Electroencephalogram-Based Evaluation of Impaired Sedation in Patients with Moderate to Severe COVID-19 ARDS

被引:1
作者
Flinspach, Armin Niklas [1 ]
Zinn, Sebastian [1 ]
Zacharowski, Kai [1 ]
Balaban, Uemniye [2 ]
Herrmann, Eva [2 ]
Adam, Elisabeth Hannah [1 ]
机构
[1] Goethe Univ Frankfurt, Univ Hosp Frankfurt, Dept Anaesthesiol Intens Care Med & Pain Therapy, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
[2] Goethe Univ Frankfurt, Dept Biostat & Math Modelling, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
critical care; hypnotics and sedatives; acute respiratory distress syndrome; severe acute respiratory syndrome coronavirus 2; electroencephalogram; index of consciousness-view monitor; neurophysiological monitoring; CRITICALLY-ILL PATIENTS; BISPECTRAL INDEX; STATE INDEX; VENTILATED PATIENTS; BURST SUPPRESSION; EEG; CARE; PROPOFOL; KETAMINE; RELIABILITY;
D O I
10.3390/jcm11123494
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The sedation management of patients with severe COVID-19 is challenging. Processed electroencephalography (pEEG) has already been used for sedation management before COVID-19 in critical care, but its applicability in COVID-19 has not yet been investigated. We performed this prospective observational study to evaluate whether the patient sedation index (PSI) obtained via pEEG may adequately reflect sedation in ventilated COVID-19 patients. Statistical analysis was performed by linear regression analysis with mixed effects. We included data from 49 consecutive patients. None of the patients received neuromuscular blocking agents by the time of the measurement. The mean value of the PSI was 20 (+/- 23). The suppression rate was determined to be 14% (+/- 24%). A deep sedation equivalent to the Richmond Agitation and Sedation Scale of -3 to -4 (correlation expected PSI 25-50) in bedside examination was noted in 79.4% of the recordings. Linear regression analysis revealed a significant correlation between the sedative dosages of propofol, midazolam, clonidine, and sufentanil (p < 0.01) and the sedation index. Our results showed a distinct discrepancy between the RASS and the determined PSI. However, it remains unclear to what extent any discrepancy is due to the electrophysiological effects of neuroinflammation in terms of pEEG alteration, to the misinterpretation of spinal or vegetative reflexes during bedside evaluation, or to other causes.
引用
收藏
页数:13
相关论文
共 62 条
  • [1] Electroencephalogram signatures of ketamine anesthesia-induced unconsciousness
    Akeju, Oluwaseun
    Song, Andrew H.
    Hamilos, Allison E.
    Pavone, Kara J.
    Flores, Francisco J.
    Brown, Emery N.
    Purdon, Patrick L.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2016, 127 (06) : 2414 - 2422
  • [2] Surviving Sepsis Campaign Guidelines on the Management of Adults With Coronavirus Disease 2019 (COVID-19) in the ICU: First Update
    Alhazzani, Waleed
    Evans, Laura
    Alshamsi, Fayez
    Moller, Morten Hylander
    Ostermann, Marlies
    Prescott, Hallie C.
    Arabi, Yaseen M.
    Loeb, Mark
    Gong, Michelle Ng
    Fan, Eddy
    Oczkowski, Simon
    Levy, Mitchell M.
    Derde, Lennie
    Dzierba, Amy
    Du, Bin
    Machado, Flavia
    Wunsch, Hannah
    Crowther, Mark
    Cecconi, Maurizio
    Koh, Younsuck
    Burry, Lisa
    Chertow, Daniel S.
    Szczeklik, Wojciech
    Belley-Cote, Emilie
    Greco, Massimiliano
    Bala, Malgorzata
    Zarychanski, Ryan
    Kesecioglu, Jozef
    McGeer, Allison
    Mermel, Leonard
    Mammen, Manoj J.
    Myatra, Sheila Nainan
    Arrington, Amy
    Kleinpell, Ruth
    Citerio, Giuseppe
    Lewis, Kimberley
    Bridges, Elizabeth
    Memish, Ziad A.
