Comparison of the Performance of the Leap Motion ControllerTM with a Standard Marker-Based Motion Capture System

被引:12
|
作者
Ganguly, Amartya [1 ]
Rashidi, Gabriel [1 ]
Mombaur, Katja [2 ]
机构
[1] Heidelberg Univ, Inst Comp Engn, Optimizat Robot & Biomech, D-69120 Heidelberg, Germany
[2] Univ Waterloo, Canada Excellence Chair Human Ctr Robot & Machine, Waterloo, ON N2L 3G1, Canada
关键词
Leap Motion Controller™ motion capture; finger kinematics; Bland– Altman analysis;
D O I
10.3390/s21051750
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Over the last few years, the Leap Motion Controller (TM) (LMC) has been increasingly used in clinical environments to track hand, wrist and forearm positions as an alternative to the gold-standard motion capture systems. Since the LMC is marker-less, portable, easy-to-use and low-cost, it is rapidly being adopted in healthcare services. This paper demonstrates the comparison of finger kinematic data between the LMC and a gold-standard marker-based motion capture system, Qualisys Track Manager (QTM). Both systems were time synchronised, and the participants performed abduction/adduction of the thumb and flexion/extension movements of all fingers. The LMC and QTM were compared in both static measuring finger segment lengths and dynamic flexion movements of all fingers. A Bland-Altman plot was used to demonstrate the performance of the LMC versus QTM with Pearson's correlation (r) to demonstrate trends in the data. Only the proximal interphalangeal joint (PIP) joint of the middle and ring finger during flexion/extension demonstrated acceptable agreement (r = 0.9062; r = 0.8978), but with a high mean bias. In conclusion, the study shows that currently, the LMC is not suitable to replace gold-standard motion capture systems in clinical settings. Further studies should be conducted to validate the performance of the LMC as it is updated and upgraded.
引用
收藏
页码:1 / 16
页数:15
相关论文
共 50 条
  • [21] Concurrent assessment of gait kinematics using marker-based and markerless motion capture
    Kanko, M. Robert
    Laende, K. Elise
    Davis, M. Elysia
    Selbie, W. Scott
    Deluzio, J. Kevin
    JOURNAL OF BIOMECHANICS, 2021, 127
  • [22] Using Marker-Based Motion Capture to Develop a Head Bobbing Robotic Lizard
    Frohnwieser, Anna
    Willmott, Alexander P.
    Murray, John C.
    Pike, Thomas W.
    Wilkinson, Anna
    From Animals to Animats 14, 2016, 9825 : 12 - 21
  • [23] Automated gap-filling for marker-based biomechanical motion capture data
    Camargo, Jonathan
    Ramanathan, Aditya
    Csomay-Shanklin, Noel
    Young, Aaron
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (15) : 1180 - 1189
  • [24] Exploring wearable sensors as an alternative to marker-based motion capture in the pitching delivery
    Boddy, Kyle J.
    Marsh, Joseph A.
    Caravan, Alex
    Lindley, Kyle E.
    Scheffey, John O.
    O'Connell, Michael E.
    PEERJ, 2019, 7
  • [25] Marker-Based Motion Capture for Measuring Joint Kinematics in Leg Swing Simulator
    Yunardi, Riky Tri
    Winarno
    2017 5TH INTERNATIONAL CONFERENCE ON INSTRUMENTATION, CONTROL, AND AUTOMATION (ICA), 2017, : 13 - 17
  • [26] A Low-Cost Marker-Based Optical Motion Capture System to Validate Inertial Measurement Units
    Siaw, Teck Ung
    Han, Yi Chiew
    Wong, Kiing Ing
    IEEE SENSORS LETTERS, 2023, 7 (02)
  • [27] Agreement between a markerless and a marker-based motion capture systems for balance related quantities
    Chaumeil, Anais
    Lahkar, Bhrigu Kumar
    Dumas, Raphael
    Muller, Antoine
    Robert, Thomas
    JOURNAL OF BIOMECHANICS, 2024, 165
  • [28] Comparison of 3D Joint Angles Measured With the Kinect 2.0 Skeletal Tracker Versus a Marker-Based Motion Capture System
    Guess, Trent M.
    Razu, Swithin
    Jahandar, Amirhossein
    Skubic, Marjorie
    Huo, Zhiyu
    JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (02) : 176 - 181
  • [29] Implementation of optical tracker system for marker-based human motion tracking
    Colahi, A.
    Hoviatalab, M.
    Rezaeian, T.
    Alizadeh, M.
    Bostan, M.
    PROCEEDINGS OF THE 15TH IASTED INTERNATIONAL CONFERENCE ON APPLIED SIMULATION AND MODELLING, 2006, : 252 - +
  • [30] Reconstruction of occluded pelvis markers during marker-based motion capture with industrial exoskeletons
    Johns, Jasper
    Bender, A.
    Glitsch, U.
    Schmidt-Bleek, L.
    Dymke, J.
    Brandl, C.
    Damm, P.
    Heinrich, K.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025, 28 (01) : 79 - 89