Stability and reproducibility of computed tomography radiomic features extracted from peritumoral regions of lung cancer lesions

被引:50
作者
Tunali, Ilke [1 ,2 ]
Hall, Lawrence O. [3 ]
Napel, Sandy [4 ]
Cherezov, Dmitry [3 ]
Guvenis, Albert [2 ]
Gillies, Robert J. [1 ]
Schabath, Matthew B. [5 ]
机构
[1] H Lee Moffitt Canc Ctr & Res Inst, Dept Canc Physiol, Tampa, FL 33612 USA
[2] Bogazici Univ, Inst Biomed Engn, TR-34684 Istanbul, Turkey
[3] Univ S Florida, Dept Comp Sci & Engn, Tampa, FL 33620 USA
[4] Stanford Univ, Sch Med, Dept Radiol, Stanford, CA 94305 USA
[5] H Lee Moffitt Canc Ctr & Res Inst, Dept Canc Epidemiol, Tampa, FL 33612 USA
关键词
CT; lung cancer; quantitative imaging; Radiomics; reproducibility; stability; CT SCANS; PULMONARY NODULES; AIDED DIAGNOSIS; SEGMENTATION; IMAGES; TUMORS; PERFORMANCE; PROGNOSIS;
D O I
10.1002/mp.13808
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Recent efforts have demonstrated that radiomic features extracted from the peritumoral region, the area surrounding the tumor parenchyma, have clinical utility in various cancer types. However, as like any radiomic features, peritumoral features could also be unstable and/or nonreproducible. Hence, the purpose of this study was to assess the stability and reproducibility of computed tomography (CT) radiomic features extracted from the peritumoral regions of lung lesions where stability was defined as the consistency of a feature by different segmentations, and reproducibility was defined as the consistency of a feature to different image acquisitions. Methods Stability was measured utilizing the "moist run" dataset and reproducibility was measured utilizing the Reference Image Database to Evaluate Therapy Response test-retest dataset. Peritumoral radiomic features were extracted from incremental distances of 3-12 mm outside the tumor segmentation. A total of 264 statistical, histogram, and texture radiomic features were assessed from the selected peritumoral region-of-interests (ROIs). All features (except wavelet texture features) were extracted using standardized algorithms defined by the Image Biomarker Standardisation Initiative. Stability and reproducibility of features were assessed using the concordance correlation coefficient. The clinical utility of stable and reproducible peritumoral features was tested in three previously published lung cancer datasets using overall survival as the endpoint. Results Features found to be stable and reproducible, regardless of the peritumoral distances, included statistical, histogram, and a subset of texture features suggesting that these features are less affected by changes (e.g., size or shape) of the peritumoral region due to different segmentations and image acquisitions. The stability and reproducibility of Laws and wavelet texture features were inconsistent across all peritumoral distances. The analyses also revealed that a subset of features were consistently stable irrespective of the initial parameters (e.g., seed point) for a given segmentation algorithm. No significant differences were found in stability for features that were extracted from ROIs bounded by a lung parenchyma mask versus ROIs that were not bounded by a lung parenchyma mask (i.e., peritumoral regions that extended outside of lung parenchyma). After testing the clinical utility of peritumoral features, stable and reproducible features were shown to be more likely to create repeatable models than unstable and nonreproducible features. Conclusions This study identified a subset of stable and reproducible CT radiomic features extracted from the peritumoral region of lung lesions. The stable and reproducible features identified in this study could be applied to a feature selection pipeline for CT radiomic analyses. According to our findings, top performing features in survival models were more likely to be stable and reproducible hence, it may be best practice to utilize them to achieve repeatable studies and reduce the chance of overfitting.
引用
收藏
页码:5075 / 5085
页数:11
相关论文
共 50 条
  • [41] Prediction Model for Tumor Budding Status Using the Radiomic Features of F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Cervical Cancer
    Chong, Gun Oh
    Park, Shin-Hyung
    Jeong, Shin Young
    Kim, Su Jeong
    Park, Nora Jee-Young
    Lee, Yoon Hee
    Lee, Sang-Woo
    Hong, Dae Gy
    Park, Ji Young
    Han, Hyung Soo
    DIAGNOSTICS, 2021, 11 (08)
  • [42] Time-distance vision transformers in lung cancer diagnosis from longitudinal computed tomography
    Li, Thomas Z.