    Hammond, Naomi
    Hayden, Frederick G.
    Alshahrani, Muhammed
    Al Duhailib, Zainab
    Martin, Greg S.
    Kaplan, Lewis J.
    Coopersmith, Craig M.
    Antonelli, Massimo
    Rhodes, Andrew
    [J]. CRITICAL CARE MEDICINE, 2021, 49 (03) : E219 - E234
  • [3] Burst Suppression on Processed Electroencephalography as a Predictor of Postcoma Delirium in Mechanically Ventilated ICU Patients
    Andresen, Jennifer M.
    Girard, Timothy D.
    Pandharipande, Pratik P.
    Davidson, Mario A.
    Ely, E. Wesley
    Watson, Paula L.
    [J]. CRITICAL CARE MEDICINE, 2014, 42 (10) : 2244 - 2251
  • [4] Patient outcomes after hospitalisation with COVID-19 and implications for follow-up: results from a prospective UK cohort
    Arnold, David T.
    Hamilton, Fergus W.
    Milne, Alice
    Morley, Anna J.
    Viner, Jason
    Attwood, Marie
    Noel, Alan
    Gunning, Samuel
    Hatrick, Jessica
    Hamilton, Sassa
    Elvers, Karen T.
    Hyams, Catherine
    Bibby, Anna
    Moran, Ed
    Adamali, Huzaifa, I
    Dodd, James William
    Maskell, Nicholas A.
    Barratt, Shaney L.
    [J]. THORAX, 2021, 76 (04) : 399 - 401
  • [5] Effectiveness and Safety of the Awakening and Breathing Coordination, Delirium Monitoring/Management, and Early Exercise/Mobility Bundle
    Balas, Michele C.
    Vasilevskis, Eduard E.
    Olsen, Keith M.
    Schmid, Kendra K.
    Shostrom, Valerie
    Cohen, Marlene Z.
    Peitz, Gregory
    Gannon, David E.
    Sisson, Joseph
    Sullivan, James
    Stothert, Joseph C.
    Lazure, Julie
    Nuss, Suzanne L.
    Jawa, Randeep S.
    Freihaut, Frank
    Ely, E. Wesley
    Burke, William J.
    [J]. CRITICAL CARE MEDICINE, 2014, 42 (05) : 1024 - 1036
  • [6] BISPECTRAL INDEX FOR TITRATING SEDATION IN ARDS PATIENTS DURING NEUROMUSCULAR BLOCKADE
    Bass, Stephanie
    Vance, Mark L.
    Reddy, Anita
    Bauer, Seth R.
    Roach, Erin
    Torbic, Heather
    Welch, Sarah
    Duggal, Abhijit
    [J]. AMERICAN JOURNAL OF CRITICAL CARE, 2019, 28 (05) : 377 - +
  • [7] Prediction of depth of sedation and anaesthesia by the Narcotrend™ EEG monitor
    Bauerle, K
    Greim, CA
    Schroth, M
    Geisselbrecht, M
    Köbler, A
    Roewer, N
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (06) : 841 - 845
  • [8] How COVID-19 Affects the Brain
    Boldrini, Maura
    Canoll, Peter D.
    Klein, Robyn S.
    [J]. JAMA PSYCHIATRY, 2021, 78 (06) : 682 - 683
  • [9] Bispectral index (BIS) and burst suppression: Revealing a part of the BIS algorithm
    Bruhn J.
    Bouillon T.W.
    Shafer S.L.
    [J]. Journal of Clinical Monitoring and Computing, 2000, 16 (8) : 593 - 596
  • [10] Electroencephalogram approximate entropy correctly classifies the occurrence of burst suppression pattern as increasing anesthetic drug effect
    Bruhn, J
    Röpcke, H
    Rehberg, B
    Bouillon, T
    Hoeft, A
    [J]. ANESTHESIOLOGY, 2000, 93 (04) : 981 - 985