A comparison of two nickel-titanium instrumentation techniques in teeth using microcomputed tomography

被引:38
作者
Rhodes, JS
Ford, TRP
Lynch, JA
Curtis, RV
机构
[1] Guys Hosp, Kings Coll, GTK Dent Inst, Dept Radiol Sci, London SE1 9RT, England
[2] Guys Hosp, Kings Coll, GTK Dent Inst, Dept Mat Sci, London SE1 9RT, England
关键词
microcomputed tomography; nickel-titanium root canal preparation; three-dimensional imaging;
D O I
10.1046/j.1365-2591.1999.00306.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim The aim of the study was to compare the shaping of root canals by two nice-titanium instrumentation techniques using microcomputed tomography (MCT). Methodology Ten mandibular first molar teeth (30 canals) that had intact crowns and fully formed roots were scanned using MCT. Fifteen canals were instrumented using NiTiFlex hand files (Maillefer) using balanced force. The remainder were instrumented using prototype Profile 0.04 Taper instruments (Dentsply) in a crown-down manner to an apical size ISO 25. The teeth were scanned again following instrumentation. The two instrumentation techniques were compared in a total of 27 canals. The area of dentine removed at predetermined levels (2.0, 3.0, 4.5, 6,0, 7.5 mm) from the apex was measured. Transportation and centring were recorded. Images constructed at these levels were compared with video images of equivalent physical sections created after the second scan, The volume of dentine removed in the apical 7.5 mm of the root canals of each tooth was calculated and the different techniques compared. Rendered three-dimensional images were used to assess the preparations qualitatively. The time taken for preparation was recorded. Results There was no significant difference between hand instrumentation with NitiFlex files and machine instrumentation with prototype Profile 0.04 Taper instruments for any of the variables tested. Conclusions Both techniques produced well centred and tapered preparations.
引用
收藏
页码:279 / 285
页数:7
相关论文
共 19 条
  • [1] [Anonymous], 1921, J NATL DENT ASS
  • [2] A comparison of stainless steel Flexofiles and nickel-titanium NiTiFlex files during the shaping of simulated canals
    Bishop, K
    Dummer, PMH
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1997, 30 (01) : 25 - 34
  • [3] A COMPARISON OF CANAL PREPARATION WITH NICKEL-TITANIUM AND STAINLESS-STEEL INSTRUMENTS
    ESPOSITO, PT
    CUNNINGHAM, CJ
    [J]. JOURNAL OF ENDODONTICS, 1995, 21 (04) : 173 - 176
  • [4] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [5] Comparison of nickel-titanium and stainless steel hand-file instrumentation using computed tomography
    Gambill, JM
    Alder, M
    delRio, CE
    [J]. JOURNAL OF ENDODONTICS, 1996, 22 (07) : 369 - 375
  • [6] JARDINE SJ, 1998, INT ENDOD J, V31, P199
  • [7] KERSH M, 1995, J ENDODONT, V19, P193
  • [8] THE VALIDITY OF SIMULATED ROOT CANALS FOR THE INVESTIGATION OF THE PREPARED ROOT-CANAL SHAPE
    LIM, KC
    WEBBER, J
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1985, 18 (04) : 240 - 246
  • [9] MICROCOMPUTED TOMOGRAPHY - AN ADVANCED SYSTEM FOR DETAILED ENDODONTIC RESEARCH
    NIELSEN, RB
    ALYASSIN, AM
    PETERS, DD
    CARNES, DL
    LANCASTER, J
    [J]. JOURNAL OF ENDODONTICS, 1995, 21 (11) : 561 - 568
  • [10] Micro-computed tomography: a new tool for experimental endodontology
    Rhodes, JS
    Ford, TRP
    Lynch, JA
    Liepins, PJ
    Curtis, RV
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (03) : 165 - 170