    Xu, Kaiwen
    Gao, Riqiang
    Tang, Yucheng
    Lasko, Thomas A.
    Maldonado, Fabien
    Sandler, Kim L.
    Landman, Bennett A.
    MEDICAL IMAGING 2023, 2023, 12464
  • [43] The Prognostic Value of Radiomics Features Extracted From Computed Tomography in Patients With Localized Clear Cell Renal Cell Carcinoma After Nephrectomy
    Tang, Xin
    Pang, Tong
    Yan, Wei-feng
    Qian, Wen-lei
    Gong, You-ling
    Yang, Zhi-gang
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [44] Predictive models composed by radiomic features extracted from multi-detector computed tomography images for predicting low- and high- grade clear cell renal cell carcinoma A STARD-compliant article
    He, Xiaopeng
    Zhang, Hanmei
    Zhang, Tong
    Han, Fugang
    Song, Bin
    MEDICINE, 2019, 98 (02)
  • [45] Clinical, pathological, and computed tomography morphological features of lung cancer with spread through air spaces
    Zhang, Xiuming
    Qiao, Wei
    Shen, Jiannan
    Jiang, Qianlai
    Pan, Chunhan
    Wang, Yunnong
    Bidzinska, Joanna
    Dai, Feng
    Zhang, Lei
    TRANSLATIONAL LUNG CANCER RESEARCH, 2024, 13 (10) : 2802 - 2812
  • [46] Intratumoral and peritumoral radiomics combined with computed tomography features for predicting the invasiveness of lung adenocarcinoma presenting as a subpleural ground-glass nodule with a consolidation-to-tumor ratio ≤50%
    Wang, Yun
    Lyu, Deng
    Yu, Dan
    Hu, Su
    Ma, Yanqing
    Huang, Wenjun
    Duan, Shaofeng
    Zhou, Taohu
    Tu, Wenting
    Zhou, Xiuxiu
    Xiao, Yi
    Fan, Li
    Liu, Shiyuan
    JOURNAL OF THORACIC DISEASE, 2024, 16 (08) : 5122 - 5137
  • [47] Combination of computer extracted shape and texture features enables discrimination of granulomas from adenocarcinoma on chest computed tomography
    Orooji, Mahdi
    Alilou, Mehdi
    Rakshit, Sagar
    Beig, Niha
    Khorrami, Mohammad Hadi
    Rajiah, Prabhakar
    Thawani, Rajat
    Ginsberg, Jennifer
    Donatelli, Christopher
    Yang, Michael
    Jacono, Frank
    Gilkeson, Robert
    Velcheti, Vamsidhar
    Linden, Philip
    Madabhushi, Anant
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (02)
  • [48] Stability of radiomic features from positron emission tomography images: a phantom study comparing advanced reconstruction algorithms and ordered subset expectation maximization
    Shiiba, Takuro
    Watanabe, Masanori
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 929 - 937
  • [49] Risk of lung cancer in patients with preinvasive bronchial lesions followed by autofluorescence bronchoscopy and chest computed tomography
    Alaa RM, Mohamed
    Shibuya, Kiyoshi
    Fujiwara, Taiki
    Wada, Hironobu
    Hoshino, Hidehisa
    Yoshida, Shigetoshi
    Suzuki, Makoto
    Hiroshima, Kenzo
    Nakatani, Yukio
    Mohamed-Hussein, Aliae A. R.
    Elkholy, Maha M. S. A.
    Mahfouz, Tarek
    Yoshino, Ichiro
    LUNG CANCER, 2011, 72 (03) : 303 - 308
  • [50] Feature Ranking Importance from Multimodal Radiomic Texture Features using Machine Learning Paradigm: A Biomarker to Predict the Lung Cancer
    Shim, Seong-O
    Alkinani, Monagi H.
    Hussain, Lal
    Aziz, Wajid
    BIG DATA RESEARCH, 2022, 29