Compact 24-GHz Doppler Radar Module for Non-Contact Human Vital-Sign Detection

被引:0
作者
Hsu, Tzu-Wei [1 ]
Tseng, Chao-Hsiung [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Elect & Comp Engn, Taipei, Taiwan
来源
2016 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP) | 2016年
关键词
Non-contact vital-sign sensor; 24 GHz radar; respiration and heart beat detection; Doppler radar; HEARTBEAT; BENEFITS;
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
A compact 24-GHz Doppler radar module is developed in this paper for non-contact human vital-sign detection. The 24-GHz radar transceiver chip, transmitting and receiving antennas, baseband circuits, microcontroller, and Bluetooth transmission module have been integrated and implemented on a printed circuit board. For a measurement range of 1.5 m, the developed radar module can successfully detect the respiration and heartbeat of a human adult.
引用
收藏
页码:994 / 995
页数:2
相关论文
共 8 条
  • [1] Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring
    Droitcour, AD
    Boric-Lubecke, O
    Lubecke, VM
    Lin, JS
    Kovacs, GTA
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2004, 52 (03) : 838 - 848
  • [2] Gao WH, 2007, IEEE WCNC, P2802
  • [3] Design and Analysis of a 60-GHz CMOS Doppler Micro-Radar System-in-Package for Vital-Sign and Vibration Detection
    Kao, Te-Yu J.
    Yan, Yan
    Shen, Tze-Min
    Chen, Austin Ying-Kuang
    Lin, Jenshan
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (04) : 1649 - 1659
  • [4] Experiment and spectral analysis of a low-power Ka-band heartbeat detector measuring from four sides of a human body
    Li, Changzhi
    Xiao, Yanming
    Lin, Jenshan
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2006, 54 (12) : 4464 - 4471
  • [5] Random Body Movement Cancellation in Doppler Radar Vital Sign Detection
    Li, Changzhi
    Lin, Jenshan
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (12) : 3143 - 3152
  • [6] Benefits of Coherent Low-IF for Vital Signs Monitoring Using Doppler Radar
    Mostafanezhad, Isar
    Boric-Lubecke, Olga
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2014, 62 (10) : 2481 - 2487
  • [7] A Novel Vital-Sign Sensor Based on a Self-Injection-Locked Oscillator
    Wang, Fu-Kang
    Li, Chien-Jung
    Hsiao, Chieh-Hsun
    Horng, Tzyy-Sheng
    Lin, Jenshan
    Peng, Kang-Chun
    Jau, Je-Kuan
    Li, Jian-Yu
    Chen, Cheng-Chung
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2010, 58 (12) : 4112 - 4120
  • [8] Frequency-tuning technique for remote detection of heartbeat and respiration using low-power double-sideband transmission in the Ka-band
    Xiao, Yanming
    Lin, Jenshan
    Boric-Lubecke, Olga
    Lubecke, Victor M.
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2006, 54 (05) : 2023 - 2032