Tests results of skutterudite based thermoelectric unicouples

被引:43
作者
Saber, Hamed H.
El-Genk, Mohamed S. [1 ]
Caillat, Thierry
机构
[1] Univ New Mexico, Inst Space & Nucl Power Studies, Dept Chem & Nucl Engn, Albuquerque, NM USA
[2] CALTECH, Jet Prop Lab, Pasadena, CA USA
关键词
skutterudite; thermoelectric conversion; metallic coating; performance tests; space power;
D O I
10.1016/j.enconman.2006.06.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Tests were performed of skutterudite based unicouples with (MAY-04) and without (MAR-03) metallic coating on the legs near the hot junction to quantify the effect on reducing performance degradation with operation time. The p-legs in the unicouples were made of CeFe3.5Co0.5Sb12 and the n-legs of CoSb3. The MAY-04 test was performed in vacuum (similar to 9 X 10(-7) torr) for similar to 2000 h at hot and cold junction temperatures of 892.1 +/- 11.9 K and 316.1 +/- 5.5 K, respectively, while the MAR-03 test was performed in argon cover gas (0.051-0.068 MPa) at 972.61 +/- 10.0 K and 301.1 +/- 5.1 K, respectively. The argon cover gas decreased antimony loss from the legs in the MAR-03 test, but marked degradation in performance occurred over time. Conversely, the metallic coating in the MAY-04 test was very effective in reducing performance degradation of the unicouple. Because the cross sectional areas of the legs in MAY-04 were larger than those in MAR-03, the measured electrical power of the former is much higher than that of the latter, but the Beginning of Test (BOT) open circuit voltages, V-oc (204.2 mV) for both unicouples were almost the same. The peak electrical power of the MAY-04 unicouple decreased 12.35% from 1.62 W-e at BOT to 1.42 W-e, after similar to 2000 h of testing, while that of the MAR-03 unicouple decreased 25.37% from 0.67 to 0.5 W-e after 261 h of testing at the above temperatures. The estimated peak efficiency of the MAY-04 unicouple, shortly after BOT (10.65%), was only similar to 0.37% points lower than the theoretical value, calculated assuming zero side heat losses and zero contact resistance per leg. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:555 / 567
页数:13
相关论文
共 18 条
  • [1] BENNETT G, 1987, SPACE NUCL POWER SYS, V5, P437
  • [2] Caillat T, 2000, AIP CONF PROC, V504, P1508
  • [3] CAILLAT T, 1999, P 18 INT C THERM, P473
  • [4] CARPENTER RT, 1970, ISOTOPE RAD TECHNOLO, V9, P330
  • [5] Crowley CJ, 2005, AIP CONF PROC, V746, P601
  • [6] El-Genk MS, 2005, AIP CONF PROC, V746, P485
  • [7] Tests results and performance comparisons of coated and un-coated skutterudite based segmented unicouples
    El-Genk, MS
    Saber, HH
    Caillat, T
    Sakamoto, J
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (02) : 174 - 200
  • [8] Life tests of a skutterudites thermoelectric unicouple (MAR-03)
    El-Genk, MS
    Saber, FH
    Sakamoto, J
    Caillat, T
    [J]. TWENTY-SECOND INTERNATIONAL CONFERENCE ON THERMOELECTRICS, PROCEEDINGS ICT '03, 2003, : 417 - 420
  • [9] El-Genk MS, 2004, PROG NUCL ENERG, V44, P215, DOI 10.1016/j.pnucene.2004.01.002
  • [10] Performance analysis of coated plutonia particle fuel compact for radioisotope heater units
    El-Genk, MS
    Tournier, JM
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2001, 208 (01) : 29 - 50