Electronic tongue for microcystin screening in waters

被引:41
作者
Lvova, L. [1 ,2 ]
Goncalves, C. Guanais [1 ]
Petropoulos, K. [1 ]
Micheli, L. [1 ]
Volpe, G. [1 ]
Kirsanov, D. [2 ,3 ]
Legin, A. [2 ,3 ]
Viaggiu, E. [4 ]
Congestri, R. [4 ]
Guzzella, L. [5 ]
Pozzoni, F. [5 ]
Palleschi, G. [1 ]
Di Natale, C. [2 ,6 ]
Paolesse, R. [1 ,2 ]
机构
[1] Univ Roma Tor Vergata, Dept Chem Sci & Technol, Rome, Italy
[2] ITMO Univ, Lab Artificial Sensory Syst, St Petersburg, Russia
[3] St Petersburg State Univ, Inst Chem, St Petersburg 199034, Russia
[4] Univ Roma Tor Vergata, Dept Biol, I-00173 Rome, Italy
[5] CNR IRSA, Brugherio, MB, Italy
[6] Univ Roma Tor Vergata, Dept Elect Engn, Rome, Italy
关键词
Cyanobacterial toxins detection; Potentiometric sensors; Multisensory analysis; Water toxicity assessment; DRINKING-WATER; CYANOBACTERIAL HEPATOTOXINS; ENVIRONMENTAL-SAMPLES; LR; TOXINS; CYANOTOXINS; AERUGINOSA; TOXICOLOGY; SENSOR; ASSAY;
D O I
10.1016/j.bios.2016.01.050
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The potentiometric E-tongue system was employed for water toxicity estimation in terms of cyanobacterial microcystin toxins (MCs) detection. The data obtained from E-tongue were correlated to the MCs content detected by the standard chromatographic technique UHPLC-DAD (Ultra High Performance Liquid Chromatography with Diode Array Detector), as far as by the colorimetric enzymatic approach. The prediction of MCs released by toxic Microcystis aeruginosa strains was possible with Root Mean Squared Error of Validation (RMSEV) lower or very close to 1 mu g/L, the provisional guideline value of WHO for MCs content in potable waters. The application of E-tongue system opens up a new perspective offset for fast and inexpensive analysis in the field of environmental monitoring, offering also the possibility to distinguish toxin producing and non-toxic M. aeruginosa strains present in potable water. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 41 条
[1]   Analysis of cyanobacterial hepatotoxins in water samples by microbore reversed-phase liquid chromatography-electrospray ionisation mass spectrometry [J].
Barco, M ;
Rivera, J ;
Caixach, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 959 (1-2) :103-111
[2]  
Bischoff H., 1963, PHYCOLOGICAL STUDIES, DOI DOI 10.1016/J.CEJ.2012.11.063
[3]   STRUCTURAL STUDIES ON CYANOGINOSIN-LR, CYANOGINOSIN-YR, CYANOGINOSIN-YA AND -CYANOGINOSIN-YM, PEPTIDE TOXINS FROM MICROCYSTIS-AERUGINOSA [J].
BOTES, DP ;
WESSELS, PL ;
KRUGER, H ;
RUNNEGAR, MTC ;
SANTIKARN, S ;
SMITH, RJ ;
BARNA, JCJ ;
WILLIAMS, DH .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 1, 1985, (12) :2747-2748
[4]   A colorimetric and fluorometric microplate assay for the detection of microcystin-LR in drinking water without preconcentration [J].
Bouaïcha, N ;
Maatouk, I ;
Vincent, G ;
Levi, Y .
FOOD AND CHEMICAL TOXICOLOGY, 2002, 40 (11) :1677-1683
[5]  
Briand E., 2012, PLOS ONE, P1
[6]   Biosensors to detect marine toxins:: Assessing seafood safety [J].
Campas, Monica ;
Prieto-Simon, Beatriz ;
Marty, Jean-Louis .
TALANTA, 2007, 72 (03) :884-895
[7]   Human fatalities from cyanobacteria: Chemical and biological evidence for cyanotoxins [J].
Carmichael, WW ;
Azevedo, SMFO ;
An, JS ;
Molica, RJR ;
Jochimsen, EM ;
Lau, S ;
Rinehart, KL ;
Shaw, GR ;
Eaglesham, GK .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2001, 109 (07) :663-668
[8]   Fabrication of a Novel and Simple Microcystin-LR Photoelectrochemical Sensor with High Sensitivity and Selectivity [J].
Chen, Kang ;
Liu, Meichuan ;
Zhao, Guohua ;
Shi, Huijie ;
Fan, Lifang ;
Zhao, Sichen .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (21) :11955-11961
[9]   The toxicology of microcystins [J].
Dawson, RM .
TOXICON, 1998, 36 (07) :953-962
[10]   Label-Free Voltammetric Aptasensor for the Sensitive Detection of Microcystin-LR Using Graphene-Modified Electrodes [J].
Eissa, Shimaa ;
Ng, Andy ;
Siaj, Mohamed ;
Zourob, Mohammed .
ANALYTICAL CHEMISTRY, 2014, 86 (15) :7551-7557