Orthogonal array design experiments for optimizing the separation of nine pesticides by micellar electrokinetic chromatography

被引:17
|
作者
Zhang, YP [1 ]
Li, XJ [1 ]
Yuan, ZB [1 ]
Lu, YQ [1 ]
机构
[1] Univ Sci & Technol China, Acad Sinica, Grad Sch, Dept Chem, Beijing 100039, Peoples R China
基金
中国国家自然科学基金;
关键词
orthogonal arrany design; optimization; pesticides;
D O I
10.1016/S0026-265X(02)00096-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Separation in micellar electrokinetic chromatography is influenced by many factors. The separation of 9 pesticides was optimized using orthogonal array designs (OADs), five relevant factors were investigated: type and concentration of surfactant, concentration of buffer, pH and concentration of urea modifier. In the first experiment, five factors were examined at two levels using an OA(16)(2(15)) matrix, by which the effect of each factor was estimated using individual contributions as response function, based on the results of the first experiment, three more important factors were chosen for further optimization using OA(9) (3(4)) matrix to locate the exact levels for each variable. Finally, 9 pesticides achieved baseline-separation within 15 min. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:307 / 315
页数:9
相关论文
共 50 条
  • [1] Orthogonal array design experiments for optimizing the separation of various pesticides by cyclodextrin-modified micellar electrokinetic chromatography
    He, Y
    Lee, HK
    JOURNAL OF CHROMATOGRAPHY A, 1998, 793 (02) : 331 - 340
  • [2] Optimizing separation conditions for polycyclic aromatic hydrocarbons in micellar electrokinetic chromatography
    Hsieh, MM
    Kuo, YC
    Tsai, PL
    Chang, HT
    JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) : 397 - 405
  • [3] Enantiomeric and isomeric separation of pesticides by cyclodextrin-modified micellar electrokinetic chromatography
    Shea, D
    Penmetsa, KV
    Leidy, RB
    JOURNAL OF AOAC INTERNATIONAL, 1999, 82 (06) : 1550 - 1561
  • [4] Analysis of carbamate pesticides by micellar electrokinetic chromatography
    Rossi, M
    Rotilio, D
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1997, 20 (05): : 265 - 269
  • [5] Separation of nucleotides by micellar electrokinetic chromatography
    Ming, YF
    Zhao, YF
    Li, XJ
    Zhang, HL
    Chen, L
    Li, YM
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (02) : 227 - 230
  • [6] SEPARATION OF ESTROGENS BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    CHAN, KC
    MUSCHIK, GM
    ISSAQ, HJ
    SIITERI, PK
    JOURNAL OF CHROMATOGRAPHY A, 1995, 690 (01) : 149 - 154
  • [7] Capillary Separation: Micellar Electrokinetic Chromatography
    Terabe, Shigeru
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, 2009, 2 : 99 - 120
  • [8] SEPARATION OF PHTHALATES BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    ONG, CP
    LEE, HK
    LI, SFY
    JOURNAL OF CHROMATOGRAPHY, 1991, 542 (02): : 473 - 481
  • [9] ENANTIOMERIC SEPARATION BY MICELLAR ELECTROKINETIC CHROMATOGRAPHY
    OTSUKA, K
    TERABE, S
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (04) : 125 - 130
  • [10] Combination of orthogonal array design and triangle overlapping resolution mapping scheme for resolution optimization in micellar electrokinetic chromatography
    Zhang, YP
    Yuan, ZB
    ANALYTICAL SCIENCES, 2003, 19 (06) : 945 - 948