Highly stable biosensor based on glucose oxidase immobilized in chitosan film for diagnosis of diabetes

被引:0
|
作者
Zare, Hossein [1 ]
Najafpour, Ghasem D. [1 ]
Jahanshahi, Mohsen [1 ]
Rahimnejad, Mostafa [1 ]
Rezvani, Mohsen [1 ]
机构
[1] Noshirvani Univ Technol, Fac Chem Engn, Biotechnol Res Lab, Babol Sar, Iran
来源
ROMANIAN BIOTECHNOLOGICAL LETTERS | 2017年 / 22卷 / 03期
关键词
Glucose biosensor; Glucose oxidase; Chitosan; Electrochemical biosensor; Amperometry; DIRECT ELECTROCHEMISTRY; PLATINUM NANOPARTICLES; AMPEROMETRIC BIOSENSOR; CARBON NANOTUBES; ENZYME; ELECTRODE; MATRIX; FABRICATION;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this work, a highly stable electrochemical biosensor was fabricated by biomaterials for determination of glucose in the aqueous phase. Chitosan (CHIT) was used for immobilization of glucose oxidase (GOx) on the surface of platinum (Pt) electrode. The performance of the fabricated biosensor was assessed by cyclic voltammetry and amperometry. The modified electrode showed an excellent performance for glucose detection with a short response time of 5 s, high sensitivity of 38.5 mu A mM(-1) cm(-2), the linear range of 2 x 10(-4)-9.1 x 10(-3) M and detection limit of 7.4 mu M glucose at a signal to noise ratio of 3. The low value (11.3 mM) of the apparent Michaelis-Menten constant(KM) indicated that the biosensor had a high affinity to glucose. The effect of temperature on the amperometric response was investigated to evaluate the thermal stability of the biosensor. The study of the long-term stability of biosensor revealed that the modified electrode retained 97% of its initial current response after 30 days. The obtained results showed that CHIT enhanced anti-interference ability, and the thermal and long-term stability of the biosensor.
引用
收藏
页码:12611 / 12619
页数:9
相关论文
共 50 条
  • [41] An amperometric biosensor for glucose detection from glucose oxidase immobilized in polyaniline-polyvinylsulfonate-potassium ferricyanide film
    Arslan, Fatma
    Beskan, Umut
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2014, 42 (04) : 284 - 288
  • [42] Determination of glucose in human serum based on an onion primary cuticula biosensor immobilized glucose oxidase
    Jia, Wenjuan
    Liu, Wenjuan
    Zhang, Yan
    Cui, Miao
    Shuang, Shaomin
    Dong, Chuan
    Choi, Martin M. F.
    ANALYTICAL METHODS, 2012, 4 (05) : 1432 - 1437
  • [43] A highly stable oxygen-independent glucose biosensor based on a chitosan-albumin cryogel incorporated with carbon nanotubes and ferrocene
    Fatoni, Amin
    Numnuam, Apon
    Kanatharana, Proespichaya
    Limbut, Warakorn
    Thammakhet, Chongdee
    Thavarungkul, Panote
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 : 725 - 734
  • [44] A new conductometric biosensor based on horseradish peroxidase immobilized on chitosan and chitosan/gold nanoparticle films
    Valencia, German Ayala
    de Oliveira Vercik, Luci Cristina
    Vercik, Andres
    JOURNAL OF POLYMER ENGINEERING, 2014, 34 (07) : 633 - 638
  • [45] Glucose biosensor based on glucose oxidase immobilized in sol-gel chitosan/silica hybrid composite film on Prussian blue modified glass carbon electrode
    Tan, XC
    Tian, YX
    Cai, PX
    Zou, XY
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (02) : 500 - 507
  • [46] IMMOBILIZATION OF GLUCOSE OXIDASE IN SILICA SOL-GEL FILM FOR APPLICATION TO BIOSENSOR AND AMPEROMETRIC DETERMINATION OF GLUCOSE
    Demirkiran, Nizamettin
    Ekinci, Ergun
    Asilturk, Meltem
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (04) : 1336 - 1339
  • [47] An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane
    Zaide Zhou
    Lina Qiao
    Peng Zhang
    Dan Xiao
    Martin M. F. Choi
    Analytical and Bioanalytical Chemistry, 2005, 383 : 673 - 679
  • [48] Simple construction of an enzymatic glucose biosensor based on a nanocomposite film prepared in one step from iron oxide, gold nanoparticles, and chitosan
    Li, Jingjing
    Yuan, Ruo
    Chai, Yaqin
    MICROCHIMICA ACTA, 2011, 173 (3-4) : 369 - 374
  • [49] An optical glucose biosensor based on glucose oxidase immobilized on a swim bladder membrane
    Zhou, ZD
    Qiao, L
    Zhang, P
    Xiao, D
    Choi, MMF
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (04) : 673 - 679
  • [50] Glucose oxidase immobilized PANI cladding modified fiber optic intrinsic biosensor for detection of glucose
    Pahurkar, V. G.
    Tamgadge, Y. S.
    Gambhire, A. B.
    Muley, G. G.