Are occlusal splints effective in reducing myofascial pain in patients with muscle-related temporomandibular disorders? A randomized-controlled trial

被引:43
作者
Deregibus, Andrea [1 ]
Ferrillo, Martina [1 ]
Piancino, Maria Grazia [1 ]
Domini, Maria Chiara [1 ]
de Sire, Alessandro [2 ,3 ]
Castroflorio, Tommaso [1 ]
机构
[1] Univ Turin, Dent Sch, Dept Surg Sci, Turin, Italy
[2] Univ Piemonte Orientale, Dept Hlth Sci Phys & Rehabil Med, Novara, Italy
[3] Mons L Novarese Hosp, Rehabil Unit, Vercelli, Italy
关键词
Electromyography; myofascial pain syndrome; occlusal splint; pain management; rehabilitation; temporomandibular joint disorder; HUMAN MASTICATORY MUSCLES; ELECTROMYOGRAPHIC ACTIVITY; STABILIZATION SPLINT; SURFACE EMG; OROFACIAL PAIN; THERAPY; JAW; REPRODUCIBILITY; MANAGEMENT; NETWORK;
D O I
10.5606/tftrd.2021.6615
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: This study aims to evaluate the effectiveness of upper Michigan occlusal splint (OS) compared to mandibular OS in terms of pain, range of motion (ROM), and muscle activity as assessed by surface electromyography (sEMG) in patients affected by muscle-related temporomandibular disorders (TMD). Patients and methods: In this randomized-controlled trial, a total of 40 adult patients (13 males, 27 females; mean age: 47.2 +/- 12.8 years; range, 22 to 56 years) with a diagnosis of myofascial pain, lasting from at least three months on at least one masseter muscle. The patients were randomly allocated into two groups: Group 1 (n=20) using upper Michigan OS and Group 2 (n=20) using mandibular OS. At baseline (T0), at one (T1), three (T2), and six months (T3), the following outcomes were assessed: myofascial pain by Visual Analog Scale (VAS) and ROM of mandible movements, activity of the main masticatory muscles through sEMG. Results: There were no significant intra-group differences in the outcome measures assessed in both groups. However, Group 2 had a significantly higher right lateral mandibular ROM at T2 (7.1 +/- 3.1 vs. 9.8 +/- 2.3, respectively; p<0.05) and a significantly higher left lateral mandibular ROM at T3 (7.6 +/- 3.5 vs. 10.5 +/- 2.1, respectively; p<0.05). We found no significant difference in none of the sEMG parameters. Conclusion: Our study results suggest that OS, independently from being built on the upper or lower arch, seems to not have significant effects in reducing pain over a six-month period in TMD patients.
引用
收藏
页码:32 / 40
页数:9
相关论文
共 44 条
[1]   Comparison of the efficacy of dry needling and trigger point injections with exercise in temporomandibular myofascial pain treatment [J].
Aksu, Ozge ;
Dogan, Yasemin Pekin ;
Caglar, Nil Sayiner ;
Sener, Belit Merve .
TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2019, 65 (03) :228-235
[2]  
Al-Ani MZ, 2016, COCHRANE DB SYST REV, V1
[3]   Effectiveness of occlusal splint therapy in the management of temporomandibular disorders: network meta-analysis of randomized controlled trials [J].
Al-Moraissi, E. A. ;
Farea, R. ;
Qasem, K. A. ;
Al-Wadeai, M. S. ;
Al-Sabahi, M. E. ;
Al-Iryani, G. M. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (08) :1042-1056
[4]   Ultrasound evaluation of masseter muscle changes in stabilization splint treatment of myofascial type painful temporomandibular diseases [J].
Aldemir, Korkut ;
Ustuner, Evren ;
Erdem, Erdal ;
Demiralp, A. Samimi ;
Oztuna, Derya .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (03) :377-383
[5]  
Barros VD, 2009, J OROFAC PAIN, V23, P28
[6]  
Capp N J, 1986, Restorative Dent, V2, P64
[7]   Tooth surface loss - Part 3: Occlusion and splint therapy [J].
Capp, NJ .
BRITISH DENTAL JOURNAL, 1999, 186 (05) :217-222
[8]  
Capp NJ, 1986, RESTORATIVE DENT, V2, P64
[9]   Reproducibility of surface EMG variables in isometric sub-maximal contractions of jaw elevator muscles [J].
Castroflorio, T. ;
Icardi, K. ;
Becchino, B. ;
Merlo, E. ;
Debernardi, C. ;
Bracco, P. ;
Farina, D. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2006, 16 (05) :498-505
[10]   Surface EMG of jaw elevator muscles: effect of electrode location and inter-electrode distance [J].
Castroflorio, T ;
Farina, D ;
Bottin, A ;
Piancino, MG ;
Bracco, P ;
Merletti, R .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (06) :411-417