Gold-functionalized stainless-steel wire and tube for fiber-in-tube solid-phase microextraction coupled to high-performance liquid chromatography for the determination of polycyclic aromatic hydrocarbons

被引:14
作者
Bu, Yanan [1 ]
Feng, Juanjuan [1 ]
Sun, Min [1 ]
Zhou, Changli [1 ]
Luo, Chuannan [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Key Lab Chem Sensing & Anal Univ Shandong, Jinan 250022, Peoples R China
基金
中国国家自然科学基金;
关键词
Fiber-in-tube; Gold; Polycyclic aromatic hydrocarbons; Solid-phase microextraction; Stainless steel; SENSITIVE ANALYSIS; CAPILLARY; SAMPLES; COLUMN;
D O I
10.1002/jssc.201501103
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fiber-in-tube solid-phase microextraction device based on a gold-functionalized stainlesssteel wire and tube was developed and characterized by scanning electron microscopy and energy dispersive X-ray spectroscopy. In combination with high-performance liquid chromatography, it was evaluated using six polycyclic aromatic hydrocarbons as model analytes. Important parameters including sampling rate, sample volume, organic solvent content and desorption time were investigated. Under optimized conditions, an online analysis method was established. The linearity was in the range of 0.15-50 mu g/L with correlation coefficients ranging from 0.9989 to 0.9999, and limits of detection ranged from 0.05 to 0.1 mu g/L. The method was applied to determine model analytes in mosquito-repellent incense ash and river water samples, with recoveries in the range of 85-120%.
引用
收藏
页码:932 / 938
页数:7
相关论文
共 32 条
  • [1] An unbreakable on-line approach towards sol-gel capillary microextraction
    Bagheri, Habib
    Piri-Moghadam, Hamed
    Es'haghi, Ali
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (26) : 3952 - 3957
  • [2] New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aromatic hydrocarbons in bivalves
    Campins-Falco, P.
    Verdu-Andres, J.
    Sevillano-Cabeza, A.
    Molins-Legua, C.
    Herraez-Hernandez, R.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1211 (1-2) : 13 - 21
  • [3] In-tube solid-phase microextraction coupled by in valve mode to capillary LC-DAD: Improving detectability to multiresidue organic pollutants analysis in several whole waters
    Campins-Falco, P.
    Verdu-Andres, J.
    Sevillano-Cabeza, A.
    Herraez-Hernandez, R.
    Molins-Legua, C.
    Moliner-Martinez, Y.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (16) : 2695 - 2702
  • [4] Sample preparation
    Chen, Yi
    Guo, Zhenpeng
    Wang, Xiaoyu
    Qiu, Changgui
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) : 191 - 219
  • [5] Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography
    Eisert, R
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (16) : 3140 - 3147
  • [6] Nanostructured copper-coated solid-phase microextraction fiber for gas chromatographic analysis of dibutyl phthalate and diethylhexyl phthalate environmental estrogens
    Feng, Juanjuan
    Sun, Min
    Bu, Yanan
    Luo, Chuannan
    [J]. JOURNAL OF SEPARATION SCIENCE, 2015, 38 (01) : 128 - 133
  • [7] A novel silver-coated solid-phase microextraction metal fiber based on electroless plating technique
    Feng, Juanjuan
    Sun, Min
    Li, Jubai
    Liu, Xia
    Jiang, Shengxiang
    [J]. ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 174 - 180
  • [8] Au nanoparticles as a novel coating for solid-phase microextraction
    Feng, Juanjuan
    Sun, Min
    Liu, Hongmei
    Li, Jubai
    Liu, Xia
    Jiang, Shengxiang
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (52) : 8079 - 8086
  • [9] Goclaves C., 2002, J CHROMATOGR A, V968, P177
  • [10] Automated in-tube solid-phase microextraction-high-performance liquid chromatography for carbamate pesticide analysis
    Gou, YN
    Eisert, R
    Pawliszyn, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (01) : 137 - 147