Influence of cardiac motion on diffusion-weighted magnetic resonance imaging of the liver

被引:113
作者
Kwee, Thomas C. [1 ]
Takahara, Taro [1 ]
Niwa, Tetsu [1 ,2 ]
Ivancevic, Marko K. [3 ,4 ]
Herigault, Gwenael [5 ]
Van Cauteren, Marc [6 ]
Luijten, Peter R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Kanagawa Childrens Med Ctr, Dept Radiol, Yokohama, Kanagawa, Japan
[3] Univ Michigan, Med Ctr, Dept Radiol, Ann Arbor, MI 48109 USA
[4] Philips Healthcare, Cleveland, OH USA
[5] Philips Healthcare, Best, Netherlands
[6] Philips Healthcare Asia Pacific, Tokyo, Japan
关键词
Diffusion-weighted magnetic resonance imaging; DWI; Dynamic; Liver; Cardiac motion; Pseudo-anisotropy artifact; HEPATIC PSEUDO-ANISOTROPY; MRI; SEQUENCES; ARTIFACT; FIBROSIS; LESIONS;
D O I
10.1007/s10334-009-0183-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To assess cardiac motion-induced signal loss in diffusion-weighted magnetic resonance imaging (DWI) of the liver using dynamic DWI. Three volunteers underwent dynamic coronal DWI of the liver under breathholding, in the diastolic (DWI(diast)) or systolic (DWI(syst)) cardiac phase, and with motion probing gradients (MPGs) in phase encoding (P, left-right), frequency encoding (M, superior-inferior), or slice select (S, anterior-posterior) direction. Liver-to-background contrasts (LBCs) of DWI(syst) were compared to those of DWI(diast), for both the left and right liver lobes, using nonparametric tests. Signal decrease ratios (SDRs) were calculated as (1-(LBCDWI(syst)/LBCDWI(diast))) x 100%. DWI(syst) was further analyzed to determine which direction of MPGs was most affected by cardiac motion. In the left liver lobe, LBCs of DWI(syst) (median 3.35) were significantly lower (P < 0.0001) than those of DWI(diast) (median 4.84). In the right liver lobe, LBCs of DWI(syst) (median 4.17) were also significantly lower (P < 0.0001) than those of DWI(diast) (median 5.35 ). SDRs of the left and right liver lobes were 25.5% and 17.3%, respectively. In DWI(syst), the significantly lowest (P < 0.05) LBCs were observed in the M direction (left liver lobe) and P direction (right liver lobe) of MPGs. Signal intensity of both liver lobes are affected by cardiac motion in DWI. In the left liver lobe, signal loss especially occurs in the superior-inferior direction of MPGs, whereas in the right lobe, signal loss especially occurs in the left-right direction of MPGs.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 15 条
[1]  
Conover William Jay, 1999, Practical nonparametric statistics, V350
[2]   PULSATILE BRAIN MOVEMENT AND ASSOCIATED HYDRODYNAMICS STUDIED BY MAGNETIC-RESONANCE PHASE IMAGING - THE MONRO-KELLIE DOCTRINE REVISITED [J].
GREITZ, D ;
WIRESTAM, R ;
FRANCK, A ;
NORDELL, B ;
THOMSEN, C ;
STAHLBERG, F .
NEURORADIOLOGY, 1992, 34 (05) :370-380
[3]   Respiratory-Triggered Versus Breath-Hold Diffusion-Weighted MRI of Liver Lesions: Comparison of Image Quality and Apparent Diffusion Coefficient Values [J].
Kandpal, Harsh ;
Sharma, Raju ;
Madhusudhan, K. S. ;
Kapoor, Kulwant Singh .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :915-922
[4]   Apparent diffusion coefficient measurements with diffusion-weighted magnetic resonance imaging for evaluation of hepatic fibrosis [J].
Koinuma, M ;
Ohashi, I ;
Hanafusa, K ;
Shibuya, H .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (01) :80-85
[5]   Comparison and Reproducibility of ADC Measurements in Breathhold, Respiratory Triggered, and Free-Breathing Diffusion-Weighted MR Imaging of the Liver [J].
Kwee, Thomas C. ;
Takahara, Taro ;
Koh, Dow-Mu ;
Nievelstein, Rutger A. J. ;
Luijten, Peter R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (05) :1141-1148
[6]   Abdominal MRI advances in the detection of liver tumours and characterisation [J].
Low, Russell N. .
LANCET ONCOLOGY, 2007, 8 (06) :525-535
[7]   Abdomen:: Diffusion-weighted MR imaging with pulse-triggered single-shot sequences [J].
Mürtz, P ;
Flacke, S ;
Träber, F ;
van den Brink, JS ;
Gieseke, J ;
Schild, HH .
RADIOLOGY, 2002, 224 (01) :258-264
[8]  
Naganawa Shinji, 2005, Magn Reson Med Sci, V4, P175, DOI 10.2463/mrms.4.175
[9]   Hepatic pseudo-anisotropy: a specific artifact in hepatic diffusion-weighted images obtained with respiratory triggering [J].
Nasu, Katsuhiro ;
Kuroki, Yoshifumi ;
Fujii, Hirofumi ;
Minami, Manabu .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2007, 20 (04) :205-211
[10]   Measurement of the apparent diffusion coefficient in the liver: Is it a reliable index for hepatic disease diagnosis? [J].
Nasu K. ;
Kuroki Y. ;
Sekiguchi R. ;
Kazama T. ;
Nakajima H. .
Radiation Medicine, 2006, 24 (6) :438-444