Development of a novel larynx pacemaker multichannel array electrode: In vivo animal analysis

被引:5
作者
Faenger, Bernd [1 ]
Schumann, Nikolaus P. [1 ]
Arnold, Dirk [1 ,2 ]
Grassme, Roland [1 ,4 ]
Guntinas-Lichius, Orlando [3 ]
Scholle, Hans-Christoph [1 ]
机构
[1] Jena Univ Hosp, Dept Trauma Hand & Reconstruct Surg, Div Motor Res Pathophysiol & Biomech, Jena, Germany
[2] Univ Jena, Inst Systemat Zool & Evolutionary Biol Phylet Mus, D-07740 Jena, Germany
[3] Jena Univ Hosp, Dept Otorhinolaryngol, Jena, Germany
[4] Geschaftsbereich Pravent, Berufsgenossenschaft Nahrungsmittel & Gastgewerbs, Aussenstelle Erfurt, Germany
关键词
Larynx pacemaker; multichannel array electrode; EMG; electromyography; material evaluation; VOCAL CORD PARALYSIS; ELECTRICAL-STIMULATION; THYROPLASTY; MUSCLES; ARYTENOIDECTOMY; MEDIALIZATION; EXPERIENCE; RESTORES; CANINE;
D O I
10.1002/lary.25512
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/HypothesisElectrical stimulation of posterior cricoarytenoid muscle offers a physiological approach to retain the function of the paralyzed larynx muscle after paralysis. The aim of this study was to develop and evaluate a durable, biocompatible, and atraumatic array electrode for inclusion in a larynx pacemaker. In addition to developing the electrode array, an evaluation methodology using in vivo multichannel electromyography was assessed. Study DesignIn vivo test procedures for material evaluation: an animal model. MethodsOver the research period, 42 array electrodes representing nine different prototypes were implanted in the triceps brachii muscle of 21 rats. Biocompatibility and atraumatic functions were evaluated via observation. Electrode function and durability were determined by comparison of daily electromyographic measurements of the muscle activity of the front leg (triceps brachii muscle) during locomotion. ResultsThe used animal model demonstrated electrode material problems that could not be material evaluation from in vitro tests alone. Through use of this in vivo method, it was found that an array tip that is durable, biocompatible, and atraumatic should consist of many small electrode plates cast in flexible silicone. The connecting wires to the individual electrode plates should be Litz wire, which consists of multiple strands. ConclusionsThe here demonstrated in vivo test method was a suitable animal model for designing and evaluating electrodes to be further developed for inclusion in human implants. Level of EvidenceN/A. Laryngoscope, 126:429-436, 2016
引用
收藏
页码:429 / 436
页数:8
相关论文
共 24 条
[1]  
BERGMANN K, 1988, LARYNGOSCOPE, V98, P455
[2]   Surface EMC-recordings using a miniaturised matrix electrode: a new technique for small animals [J].
Biedermann, F ;
Schumann, NP ;
Fischer, MS ;
Scholle, HC .
JOURNAL OF NEUROSCIENCE METHODS, 2000, 97 (01) :69-75
[3]  
BRONIATOWSKI M, 1985, LARYNGOSCOPE, V95, P1194
[4]   CARBON-DIOXIDE LASER POSTERIOR CORDECTOMY FOR TREATMENT OF BILATERAL VOCAL CORD PARALYSIS [J].
DENNIS, DP ;
KASHIMA, H .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1989, 98 (12) :930-934
[5]   External vocal fold medialization (thyroplasty type I): Surgical experience and modifications [J].
Friedrich, G .
LARYNGO-RHINO-OTOLOGIE, 1998, 77 (01) :7-17
[6]   Criteria for the selection of materials for implanted electrodes [J].
Geddes, LA ;
Roeder, R .
ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (07) :879-890
[7]   Measurement of the direct-current (Faradic) resistance of the electrode-electrolyte interface for commonly used electrode materials [J].
Geddes, LA ;
Roeder, R .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (02) :181-186
[8]  
Grill WM, 1994, ANN BIOMED ENG, V22, P22
[9]   THYROPLASTY AS A NEW PHONOSURGICAL TECHNIQUE [J].
ISSHIKI, N ;
MORITA, H ;
OKAMURA, H ;
HIRAMOTO, M .
ACTA OTO-LARYNGOLOGICA, 1974, 78 (5-6) :451-457
[10]  
KLEINSASSER O, 1982, HNO, V30, P275