Comparison of the Performance of the Leap Motion ControllerTM with a Standard Marker-Based Motion Capture System

被引:12
|
作者
Ganguly, Amartya [1 ]
Rashidi, Gabriel [1 ]
Mombaur, Katja [2 ]
机构
[1] Heidelberg Univ, Inst Comp Engn, Optimizat Robot & Biomech, D-69120 Heidelberg, Germany
[2] Univ Waterloo, Canada Excellence Chair Human Ctr Robot & Machine, Waterloo, ON N2L 3G1, Canada
关键词
Leap Motion Controller™ motion capture; finger kinematics; Bland– Altman analysis;
D O I
10.3390/s21051750
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Over the last few years, the Leap Motion Controller (TM) (LMC) has been increasingly used in clinical environments to track hand, wrist and forearm positions as an alternative to the gold-standard motion capture systems. Since the LMC is marker-less, portable, easy-to-use and low-cost, it is rapidly being adopted in healthcare services. This paper demonstrates the comparison of finger kinematic data between the LMC and a gold-standard marker-based motion capture system, Qualisys Track Manager (QTM). Both systems were time synchronised, and the participants performed abduction/adduction of the thumb and flexion/extension movements of all fingers. The LMC and QTM were compared in both static measuring finger segment lengths and dynamic flexion movements of all fingers. A Bland-Altman plot was used to demonstrate the performance of the LMC versus QTM with Pearson's correlation (r) to demonstrate trends in the data. Only the proximal interphalangeal joint (PIP) joint of the middle and ring finger during flexion/extension demonstrated acceptable agreement (r = 0.9062; r = 0.8978), but with a high mean bias. In conclusion, the study shows that currently, the LMC is not suitable to replace gold-standard motion capture systems in clinical settings. Further studies should be conducted to validate the performance of the LMC as it is updated and upgraded.
引用
收藏
页码:1 / 16
页数:15
相关论文
共 50 条
  • [41] Temporal-spatial reach parameters derived from inertial sensors: Comparison to 3D marker-based motion capture
    Cahill-Rowley, Katelyn
    Rose, Jessica
    JOURNAL OF BIOMECHANICS, 2017, 52 : 11 - 16
  • [42] Spatial accuracy and reliability of the Microsoft Kinect V2 in the assessment of joint movement in comparison to marker-based motion capture (Vicon)
    Otte, K.
    Kayser, B.
    Mansow-Model, S.
    Brandt, A. U.
    Verrel, J.
    Schmitz-Huebsch, T.
    MOVEMENT DISORDERS, 2016, 31 : S188 - S189
  • [43] Development of Finger Motion Reconstruction System Based on Leap Motion Controller
    Li, Xiaodong
    Wan, Kinto
    Wen, Rongwei
    Hu, Yong
    2018 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND VIRTUAL ENVIRONMENTS FOR MEASUREMENT SYSTEMS AND APPLICATIONS (CIVEMSA), 2018,
  • [44] Validation of the Leap Motion Controller using markered motion capture technology
    Smeragliuolo, Anna H.
    Hill, N. Jeremy
    Disla, Luis
    Putrino, David
    JOURNAL OF BIOMECHANICS, 2016, 49 (09) : 1742 - 1750
  • [45] Markerless motion capture estimates of lower extremity kinematics and kinetics are comparable to marker-based across 8 movements
    Song, Ke
    Hullfish, Todd J.
    Silva, Rodrigo Scattone
    Silbernagel, Karin Gravare
    Baxter, Josh R.
    JOURNAL OF BIOMECHANICS, 2023, 157
  • [46] Changes in Elbow Stress and Ball Velocity During Reduced Effort Pitching: A Marker-Based Motion Capture Analysis
    Fiegen, Anthony P.
    Nezlek, Stuart P.
    Loushin, Stacy R.
    Christoffer, Dan
    Verhoeven, Martijn
    Kaufman, Kenton R.
    Camp, Christopher L.
    Investigation Performed Mayo Clin
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2023, 51 (03): : 779 - 785
  • [47] Motion Capture based Human Motion Recognition and Imitation by Direct Marker Control
    Ott, Christian
    Lee, Dongheui
    Nakamura, Yoshihiko
    2008 8TH IEEE-RAS INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS (HUMANOIDS 2008), 2008, : 406 - 412
  • [48] Comparison of markerless and marker-based motion capture systems using 95% functional limits of agreement in a linear mixed-effects modelling framework
    Kishor Das
    Thiago de Paula Oliveira
    John Newell
    Scientific Reports, 13
  • [49] Comparison of markerless and marker-based motion capture systems using 95% functional limits of agreement in a linear mixed-effects modelling framework
    Das, Kishor
    de Paula Oliveira, Thiago
    Newell, John
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [50] A new illuminated contour-based marker system for optical motion capture
    Barca, Jan Carlo
    Rumantir, Grace
    Li, Raymond Koon
    2006 INNOVATIONS IN INFORMATION TECHNOLOGY, 2006, : 532 - +