Histologic and Ultrastructural Characterization of Corneal Femtosecond Laser Trephination

被引:17
|
作者
Nuzzo, Valeria [1 ]
Aptel, Florent [1 ,2 ]
Savoldelli, Michele [2 ]
Plamann, Karsten [1 ]
Peyrot, Donald [1 ]
Deloison, Florent [1 ]
Donate, David [2 ]
Legeais, Jean-Marc [2 ]
机构
[1] ENSTA Ecole Polytech, Lab Opt Appl, CNRS, UMR 7639, F-91761 Palaiseau, France
[2] Univ Paris 05, Lab Biotechnol & Oeil, EA 4063, Paris, France
关键词
femtosecond laser; keratoplasty; microscopy; trephination; POSTERIOR LAMELLAR KERATOPLASTY; SHAPED PENETRATING KERATOPLASTY; EYE BANK EYES; REFRACTIVE SURGERY; LABORATORY MODEL; FLAP CREATION; CONFIGURATION; MICROKERATOME; MECHANISMS; STABILITY;
D O I
10.1097/ICO.0b013e318197ebeb
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to evaluate the quality of femtosecond laser corneal trephination in eye bank eyes by histologic and ultrastructural investigation. Methods: We performed Z-shaped, tophat-shaped, and mushroom-shaped trephinations of swelled corneas from eye bank eyes using an Intralase FS60 system. The corneoscleral discs were fixed immediately after the laser procedure without removing the buttons. Thin and ultrathin tissue sections were examined by light and transmission electron microscopy. Results: Optical micrographs of the corneal tissue revealed that the femtosecond laser was efficient in producing Z-shaped, tophat-shaped, and mushroom-shaped dissections with reproducible high cut regularity. Investigations by transmission electron microscopy demonstrated that cut edges were, of good quality devoid of thermal or mechanical damage of the adjacent tissues. However, cellular and collagenous nanometric debris was created by the laser. In the anterior stroma, they formed a layer of several microns in thickness residing on the terminated disrupted collagen fibers, whereas in the posterior stroma, they formed a thinner pseudomembrane running along the edges of the incision. Conclusions: Corneal trephination performed by the femtosecond laser preserves the ultrastructure of the disrupted collagen fibers. In edematous corneas, a layer of cellular and collagenic debris thicker in the anterior stroma and thinner in the posterior stroma runs along the edges of the incision obtained at a constant laser energy density.
引用
收藏
页码:908 / 913
页数:6
相关论文
共 50 条
  • [21] New approach for determining the damage level of biological tissues using femtosecond laser Advantages and application to corneal surgery
    Hoffart, L.
    Uteza, O.
    Sanner, N.
    Matonti, F.
    Sentis, M.
    Ridings, B.
    Conrath, J.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2010, 33 (09): : 610 - 616
  • [22] LASER PROCESSING AND CHARACTERIZATION WITH FEMTOSECOND LASER PULSES
    Zamfirescu, M.
    Ulmeanu, M.
    Jipa, F.
    Anghel, I.
    Simion, S.
    Dabu, R.
    Ionita, I.
    ROMANIAN REPORTS IN PHYSICS, 2010, 62 (03) : 594 - 609
  • [23] Effects of femtosecond laser-assisted trephination on donor tissue in liquid interface as compared to applanated interface
    Donner, Ruth
    Schmidinger, Gerald
    ACTA OPHTHALMOLOGICA, 2022, 100 (02) : E409 - E413
  • [24] Applications for the femtosecond laser in corneal surgery
    Slade, Stephen G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (04) : 338 - 341
  • [25] Femtosecond laser applications in corneal surgery
    Morales-Wong, Fernando
    Navas, Alejandro
    Yanez-Oviedo, Guillermo
    Mohamed-Noriega, Karim
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (03) : 293 - 305
  • [26] Current corneal femtosecond laser techniques
    Kymionis, George D.
    Karavitaki, Alexandra E.
    Portaliou, Dimitra M.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2010, 5 (02) : 143 - 146
  • [27] Tissular and mechanical effects observed with an experimental femtosecond laser microkeratome for corneal refractive surgery
    Touboul, D
    Salin, F
    Mortemousque, B
    Courjaud, A
    Chabassier, P
    Mottay, E
    Léger, F
    Colin, J
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2005, 28 (03): : 274 - 284
  • [28] Self-focusing and spherical aberrations in corneal tissue during photodisruption by femtosecond laser
    Nuzzo, Valeria
    Savoldelli, Michele
    Legeais, Jean-Marc
    Plamann, Karsten
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (03)
  • [29] Experimental corneal imaging and corneal surgery with non-amplified femtosecond laser pulses
    Huss, C.
    Krause, M.
    Loew, U.
    Riemann, I.
    Stracke, F.
    Mestres, P.
    Seitz, B.
    Koenig, K.
    OPHTHALMOLOGE, 2012, 109 (10): : 995 - 1000
  • [30] New developments in corneal refractive surgery with femtosecond laser pulses
    Le Harzic, Ronan
    Martin, Sven
    Bückle, Rainer
    Wüllner, Christian
    Donitzky, Christof
    Riemann, Iris.
    König, Karsten
    OPHTHALMIC TECHNOLOGIES XVI, 2006, 6138