A novel Time-resolved Fluoroimmunoassay for the quantitative detection of Antibodies against the Phospholipase A2 Receptor

被引:29
|
作者
Huang, Biao [1 ]
Wang, Liang [2 ]
Zhang, Yi [1 ]
Zhang, Jue [1 ]
Zhang, Qiuhua [2 ]
Xiao, Hualong [2 ]
Zhou, Bin [1 ]
Sun, Zhuxing [2 ]
Cao, Ya-nan [3 ]
Chen, Yu [4 ]
Hu, Zhigang [2 ,4 ]
Sheng, Huiming [3 ]
机构
[1] Jiangsu Inst Nucl Med, Wuxi 214063, Peoples R China
[2] Nanjing Med Univ, Wuxi Peoples Hosp, Wuxi 214063, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Med, Tongren Hosp, Shanghai 200336, Peoples R China
[4] Zhejiang Univ, Coll Med, Affiliated Hosp 1, Hangzhou 310003, Zhejiang, Peoples R China
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
关键词
MEMBRANOUS NEPHROPATHY; AUTOANTIBODIES; ELISA; DEPOSITS;
D O I
10.1038/srep46096
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A highly sensitive time-resolved fluoroimmunoassay (TRFIA) was developed to quantify serum antibodies against the phospholipase A2 receptor (anti-PLA2R-IgG) for differential diagnosis of membranous nephropathy. Recombinant PLA2R (rPLA2R) was coated onto 96-well plates as a capture. A goat-anti-human IgG tracer was prepared with europium-chelate for detection. After bound/free separation by washing, the fluorescence counts of bound tracer were measured for quantifying serum anti-PLA2R-IgG concentration. A purified anti-PLA2R-IgG calibrator was first prepared for ensuring that consistent quantitative results could be obtained. The assay detection limit was 0.03 mg/L with linear measurement range of 0.03-340 mg/L. The intra-and inter-assay coefficients of variation (CVs) were 3.8% and 6.2%, respectively. The average serum anti-PLA2R-IgG concentration in 45 healthy volunteers, 31 IgA nephropathy, 9 lupus nephropathy, and 52 idiopathic membranous nephropathy patients was 0.53 +/- 0.18 mg/L, 0.70 +/- 0.41 mg/L, 1.08 +/- 0.65 mg/L, and 9.00 +/- 11.82 mg/L, respectively. The cut-off point for an abnormal anti-PLA2R-IgG concentration was defined as > 0.89 mg/L. The positive rates in serum from patients with IgA nephropathy, lupus nephropathy, and idiopathic membranous nephropathy were 29.0%, 44.4%, and 88.5%, respectively. The availability of this quantitation method will facilitate the use of serum anti-PLA2R-IgG for diagnosing idiopathic membranous nephropathy.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Detection of anticardiolipin antibody IgG by time-resolved fluoroimmunoassay
    Ye, Yan
    Hu, Zhigang
    Liu, Jie
    Chen, Guoqian
    Zhou, Yaohong
    Yu, Lei
    CLINICAL RHEUMATOLOGY, 2012, 31 (09) : 1339 - 1345
  • [12] A TIME-RESOLVED FLUOROIMMUNOASSAY FOR HUMAN INSULIN BASED ON 2 MONOCLONAL-ANTIBODIES
    STORCH, MJ
    MARBACH, P
    KERP, L
    JOURNAL OF IMMUNOLOGICAL METHODS, 1993, 157 (1-2) : 197 - 201
  • [13] DETECTION OF VIRAL-ANTIGENS BY TIME-RESOLVED FLUOROIMMUNOASSAY
    HALONEN, P
    MEURMAN, O
    LOVGREN, T
    HEMMILA, I
    SOINI, E
    CURRENT TOPICS IN MICROBIOLOGY AND IMMUNOLOGY, 1983, 104 : 133 - 146
  • [14] TIME-RESOLVED FLUOROIMMUNOASSAY IN THE DETECTION OF PLANT-VIRUSES
    SIITARI, H
    KURPPA, A
    JOURNAL OF GENERAL VIROLOGY, 1987, 68 : 1423 - 1428
  • [15] Detection of anticardiolipin antibody IgG by time-resolved fluoroimmunoassay
    Yan Ye
    Zhigang Hu
    Jie Liu
    Guoqian Chen
    Yaohong Zhou
    Lei Yu
    Clinical Rheumatology, 2012, 31 : 1339 - 1345
  • [16] TIME-RESOLVED FLUOROIMMUNOASSAY IN THE DETECTION OF ADENOVIRUS HEXON ANTIGEN
    MATIKAINEN, MT
    HALONEN, P
    HEMMILA, I
    LOVGREN, T
    SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1983, 18 (01) : 77 - 77
  • [17] TIME-RESOLVED FLUOROIMMUNOASSAY (TR-FIA) OF TETANUS ANTIBODIES
    HEMMILA, I
    VILJANEN, M
    LOVGREN, T
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 317 (06): : 738 - 739
  • [18] Highly sensitive time-resolved fluoroimmunoassay for the quantitative onsite detection of Alternaria longipes in tobacco
    Ji, Yuan
    Hu, Liwei
    Xiong, Wei
    Wang, Ying
    Yang, Fei
    Shi, Mowen
    Zhang, Haiyan
    Shao, Jimin
    Lu, Canhua
    Fang, Dunhuang
    Deng, Huimin
    Bian, Zhaoyang
    Tang, Gangling
    Liu, Shili
    Fan, Ziyan
    Liu, Shanshan
    JOURNAL OF APPLIED MICROBIOLOGY, 2022, 132 (02) : 1250 - 1259
  • [19] Time-resolved fluoroimmunoassay for quantitative determination of thiacloprid in agricultural samples
    Liu, Zhenjiang
    Yan, Xu
    Hua, Xiude
    Wang, Minghua
    ANALYTICAL METHODS, 2013, 5 (14) : 3572 - 3576
  • [20] Rapid simultaneous detection of verotoxin 1 and 2 using time-resolved fluoroimmunoassay
    Watanabe, K
    Arakawa, H
    Maeda, M
    BUNSEKI KAGAKU, 2002, 51 (06) : 381 - 387