Determination of lead isotope ratios in seawater by quadrupole inductively coupled plasma mass spectrometry after Mg(OH)2 co-precipitation

被引:41
|
作者
Weiss, D
Boyle, EA [1 ]
Chavagnac, V
Herwegh, M
Wu, JF
机构
[1] MIT, Dept Earth Atmospher & Planetary Sci, Cambridge, MA 02139 USA
[2] Univ Bern, Inst Geol, CH-3012 Bern, Switzerland
关键词
inductively coupled plasma mass spectrometry (ICP-MS); Pb; isotope ratio; seawater; pre-concentration;
D O I
10.1016/S0584-8547(00)00176-2
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A low blank Mg(OH)(2) pre-concentration method was evaluated for the determination of lead isotope ratios (Pb-208/Pb-206, Pb-207/Pb-206) in seawater using a quadrupole ICP-MS VG Plasma Quad II +. Possible matrix effects derived from the Mg(OH), co-precipitate were assessed by spiking lead-free seawater (PbFS) and 1% (v/v) HNO3 with the certified common lead standard NBS 981 to give solutions with concentrations in the lower picogram per millilitre range. The standard curves for all three masses were linear in both matrices with minor signal loss (similar to 18%) in the Mg matrix. Mass fractionation showed similar mass biases (< 2% frac./amu) for Pb-208/Pb-206 and Pb-207/Pb-206 in both seawater and 1% (v/v) HNO3, indicating that there is no significant matrix influence on the isotope ratio determination. Using the Mg(OH)(2) precipitation method, real seawater samples were pre-concentrated approximately 28-fold, and 1 ml of 5% (v/v) HNO3 end volume was used for the subsequent measurement. The data acquisition parameters dwell time, replicates per analysis, and acquisition time were first varied to optimize analytical precision and accuracy of the ICP-MS measurements. On the basis of these results, approximately 0.5 mi of pre-concentrated solution was finally used employing a low-flow, CETAC microconcentric nebulizer to minimize sample consumption and extend acquisition time. Analyzing 18 seawater samples from the North Atlantic, the average lo external precision of triplicate measurements was approximately 0.3% for both ratios, Pb-208/Pb-206 and Pb-207/Pb-206, at the level of approximately 20 pg ml(-1) Pb. Blanks accounted for less than 3% of total lead analyzed for each sample. Six samples were also measured with TIMS and agreed in average within 0.26% for Pb-207/Pb-206 and 0.37% for Pb-208/Pb-206. Three surface water samples from the Sargasso Sea, collected in 1989, showed ratios in line with previous published ratios from the western North Atlantic. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:363 / 374
页数:12
相关论文
共 50 条
  • [21] Characterisation and correction of instrumental bias in inductively coupled plasma quadrupole mass spectrometry for accurate measurement of lead isotope ratios
    Begley, IS
    Sharp, BL
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) : 395 - 402
  • [22] Determination of cadmium, mercury and lead in seawater by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry
    Liu, HW
    Jiang, SJ
    Liu, SH
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1999, 54 (09) : 1367 - 1375
  • [23] Direct determination of lead isotope ratios by laser ablation-inductively coupled plasma-quadrupole mass spectrometry in lake sediment samples
    Aries, S
    Motelica-Heino, M
    Freydier, R
    Grezes, T
    Polvé, M
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2001, 25 (2-3): : 387 - 398
  • [24] Determination of lead isotope ratios in uranium mine products in South Africa by means of inductively coupled plasma mass spectrometry
    Manny Mathuthu
    Ntokozo Khumalo
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 315 : 1 - 12
  • [25] Determination of lead concentration and lead isotope ratios in calcium supplements by inductively coupled plasma mass spectrometry after high pressure, high temperature digestion
    Amarasiriwardena, D
    Sharma, K
    Barnes, RM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 362 (05): : 493 - 497
  • [26] Determination of lead concentration and lead isotope ratios in calcium supplements by inductively coupled plasma mass spectrometry after high pressure, high temperature digestion
    Dula Amarasiriwardena
    Kamal Sharma
    R. M. Barnes
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 493 - 497
  • [27] Determination of lead isotope ratios in uranium mine products in South Africa by means of inductively coupled plasma mass spectrometry
    Mathuthu, Manny
    Khumalo, Ntokozo
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 315 (01) : 1 - 12
  • [28] Precise determination of seawater calcium using isotope dilution inductively coupled plasma mass spectrometry
    Liu, Hou-Chun
    You, Chen-Feng
    Cai, Wei-Jun
    Chung, Chuan-Hsiung
    Huang, Kuo-Fang
    Chen, Bao-Shan
    Li, Yen
    ANALYST, 2014, 139 (04) : 734 - 741
  • [29] Direct Determination of Trace Lead in Seawater by Inductively Coupled Plasma Mass Spectrometry After Photochemical Vapor Generation
    Li, Shuzhen
    Gao, Ying
    Yu, Ying
    He, Hongyan
    Hu, Xiaorong
    Ni, Shijun
    Shi, Zeming
    Peng, Xiuhong
    Liu, Rui
    ATOMIC SPECTROSCOPY, 2017, 38 (03) : 37 - 43
  • [30] Determination of Minor Isotope Ratios in Uranium by Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Wang W.
    Xu J.
    Zhai L.-H.
    Shen X.-P.
    Yuan X.-L.
    Wei G.-Y.
    Fang S.
    Deng H.
    Li Z.-M.
    Journal of Chinese Mass Spectrometry Society, 2019, 40 (06) : 518 - 524