14N-NQR based device for detection of explosives in landmines

被引:45
作者
Ostafin, M. [1 ]
Nogaj, B. [1 ]
机构
[1] Adam Mickiewicz Univ, Dept Phys, PL-61614 Poznan, Poland
关键词
nuclear quadrupole resonance (NQR); landmine detection; explosive detection; pulsed NQR spectrometers; RDX explosive (hexogen); HMX explosive (octogen);
D O I
10.1016/j.measurement.2006.04.003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A short survey of technologies proposed and implemented so far for landmine detection is given. A laboratory prototype device intended for RDX and HMX explosive detection in landmines by means of N-14-NQR (nuclear quadrupole resonance) spectroscopy is described. This NQR based landmine detector is essentially a fully automated and computer controlled FT-NQR spectrometer equipped with a planar r.f. measure coil. The temperature dependencies of NQR frequencies v(Q)(T) in RDX and HMX in the temperature range of practical interest for explosive detection were measured. Final testing of the device has been carried out on samples of sodium nitrite (NaNO2) which had to be used to simulate real landmines in order to obey the safety regulations. Experimentally optimized SORC (strong off-resonance comb) multipulse sequence were used for optimum NQR signal. The time of detection was 30 and 90 s for sodium nitrite simulants buried in depths of 7 and 10 cm under ground, respectively. The sensitivity of detection was limited mostly by the external r.f. interferences, both man-made and naturally occurring, which enter the NQR detection system through the unshielded measure coil. Possible means to circumvent these limitations are also discussed. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:43 / 54
页数:12
相关论文
共 34 条
[1]   Pulsed spectrometer for nuclear quadrupole resonance for remote detection of nitrogen in explosives [J].
Anferov, VP ;
Mozjoukhine, GV ;
Fisher, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (04) :1656-1659
[2]  
BARRAL GA, 2000, INT M ADV NQR DET LA, P10
[3]   ZUR THEORIE DER SPIN-GITTERRELAXATION IN MOLEKULKRISTALLEN [J].
BAYER, H .
ZEITSCHRIFT FUR PHYSIK, 1951, 130 (02) :227-238
[4]  
BELYAKOV AV, 1993, INSTRUM EXP TECH+, V36, P112
[5]   Nuclear quadrupole double resonance techniques for the detection of explosives and drugs [J].
Blinc, R ;
Apih, T ;
Seliger, J .
APPLIED MAGNETIC RESONANCE, 2004, 25 (3-4) :523-534
[6]   Factors affecting the NQR line width in nitramine explosives [J].
Buess, ML ;
Caulder, SM .
APPLIED MAGNETIC RESONANCE, 2004, 25 (3-4) :383-393
[7]  
DANIELS DJ, 2000, INT M ADV NQR DET LA, P35
[8]  
GARROWAY AN, 1999, P 6 INT S AN DET EXP, pCH9
[9]  
GARROWAY AN, 1994, SPIE CARGO INSPECTIO, V2276, P142
[10]   NQR DEVICE FOR DETECTING PLASTIC EXPLOSIVES, MINES, AND DRUGS [J].
GRECHISHKIN, VS .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1992, 55 (06) :505-507