas the conventional 96-well microtiter plate method required about 500 mL of plasma sample. Moreover, a superior performance was demonstrated in the limit of quantitation (3.61 pg mL(-1)) and short assay time (20 min for 1 sample and 70 min for 5 samples). An excellent correlation was shown between the conventional method used in the University of Tokyo Hospital and our micro-ELISA method.
引用
收藏
页码:2830 / 2834
页数:5
相关论文
共 22 条
[1]  
Guber A E, 2002, Biomed Tech (Berl), V47 Suppl 1 Pt 1, P198, DOI 10.1515/bmte.2002.47.s1a.198
[2]   N-terminal pro-Brain Natriuretic Peptide as a Predictor of Reoperation in Children With Surgically Corrected Tetralogy of Fallot [J].
Hirono, Keiichi ;
Sekine, Michikazu ;
Shiba, Noriko ;
Hayashi, Shirou ;
Nakaoka, Hideyuki ;
Ibuki, Keijiro ;
Saito, Kazuyoshi ;
Watanabe, Kazuhiro ;
Ozawa, Sayaka ;
Higuma, Tomonori ;
Yoshimura, Naoki ;
Kitajima, Isao ;
Ichida, Fukiko .
CIRCULATION JOURNAL, 2014, 78 (03) :693-700
[3]   A peptide enzyme linked immunosorbent assay (ELISA) for the detection of human immunodeficiency virus type-2 (HIV-2) antibodies: an evaluation on polymerase chain reaction (PCR) confirmed samples [J].
Kannangai, R ;
Ramalingam, S ;
Prakash, KJ ;
Abraham, OC ;
George, R ;
Castillo, RC ;
Schwartz, DH ;
Jesudason, MV ;
Sridharan, G .
JOURNAL OF CLINICAL VIROLOGY, 2001, 22 (01) :41-46
[4]   Thermal lens microscopy and microchip chemistry [J].
Kitamori, T ;
Tokeshi, M ;
Hibara, A ;
Sato, K .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :52A-60A
[5]   Enzyme Immunoassay (EIA)/Enzyme-Linked Immunosorbent Assay (ELISA) [J].
Lequin, RM .
CLINICAL CHEMISTRY, 2005, 51 (12) :2415-2418
[6]   Bead-based microfluidic immunoassays: The next generation [J].
Lim, C. T. ;
Zhang, Y. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1197-1204
[7]   Point-of-care testing (POCT): Current techniques and future perspectives [J].
Luppa, Peter B. ;
Mueller, Carolin ;
Schlichtiger, Alice ;
Schlebusch, Harald .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (06) :887-898
[8]   Comparing modified and plain peptide linked enzyme immunosorbent assay (ELISA) for detection of human immunodeficiency virus type-1 (HIV-1) and type-2 (HIV-2) antibodies [J].
Manocha, M ;
Chitralekha, KT ;
Thakar, M ;
Shashikiran, D ;
Paranjape, RS ;
Rao, DN .
IMMUNOLOGY LETTERS, 2003, 85 (03) :275-278
[9]   Analytical Method by Micro-ELISA for Small Amount of Patient Sample [J].
Mori, Emi ;
Hosoya, Yumiko ;
Imai, Yasushi ;
Oohashi, Toshinori ;
Tazawa, Hidekatsu ;
Mawatari, Kazuma ;
Morita, Hiroyuki ;
Kitamori, Takehiko .
BUNSEKI KAGAKU, 2015, 64 (06) :461-468
[10]   Disparity between studies of the stability of BNP in blood: comparison of endogenous and exogenous peptide [J].
Murdoch, DR ;
Byrne, J ;
Farmer, R ;
Morton, JJ .
HEART, 1999, 81 (02) :212-213