Dual Signal Amplification of Glucose Oxidase-Functionalized Nanocomposites as a Trace Label for Ultrasensitive Simultaneous Multiplexed Electrochemical Detection of Tumor Markers

被引:254
作者
Lai, Guosong [1 ]
Yan, Feng [2 ]
Ju, Huangxian [1 ]
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci, Minist Educ China, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210009, Peoples R China
基金
中国国家自然科学基金;
关键词
PRUSSIAN BLUE NANOPARTICLES; IMMUNOSENSOR ARRAY; CARBON NANOTUBES; HORSERADISH-PEROXIDASE; MULTILAYER MEMBRANES; HYDROGEN-PEROXIDE; IMMUNOASSAY; PROTEINS; BIOSENSOR; DNA;
D O I
10.1021/ac901996a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel tracer, glucose oxidase-functionalized nanocomposite, was designed to label the signal antibodies for ultrasensitive multiplexed measurement of tumor markers using a disposable immunosensor array. The immunosensor array was constructed by coating layer-by-layer colloidal Prussian blue (PB), gold nanoparticles, and capture antibodies on screen-printed carbon electrodes. The preparation of glucose oxidase-functionalized nanocomposites and the labeling of antibody were performed by one-pot assembly of glucose oxidase and antibody on gold nanoparticles attached carbon nanotubes. The PB immobilized on immunosensor surface acted as a mediator to catalyze the reduction of H2O2 produced in the enzymatic cycle. Both the high-content glucose oxidase and carbon nanotubes in the tracer amplified the detectable signal for the sandwich-type immunoassay. Using carcinoembryonic antigen and (x-fetoprotein as model analytes, the simultaneous multiplexed immunoassay method using the immunosensor array and the designed tracer showed linear ranges of 3 orders of magnitude with the detection limits down to 1.4 and 2.2 pg/mL, respectively. The assay results of serum samples with the proposed method were in an acceptable agreement with the reference values. The dual signal amplification of glucose oxidase-functionalized nanocomposites provided a promising ultrasensitive simultaneous multiplexed immunoassay approach for clinical applications.
引用
收藏
页码:9730 / 9736
页数:7
相关论文
共 40 条
[1]   Double-codified gold nanolabels for enhanced immunoanalysis [J].
Ambrosi, Adriano ;
Castaneda, Maria Teresa ;
Killard, Anthony J. ;
Smyth, Malcolm R. ;
Alegret, Salvador ;
Merkoci, Arben .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5232-5240
[2]   A new antibody immobilization technique based on organic polymers protected Prussian blue nanoparticles and gold colloidal nanoparticles for amperometric immunosensors [J].
Chen, Shihong ;
Yuan, Ruo ;
Chai, Yaqin ;
Xu, Yang ;
Min, Ligen ;
Li, Na .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) :236-244
[3]   Gold nanoparticle-colloidal carbon nanosphere hybrid material: Preparation, characterization, and application for an amplified electrochemical immunoassay [J].
Cui, Rongjing ;
Liu, Chang ;
Shen, Jianming ;
Gao, Di ;
Zhu, Jun-Jie ;
Chen, Hong-Yuan .
ADVANCED FUNCTIONAL MATERIALS, 2008, 18 (15) :2197-2204
[4]   A nanocatalyst-based assay for proteins:: DNA-free ultrasensitive electrochemical detection using catalytic reduction of p-nitrophenol by gold-nanoparticle labels [J].
Das, Jagotamoy ;
Aziz, Md. Abdul ;
Yang, Haesik .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (50) :16022-16023
[5]   Carbon Nanoparticle Enhanced Immunoelectrochemical Detection for Protein Tumor Marker with Cadmium Sulfide Biotracers [J].
Ho, Ja-an Annie ;
Lin, Yeh-Chun ;
Wang, Li-Sheng ;
Hwang, Kuo-Chu ;
Chou, Pi-Tai .
ANALYTICAL CHEMISTRY, 2009, 81 (04) :1340-1346
[6]   Selective attachment of gold nanoparticles to nitrogen-doped carbon nanotubes [J].
Jiang, KY ;
Eitan, A ;
Schadler, LS ;
Ajayan, PM ;
Siegel, RW ;
Grobert, N ;
Mayne, M ;
Reyes-Reyes, M ;
Terrones, H ;
Terrones, M .
NANO LETTERS, 2003, 3 (03) :275-277
[7]   Amperometric biosensor for glutamate using Prussian Blue-based "artificial peroxldase" as a transducer for hydrogen peroxide [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1720-1723
[8]   Electrochemical enzyme immunoassay using model labels [J].
Li, Xue-Mei ;
Yang, Xiao-Yan ;
Zhang, Shu-Sheng .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (06) :543-553
[9]   Electrochemical and chemiluminescent immunosensors for tumor markers [J].
Lin, JH ;
Ju, HX .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (08) :1461-1470
[10]   A facille electrochemical method for simultaneous and on-line measurements of glucose and lactate in brain microdialysate with prussian blue as the electrocatalyst for reduction of hydrogen peroxide [J].
Lin, Yuqing ;
Liu, Kun ;
Yu, Ping ;
Xiang, Ling ;
Li, Xianchan ;
Mao, Lanqun .
ANALYTICAL CHEMISTRY, 2007, 79 (24) :9577-9583