Axial and Radial Force Control for a CO2 Scroll Expander

被引:17
作者
Hiwata, Akira [1 ]
Ikeda, Akira [1 ]
Morimoto, Takashi [1 ]
Kosuda, Osamu [2 ]
Matsui, Masaru [2 ]
机构
[1] Panasonic Corp, Home Appliances Co, Corp Engn Div, Appliances Dev Ctr, Shiga, Japan
[2] Panasonic Corp, Living Environm Dev Ctr, Osaka, Japan
来源
HVAC&R RESEARCH | 2009年 / 15卷 / 04期
关键词
Axial and radial forces - CO2 refrigerant - Expansion process - Oil film pressure - Operating condition - Radial forces - Scroll expander - Volumetric efficiency;
D O I
10.1080/10789669.2009.10390862
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, the scroll profile of the scroll expander was designed for CO2 refrigerant in order to make use of overexpansion and to control the axial force on the thrust bearing. This approach realized that the orbiting scroll never separated from the stationary scroll even when the operating condition changed dramatically. From the analysis on the oil-film pressure forces of the main and eccentric bearings, the radial force between the scroll wraps could be controlled, which in turn contributed to a decrease in the leakage loss in the expansion process. Test results for a prototype of the scroll expander with high-pressure shell design demonstrated the volumetric efficiency as high as 96%.
引用
收藏
页码:759 / 770
页数:12
相关论文
共 18 条
[1]  
BACK JS, 2002, P 9 INT REFR AIR CON
[2]  
FUKUTA M, 2000, P 4 IIR G LOR C NAT, P339
[3]  
Fukuta M., 2006, P 18 INT COMPR ENG C
[4]  
FUKUTA M, 2001, P INT C COMPR THEIR, P315
[5]  
Gumbel L., 1925, Reibung und Schmierung im Maschinenbau
[6]  
Heyl P, 1998, REFR SCI T, V1998, P240
[7]  
HIWATA A, 2004, P 17 INT COMPR ENG C
[8]  
Ishii N., 2002, P 16 INT COMPR ENG C
[9]  
KOHSOKABE H, 2008, P 19 INT COMPR ENG C
[10]  
Matsui M, 2008, P 19 INT COMPR ENG C