Fracture load of metal-ceramic, monolithic, and bi-layered zirconia-based posterior fixed dental prostheses after thermo-mechanical cycling

被引:40
作者
Lopez-Suarez, Carlos [1 ]
Castillo-Oyague, Raquel [1 ]
Rodriguez-Alonso, Veronica [1 ]
Lynch, Christopher D. [2 ]
Suarez-Garcia, Maria-Jesus [1 ]
机构
[1] Complutense Univ Madrid UCM, Fac Dent, Dept Conservat Dent & Buccofacial Prostheses, Pza Ramon & Cajal S-N, Madrid 28040, Spain
[2] Univ Coll Cork, Univ Dent Sch & Hosp, Cork, Ireland
关键词
Monolithic Zirconia; Veneering ceramic; CAD/CAM; Fixed dental prostheses (FDPs); Fracture load; Thermo-mechanical cycling; MARGINAL VERTICAL DISCREPANCIES; MICROTENSILE BOND STRENGTH; STABILIZED ZIRCONIA; FAILURE MODES; PREPARATION DESIGN; FLEXURAL STRENGTH; VENEERED ZIRCONIA; TOOTH-PREPARATION; PARTIAL DENTURES; RESIN CEMENTS;
D O I
10.1016/j.jdent.2018.04.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Methods: Fifty sets of two stainless-steel abutments were randomly assigned to five groups (n = 10 each) depending on the material and technique used for manufacturing the FDPs: (1) Metal-ceramic (MC, control); (2) Lava Zirconia (LZ, bi-layered); (3) Lava Plus (LM, monolithic); (4) VITA In-Ceram YZ (YZ, bi-layered); and (5) IPS e-max ZirCAD (ZZ, bi-layered). After being luted to the dies, all FDPs were submitted to thermo-mechanical cycling (120,000 masticatory cycles, 50 N; plus 774 thermal cycles of 5 degrees C/55 degrees C, dwell time: 30 s). Samples were then subjected to a three-point bending test until fracture in a universal testing machine (cross-head speed: 1 mm/min). Fracture load of the veneering ceramic (VF) and total fracture load (TF) were recorded. Microstructure and failure patterns were assessed. Data was analysed using one-way ANOVA and Tukey HSD post-hoc tests (alpha = 0.05). Results: MC restorations recorded higher VF and TF values than did zirconia FDPs (p = 0.0001), which showed no between-group differences. Within the bi-layered groups, TF was significantly higher than VF. LM pieces registered lower average grain size than did LZ specimens (p = 0.001). Overall, the connector was the weakest part. Conclusions: All of the groups tested could withstand clinical chewing forces in terms of average fracture load. Zirconia-based samples performed similarly to each other, but showed lower mean fracture load values than did metal-ceramic ones. Clinical significance: Monolithic zirconia may be recommendable for solving the chipping problem.
引用
收藏
页码:97 / 104
页数:8
相关论文
共 81 条
[21]   Fracture resistance of three porcelain-layered CAD/CAM zirconia frame designs [J].
Ferrari, Marco ;
Giovannetti, Agostino ;
Carrabba, Michele ;
Bonadeo, Giovanni ;
Rengo, Carlo ;
Monticelli, Francesca ;
Vichi, Alessandro .
DENTAL MATERIALS, 2014, 30 (07) :E163-E168
[22]   Maximal bite forces in healthy young adults as predicted by surface electromyography [J].
Ferrario, VF ;
Sforza, C ;
Zanotti, G ;
Tartaglia, GM .
JOURNAL OF DENTISTRY, 2004, 32 (06) :451-457
[23]   CERAMIC STEEL [J].
GARVIE, RC ;
HANNINK, RH ;
PASCOE, RT .
NATURE, 1975, 258 (5537) :703-704
[24]   In Vitro Fatigue and Fracture Resistance of One- and Two-Piece CAD/CAM Zirconia Implant Abutments [J].
Gehrke, Peter ;
Johannson, Dirk ;
Fischer, Carsten ;
Stawarczyk, Bogna ;
Beuer, Florian .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (03) :546-554
[25]   Effect of electric arc, gas oxygen torch and induction melting techniques on the marginal accuracy of cast base-metal and noble metal-ceramic crowns [J].
Gomez-Cogolludo, Pablo ;
Castillo-Oyaguee, Raquel ;
Lynch, Christopher D. ;
Suarez-Garcia, Maria-Jesus .
JOURNAL OF DENTISTRY, 2013, 41 (09) :826-831
[26]  
Gonzalo E, 2008, INT J PROSTHODONT, V21, P398
[27]   A COMPARISION OF THE MARGINAL VERTICAL DISCREPANCIES OF ZIRCONIUM AND METAL CERAMIC POSTERIOR FIXED DENTAL PROSTHESES BEFORE AND AFTER CEMENTATION [J].
Gonzalo, Esther ;
Suarez, Maria J. ;
Serrano, Benjamin ;
Lozano, Jose F. L. .
JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (06) :378-384
[28]  
Gonzalo E, 2009, INT J PROSTHODONT, V22, P374
[29]  
Guazzato M, 2004, INT J PROSTHODONT, V17, P142
[30]   Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling [J].
Guess, Petra C. ;
Kulis, Andreja ;
Witkowski, Siegbert ;
Wolkewitz, Martin ;
Zhang, Yu ;
Strub, Joerg R. .
DENTAL MATERIALS, 2008, 24 (11) :1556-1567