摘要
Purpose: We validated the efficacy of the vaginal sling procedure for the restoration of leak point pressure (LPP) in the rat model of stress urinary incontinence (SUI). Materials and Methods: SUI was created in 10 female Sprague-Dawley rats by bilateral pudendal nerve transection (PNT) under urethane anesthesia. Vaginal dissection was performed, followed by placement of a 2 X 0.3 cm strip of Prolene (Ethicon, Somerville, New Jersey) mesh at the mid urethral level. LPP was measured before and after PNT through a suprapubic tube using a Crede maneuver. It was also measured after vaginal dissection (sham sling) and after true sling placement. All procedures and measurements were done at the same experimental setting. In each animal LPP was measured 4 or 5 times and the mean was taken. Pairwise differences in LPP between the true and sham slings were calculated using the Wilcoxon signed rank test with p < 0.05 considered significantly different. Results: Mean LPP at baseline in all rats was 65.1 +/- 6.0 cm water. LPP decreased to 42.7 +/- 3.7 cm water after PNT. The sham sling further decreased LPP to 26.5 +/- 2.2 cm water, whereas the true sling restored LPP to 56 +/- 4.8 em water. LPP after true sling placement was not different from baseline (p = 0.16), whereas LPP after sham sling placement was significantly different from baseline (p = 0.002). Conclusions: This rat vaginal sling model represents a valid surgical method for LPP restoration in the rat model of SUI. This animal model could be used for future studies related to SUI and its treatment relevant to sling surgery.
引用
收藏
页码:2065 / 2068
页数:4
相关论文
共 50 条
  • [1] Long-term efficacy of a vaginal sling procedure in a rat model of stress urinary incontinence
    Hijaz, A
    Bena, J
    Daneshgari, F
    JOURNAL OF UROLOGY, 2005, 173 (05): : 1817 - 1819
  • [2] A new vaginal procedure for cystocele repair and treatment of stress urinary incontinence
    Benizri, EJ
    Volpe, P
    Pushkar, D
    Chevallier, D
    Amiel, J
    Sanian, H
    Toubol, J
    JOURNAL OF UROLOGY, 1996, 156 (05): : 1623 - 1625
  • [3] Epithelial inclusion cyst formation after free vaginal wall swing sling procedure for stress urinary incontinence
    Baldwin, DD
    Hadley, HR
    JOURNAL OF UROLOGY, 1997, 157 (03): : 952 - 952
  • [4] The pubofascial anchor sling procedure for recurrent genuine urinary stress incontinence
    Kane, L
    Chung, T
    Lawrie, H
    Iskaros, J
    BJU INTERNATIONAL, 1999, 83 (09) : 1010 - 1014
  • [5] SUBURETHRAL SLING VS. STANDARD COLPORRHAPHY WITH SUBURETHRAL SLING FOR STRESS URINARY INCONTINENCE ASSOCIATED WITH VAGINAL PROLAPSED
    Hajebrahimi, S.
    Haghizadeh, Y.
    Gyassi, Sadeghi F. S.
    EUROPEAN UROLOGY SUPPLEMENTS, 2010, 9 (06) : 548 - 548
  • [6] Anatomical and functional results of pubovaginal sling procedure using polypropylene mesh for the treatment of stress urinary incontinence
    Kuo, HCR
    JOURNAL OF UROLOGY, 2001, 166 (01): : 152 - 157
  • [7] Repeat Synthetic Mid Urethral Sling Procedure for Women With Recurrent Stress Urinary Incontinence
    Stav, Kobi
    Dwyer, Peter L.
    Rosamilia, Anna
    Schierlitz, Lore
    Lim, Yik N.
    Chao, Fay
    De Souza, Alison
    Thomas, Elizabeth
    Murray, Christine
    Conway, Christine
    Lee, Joseph
    JOURNAL OF UROLOGY, 2010, 183 (01): : 241 - 246
  • [8] Role of sling integrity in the restoration of leak point pressure in the rat vaginal sling model
    Hijaz, A
    Daneshgari, F
    Huang, X
    Bena, J
    Liu, GM
    Saffore, L
    Damaser, M
    JOURNAL OF UROLOGY, 2005, 174 (02): : 771 - 775
  • [9] The Safety and Efficacy of a New Adjustable Single Incision Sling for Female Stress Urinary Incontinence
    Kocjancic, Ervin
    Tu, Le-Mai
    Erickson, Ty
    Gheiler, Edward
    Van Drie, Douglas
    JOURNAL OF UROLOGY, 2014, 192 (05): : 1477 - 1482
  • [10] Assessing the Readjustable Sling Procedure (Remeex System) for Female Stress Urinary Incontinence With Detrusor Underactivity
    Ko, Kwang Jin
    Suh, Yoon Seok
    Sung, Hyun Hwan
    Ryu, Gyu Ha
    Lee, Munjae
    Lee, Kyu-Sung
    INTERNATIONAL NEUROUROLOGY JOURNAL, 2017, 21 (02) : 116 - 120