Heparin-coated stents

被引:0
作者
Kocsis, JF
Llanos, G
Holmer, E
机构
[1] Cordis, Warren, NJ 07059 USA
[2] Carmeda AB, SE-11347 Stockholm, Sweden
关键词
heparin; stents; subacute thrombosis; blood compatibility;
D O I
10.1615/JLongTermEffMedImplants.v10.i12.50
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stenting has revolutionized the field of interventional cardiology. However, early stud ies revealed a high incidence of thrombotic occlusion of the stent and significant bleeding complications resulting from the use of intensive anticoagulation after implantation. One of the strategies used to reduce stent thrombosis and hemorrhagic complications has been to decrease the thrombogenicity of the stent surface. For this purpose, a unique heparin surface patented by Carmeda AB (Stockholm, Sweden)-the Carmeda(R) BioActive Surface (CBAS)-has been coated onto Cordis(R) (Johnson & Johnson) stents. Preclinical evaluations of the thromboresistance of heparin-coated stents and clinical studies of heparin-coated stents in a variety of clinical settings are discussed.
引用
收藏
页码:19 / 45
页数:27
相关论文
共 108 条
[71]   ATHEROSCLEROSIS IN ANGIOGRAPHICALLY NORMAL CORONARY-ARTERY REFERENCE SEGMENTS - AN INTRAVASCULAR ULTRASOUND STUDY WITH CLINICAL CORRELATIONS [J].
MINTZ, GS ;
PAINTER, JA ;
PICHARD, AD ;
KENT, KM ;
SATLER, LF ;
POPMA, JJ ;
CHUANG, YC ;
BUCHER, TA ;
SOKOLOWICZ, LE ;
LEON, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) :1479-1485
[72]  
MIYURA Y, 1980, J BIOMED MATER RES, V14, P619
[73]   Subacute stent thrombosis and the anticoagulation controversy: Changes in drug therapy, operator technique, and the impact of intravascular ultrasound [J].
Moussa, I ;
DiMario, C ;
DiFrancesco, L ;
Reimers, B ;
Blengino, S ;
Colombo, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 :13-17
[74]   ULTRASOUND GUIDANCE OF PALMAZ-SCHATZ INTRACORONARY STENTING WITH A COMBINED INTRAVASCULAR ULTRASOUND BALLOON CATHETER [J].
MUDRA, H ;
KLAUSS, V ;
BLASINI, R ;
KROETZ, M ;
RIEBER, J ;
REGAR, E ;
THEISEN, K .
CIRCULATION, 1994, 90 (03) :1252-1261
[75]   THROMBOSIS OF A FLEXIBLE COIL CORONARY STENT - FREQUENCY, PREDICTORS AND CLINICAL OUTCOME [J].
NATH, FC ;
MULLER, DWM ;
ELLIS, SG ;
ROSENSCHEIN, U ;
CHAPEKIS, A ;
QUAIN, L ;
ZIMMERMAN, C ;
TOPOL, EJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (03) :622-627
[76]   APPLICATION OF A NEW PHASED-ARRAY ULTRASOUND IMAGING CATHETER IN THE ASSESSMENT OF VASCULAR DIMENSIONS - INVIVO COMPARISON TO CINEANGIOGRAPHY [J].
NISSEN, SE ;
GRINES, CL ;
GURLEY, JC ;
SUBLETT, K ;
HAYNIE, D ;
DIAZ, C ;
BOOTH, DC ;
DEMARIA, AN .
CIRCULATION, 1990, 81 (02) :660-666
[77]  
OLSON ST, 1993, METHOD ENZYMOL, V222, P525
[78]   INTRAVASCULAR STENTS - TISSUE-STENT INTERACTIONS AND DESIGN CONSIDERATIONS [J].
PALMAZ, JC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :613-618
[79]  
PALMAZ JC, 1993, ADV VASCULAR SURG, V1, P107
[80]  
PASCHE B, 1991, ARTIF ORGANS, V15, P481