Adaptive Age Replacement Using On-Line Monitoring

被引:9
作者
Jin, Lu [1 ]
Yamamoto, Watalu [1 ]
机构
[1] Univ Electrocommun, Dept Informat, Chofugaoka 1-5-1, Chofu, Tokyo 1828585, Japan
来源
13TH GLOBAL CONGRESS ON MANUFACTURING AND MANAGEMENT | 2017年 / 174卷
关键词
Cost rate; cumulative exposure model; dynamic covariates; operating condition; time-scale; use rate; MAINTENANCE STRATEGIES; PREVENTIVE MAINTENANCE; MINIMAL-REPAIR; POLICIES; SYSTEMS; MODEL;
D O I
10.1016/j.proeng.2017.01.177
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Age replacement is one of the most used maintenance policies based on preventive action in order to prevent the failure of a system. Age replacement means that a system is replaced at failure or at a specified replacement age, whichever occurs first. In current age replacement policies, the replacement age is identified without consideration of the effects from operating conditions. However, the lifetime of a system may be affected by various operating conditions, such as the surrounding environment and the operators. In such cases, the replacement age of the system should differ for different situations. Thanks to the improvement of information communication technology, various information about the systems operating conditions can be obtained via the on-line monitoring. This research proposed an adaptive age replacement policy for systems under variable operating conditions using a cumulative exposure model. Based on the on-line information, we proposed a new time-scale instead of the age with consideration of operating conditions. Next, the new time-scale is used to determine the optimal replacement interval which will minimize the average maintenance cost per unit time (also known as cost rate). Some numerical examples are carried out in order to illustrate the proposed adaptive age replacement policy. The optimal age replacement policy considering the operating conditions reduces the total maintenance costs and enhances the effective maintenance plan for systems operating under various conditions. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 50 条
  • [41] On-line monitoring of photosynthetic activity based on pH data to assess microalgae cultivation
    Gonzalez-Camejo, J.
    Robles, A.
    Seco, A.
    Ferrer, J.
    Ruano, M. V.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2020, 276
  • [42] SIMULATION OF CATALYST ON-LINE REPLACEMENT FOR FISCHER-TROPSCH SYNTHESIS IN SLURRY BUBBLE COLUMN REACTOR
    Fan, Wei
    Hao, Xu
    Xu, Yuanyuan
    Li, Yongwang
    CHEMISTRY AND TECHNOLOGY OF FUELS AND OILS, 2011, 47 (02) : 116 - 133
  • [43] On-Line Adaptive Metabolic Flux Analysis: Application to PHB Production by Mixed Microbial Cultures
    Dias, Joao M. L.
    Pardelha, Filipa
    Eusebio, Mario
    Reis, Maria A. M.
    Oliveira, Rui
    BIOTECHNOLOGY PROGRESS, 2009, 25 (02) : 390 - 398
  • [44] On-Line Timetable Rescheduling in a Transit Line
    Ortega, Francisco A.
    Pozo, Miguel A.
    Puerto, Justo
    TRANSPORTATION SCIENCE, 2018, 52 (05) : 1106 - 1121
  • [45] Adaptive On-line State-of-available-power Prediction of Lithium-ion Batteries
    Fleischer, Christian
    Waag, Wladislaw
    Bai, Ziou
    Sauer, Dirk Uwe
    JOURNAL OF POWER ELECTRONICS, 2013, 13 (04) : 516 - 527
  • [46] A reinforcement learning based approach for on-line adaptive parameter extraction of photovoltaic array models
    Zhang, Jingwei
    Liu, Yongjie
    Li, Yuanliang
    Ding, Kun
    Feng, Li
    Chen, Xihui
    Chen, Xiang
    Wu, Jiabing
    ENERGY CONVERSION AND MANAGEMENT, 2020, 214
  • [47] In-line monitoring of electrolytes and urea during continuous renal replacement therapy
    Berger, Marc
    Sehlmeyer, Merle
    Sellering, Flora
    Roehrich, Hannes
    Perl, Thorsten
    Mansour, Hussam
    Baasner, Daniel
    Zimmermann, Stefan
    JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2020, 9 (02) : 251 - 262
  • [48] On-line passenger estimation in a metro system using particle filter
    Reyes, Francisco
    Cipriano, Aldo
    IET INTELLIGENT TRANSPORT SYSTEMS, 2014, 8 (01) : 1 - 8
  • [49] On-line block pulse implementation of a sine wave using microprocessor
    Ghosh, Suchismita
    Deb, Anish
    Sarkar, Gautam
    MEASUREMENT, 2012, 45 (06) : 1626 - 1632
  • [50] On-line Coupling of Microdialysis with Capillary Electrophoresis Using a Cross Interface
    Tuma, Petr
    Opekar, Frantisek
    Jurka, Vlastimil
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE MODERN ELECTROCHEMICAL METHODS XXXVIII, 2018, : 240 - 244