Appearance of microvascular obstruction on high resolution first-pass perfusion, early and late gadolinium enhancement CMR in patients with acute myocardial infarction

被引:69
作者
Mather, Adam N. [1 ]
Lockie, Timothy [2 ,3 ]
Nagel, Eike [3 ]
Marber, Michael [2 ]
Perera, Divaka [2 ]
Redwood, Simon [2 ]
Radjenovic, Aleksandra [4 ]
Saha, Ansuman [1 ]
Greenwood, John P. [1 ]
Plein, Sven [1 ,3 ]
机构
[1] Univ Leeds, Div Cardiovasc & Neuronal Remodelling, Leeds LS2 9JT, W Yorkshire, England
[2] Kings Coll London, Rayne Inst, Div Cardiovasc, London WC2R 2LS, England
[3] Kings Coll London, Rayne Inst, Div Imaging Sci, London WC2R 2LS, England
[4] Univ Leeds, Div Med Phys, Leeds LS2 9JT, W Yorkshire, England
基金
英国惠康基金;
关键词
NO-REFLOW PHENOMENON; CARDIOVASCULAR MAGNETIC-RESONANCE; CONTRAST ENHANCEMENT; PROGNOSTIC-SIGNIFICANCE; ANGIOGRAPHIC ASSESSMENT; THROMBOLYTIC THERAPY; FUNCTIONAL RECOVERY; PRIMARY ANGIOPLASTY; TIME-COURSE; REPERFUSION;
D O I
10.1186/1532-429X-11-33
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The presence and extent of microvascular obstruction (MO) after acute myocardial infarction can be measured by first-pass gadolinium-enhanced perfusion cardiovascular magnetic resonance (CMR) or after gadolinium injection with early or late enhancement (EGE/LGE) imaging. The volume of MO measured by these three methods may differ because contrast agent diffusion into the MO reduces its apparent extent over time. Theoretically, first-pass perfusion CMR should be the most accurate method to measure MO, but this technique has been limited by lower spatial resolution than EGE and LGE as well as incomplete cardiac coverage. These limitations of perfusion CMR can be overcome using spatio-temporal undersampling methods. The purpose of this study was to compare the extent of MO by high resolution first-pass k-t SENSE accelerated perfusion, EGE and LGE. Methods: 34 patients with acute ST elevation myocardial infarction, treated successfully with primary percutaneous coronary intervention (PPCI), underwent CMR within 72 hours of admission. k-t SENSE accelerated first-pass perfusion MR (7 fold acceleration, spatial resolution 1.5 mm x 1.5 mm x 10 mm, 8 slices acquired over 2 RR intervals, 0.1 mmol/kg Gd-DTPA), EGE (14 minutes after injection with a fixed TI of 440 ms) and LGE images (1012 minutes after injection, TI determined by a Look-Locker scout) were acquired. MO volume was determined for each technique by manual planimetry and summation of discs methodology. Results: k-t SENSE first-pass perfusion detected more cases of MO than EGE and LGE (22 vs. 20 vs. 14, respectively). The extent of MO imaged by first-pass perfusion (median mass 4.7 g, IQR 6.7) was greater than by EGE (median mass 2.3 g, IQR 7.1, p = 0.002) and LGE (median mass 0.2 g, IQR 2.4, p = 0.0003). The correlation coefficient between MO mass measured by first-pass perfusion and EGE was 0.91 (p < 0.001). Conclusion: The extent of MO following acute myocardial infarction appears larger on high-resolution first-pass perfusion CMR than on EGE and LGE. Given the inevitable time delay between gadolinium administration and acquisition of either EGE or LGE images, high resolution first-pass perfusion imaging may be the most accurate method to quantify MO.
引用
收藏
页数:9
相关论文
共 29 条
  • [21] Magnitude and time course of microvascular obstruction and tissue injury after acute myocardial infarction
    Rochitte, CE
    Lima, JAC
    Bluemke, DA
    Reeder, SB
    McVeigh, ER
    Furuta, T
    Becker, LC
    Melin, JA
    [J]. CIRCULATION, 1998, 98 (10) : 1006 - 1014
  • [22] Shifting the open-artery hypothesis downstream: The quest for optimal reperfusion
    Roe, MT
    Ohman, EM
    Maas, ACP
    Christenson, RH
    Mahaffey, KW
    Granger, CB
    Harrington, RA
    Califf, RM
    Krucoff, MW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) : 9 - 18
  • [23] Early contrast-enhanced MRI predicts late functional recovery after reperfused myocardial infarction
    Rogers, WJ
    Kramer, CM
    Geskin, G
    Hu, YL
    Theobald, TM
    Vido, DA
    Petruolo, S
    Reichek, N
    [J]. CIRCULATION, 1999, 99 (06) : 744 - 750
  • [24] Detection of acutely impaired microvascular reperfusion after infarct angioplasty with magnetic resonance imaging
    Taylor, AJ
    Saadi, NA
    Al-Saadi, N
    Abdel-Aty, H
    Schulz-Menger, J
    Messroghli, DR
    Friedrich, MG
    [J]. CIRCULATION, 2004, 109 (17) : 2080 - 2085
  • [25] Recognition of the importance of embolization in atherosclerotic vascular disease
    Topol, EJ
    Yadav, JS
    [J]. CIRCULATION, 2000, 101 (05) : 570 - 580
  • [26] Angiographic assessment of myocardial reperfusion in patients treated with primary angioplasty for acute myocardial infarction - Myocardial blush grade
    van't Hof, AWJ
    Liem, A
    Suryapranata, H
    Hoorntje, JCA
    de Boer, MJ
    Zijlstra, F
    [J]. CIRCULATION, 1998, 97 (23) : 2302 - 2306
  • [27] Quantification and time course of microvascular obstruction by contrast-enhanced echocardiography and magnetic resonance imaging following acute myocardial infarction and reperfusion
    Wu, KC
    Kim, RJ
    Bluemke, DA
    Rochitte, CE
    Zerhouni, EA
    Becker, LC
    Lima, JAC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (06) : 1756 - 1764
  • [28] Prognostic significance of microvascular obstruction by magnetic resonance imaging in patients with acute myocardial infarction
    Wu, KC
    Zerhouni, EA
    Judd, RM
    Lugo-Olivieri, CH
    Barouch, LA
    Schulman, SP
    Blumenthal, RS
    Lima, JAC
    [J]. CIRCULATION, 1998, 97 (08) : 765 - 772
  • [29] Characterization of microvascular dysfunction after acute myocardial infarction by cardiovascular magnetic resonance first-pass perfusion and late gadolinium enhancement imaging
    Yan, Andrew T.
    Gibson, C. Michael
    Larose, Eric
    Anavekar, Nagesh S.
    Tsang, Sui
    Solomon, Scott D.
    Reynolds, Glenn
    Kwong, Raymond Y.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2006, 8 (06) : 831 - 837