Faecal immunochemical testing (FIT): sources of result variation based on three years of routine testing of symptomatic patients in English primary care

被引:2
|
作者
James, T. [1 ]
Nicholson, B. D. [2 ]
Marr, R. [1 ]
Paddon, M. [1 ]
East, J. E. [3 ,4 ]
Justice, S. [1 ]
Oke, J. L. [2 ]
Shine, B. [1 ]
机构
[1] Oxford Univ Hosp Trust, John Radcliffe Hosp, Dept Clin Biochem, Oxford OX3 9DU, England
[2] Univ Oxford, Nuffield Dept Primary Care Hlth Sci, Oxford, England
[3] Univ Oxford, John Radcliffe Hosp, Translat Gastroenterol Unit, Oxford, England
[4] Univ Oxford, John Radcliffe Hosp, Oxford NIHR Biomed Res Ctr, Oxford, England
关键词
Faecal immunochemical test; analytical variation; preanalytical variation; method performance;
D O I
10.1080/09674845.2021.1896204
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: We aimed to determine the analytical capabilities of a commonly used faecal immunochemical test (FIT) to detect faecal haemoglobin (Hb) in symptomatic people attending primary care in the context of the English NICE DG30 guidance. Materials and Methods: Data obtained from independent verification studies and clinical testing of the HM-JACKarc FIT method in routine primary care practice were analysed to derive performance characteristics. Results: Detection capabilities for the FIT method were 0.5 mu g/g (limit of blank), 1.3 mu g/g (limit of detection) and 3.0 mu g/g (limit of quantitation). Of 33 non-homogenized specimens, 31 (93.9%) analysed in triplicate were consistently categorized relative to 10 mu g/g, compared to all 33 (100%) homogenized specimens. Imprecision was higher (median 27.8%, (range 20.5% to 48.6%)) in non-homogenized specimens than in homogenized specimens (10.2%, (7.0 to 13.5%)). Considerable variation was observed in sequential clinical specimens from individual patients but no positive or negative trend in specimen degradation was observed over time (p = 0.26). Discussion: The FIT immunoassay evaluated is capable of detecting faecal Hb at concentrations well below the DG30 threshold of 10 mu g/g and is suitable for application in this context. The greatest practical challenge to FIT performance is reproducible sampling, the pre-analytical step associated with most variability. Further research should focus on reducing sampling variability, particularly as post-COVID-19 guidance recommends greater FIT utilization.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 50 条
  • [21] Faecal immunochemical testing for haemoglobin in detecting bowel polyps in symptomatic patients: multicentre prospective cohort study
    Bath, Michael F.
    Malhi, Aman
    Ayling, Ruth M.
    Seward, Edward
    Pritchard-Jones, Kathy
    Laszlo, Helga E.
    Hackshaw, Allan
    Machesney, Michael R.
    BJS OPEN, 2023, 7 (02):
  • [22] FAECAL IMMUNOCHEMICAL TESTING: COST EFFECTIVE WAY STRATIFYING SYMPTOMATIC PATIENTS FOR URGENT STRAIGHT TO TEST INVESTIGATION
    Singh, Baljit
    Seehra, Jaspreet
    Stephenson, James
    Barnes, Daniel
    Danaher, Paul
    Jones, James
    Osborne, Timothy
    Khasawneh, Farah
    Fernandez, Elena Perez
    Wightman-Bragg, Ellie
    GUT, 2021, 70 : A205 - A205
  • [23] Faecal immunochemical testing: cost effective way stratifying symptomatic patients for urgent straight to test investigation
    Seehra, J. K.
    Khasawneh, F.
    Singh, B.
    BRITISH JOURNAL OF SURGERY, 2021, 108 : V17 - V17
  • [24] Assessment of Knowledge of Primary Care Providers Regarding Fecal Immunochemical Testing (FIT) For Colorectal Cancer Screening
    Ona, Mel
    Papafragkakis, Charilaos
    Bashari, Daniel
    Tharayil, Zubin
    Changela, Kinesh
    Duddempudi, Sushil
    Anand, Sury
    Reddy, Madhavi
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2014, 109 : S618 - S619
  • [25] How many Colorectal cancer patients had negative Faecal Immunochemical Testing (FIT) within the previous 1 year?
    Taufik, Abdulahad
    Johnston, Dorothy
    Coulston, Rachael
    McElvanna, Kevin
    Neill, Adrian
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [26] Diagnostic accuracy for colorectal cancer of a quantitative faecal immunochemical test in symptomatic primary care patients: a study protocol
    Loov, Anna
    Hogberg, Cecilia
    Lilja, Mikael
    Theodorsson, Elvar
    Hellstrom, Per
    Metsini, Alexandra
    Olsson, Louise
    DIAGNOSTIC AND PROGNOSTIC RESEARCH, 2022, 6 (01)
  • [27] Repeat Faecal Immunochemical Testing for Colorectal Cancer Detection in Symptomatic and Screening Patients: A Systematic Review and Meta-Analysis
    Gerrard, Adam D.
    Garau, Roberta
    Xu, Wei
    Maeda, Yasuko
    Dunlop, Malcolm G.
    Theodoratou, Evropi
    Din, Farhat V. N.
    CANCERS, 2024, 16 (18)
  • [28] Faecal immunochemical testing for adults with symptoms of colorectal cancer attending English primary care: a retrospective cohort study of 14 487 consecutive test requests
    Nicholson, Brian D.
    James, Tim
    Paddon, Maria
    Justice, Steve
    Oke, Jason L.
    East, James E.
    Shine, Brian
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2020, 52 (06) : 1031 - 1041
  • [29] Systematic review and meta-analysis : diagnostic accuracy of faecal immunochemical testing for haemoglobin (FIT) in detecting colorectal cancer for both symptomatic and screening population
    Stonestreet, J.
    Chandrapalan, S.
    Woolley, D.
    Uthman, O.
    Arasaradnam, R. P.
    ACTA GASTRO-ENTEROLOGICA BELGICA, 2019, 82 (02) : 291 - 299
  • [30] Cost effectiveness of using Faecal Immunochemical Testing (FIT) as an initial diagnostic investigation for patients with lower gastrointestinal symptoms suggestive of malignancy
    CC Kearsey
    C Graham
    HS Lobb
    J Chacko
    R Weatherburn
    PS Rooney
    BMC Family Practice, 22