Experimental study on orthogonal joints in cross-laminated timber with self-tapping screws installed with mixed angles

被引:48
作者
Brown, Justin R. [1 ]
Li, Minghao [1 ]
Tannert, Thomas [2 ]
Moroder, Daniel [3 ]
机构
[1] Univ Canterbury, Dept Civil & Nat Resources Engn, Canterbury, New Zealand
[2] Univ Northern British Columbia Prince George, Sch Engn, Prince George, BC, Canada
[3] PTL Struct Consultants, Christchurch, New Zealand
基金
澳大利亚研究理事会;
关键词
Cross-laminated timber; Orthogonal joints; Self-tapping screws; Mixed angle installations; Ductility; Overstrength; SEISMIC PERFORMANCE; CONNECTIONS; DESIGN; BEHAVIOR; DUCTILITY; WALL;
D O I
10.1016/j.engstruct.2020.111560
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) is increasingly being used in lateral load resisting systems of multi-storey buildings. Conventional in-plane CLT shear walls can be transformed into CLT core-wall structures with enhanced lateral strength and stiffness when the individual walls are connected orthogonally. In this paper, experimental studies are presented on orthogonal CLT joints with self-tapping screws (STS) installed with mixed angles, i.e. different installation angles between the STS axis and the plane of the CLT surface. A total of 59 orthogonal joint specimens were tested in 9 different configurations to derive the relevant joint performance parameters from monotonic and cyclic tests. The joint specimens used five-layer and seven-layer CLT panels connected by empty set8 mm or by empty set12 mm STS. Different ratios of STS installed inclined and STS installed at 90 degrees to the CLT surface were investigated to determine an optimum ratio of STS for enhanced joint performance. It was found that a ratio of one 90 STS for every two inclined STS ensured significant increase in ductility and displacement capacity of approximately three times when compared to specimens with only inclined STS. A minimum moderate ductility was achieved in all test series where the primary failure mode was STS withdrawal. It was found that 90 degrees STS contributed to both strength and stiffness in joints that also contained inclined STS. The average experimental overstrength was 1.7 for most joint configurations. Existing analytical models were adequate in estimating strength but inadequate to estimate stiffness.
引用
收藏
页数:14
相关论文
共 68 条
[1]   Systematic experimental investigation to support the development of seismic performance factors for cross laminated timber shear wall systems [J].
Amini, M. Omar ;
van de Lindt, John W. ;
Rammer, Douglas ;
Pei, Shiling ;
Line, Philip ;
Popovski, Marjan .
ENGINEERING STRUCTURES, 2018, 172 :392-404
[2]  
Bejtka I., 2002, CIB W18 M TIMB STRUC, V35, P141, DOI [https://doi.org/10.5445/IR/13752002, DOI 10.5445/IR/13752002]
[3]  
Below K, 2016, WCTE 2016 WORLD C TI
[4]  
Blass H.J., 2006, Karlsruher Berichte zum Ingenieurholzbau: Lehrstuhl fur Ingenieurholzbau und Baukonstruktionen
[5]   Cross laminated timber (CLT): overview and development [J].
Brandner, R. ;
Flatscher, G. ;
Ringhofer, A. ;
Schickhofer, G. ;
Thiel, A. .
EUROPEAN JOURNAL OF WOOD AND WOOD PRODUCTS, 2016, 74 (03) :331-351
[6]  
Breneman S., 2019, Woodworks
[7]  
Brown J, 2020, 17 WORLD C EARTHQ EN
[8]  
Brown J, 2020, N Z TIMBER DES SOC J, V28
[9]   Structural performance of dowelled cross-laminated timber hold-down connections with increased row spacing and end distance [J].
Brown, Justin R. ;
Li, Minghao .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 271
[10]   Experimental Testing of a Low-Damage Post-Tensioned C-Shaped CLT Core-Wall [J].
Brown, Justin R. ;
Li, Minghao ;
Palermo, Alessandro ;
Pampanin, Stefano ;
Sarti, Francesco .
JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (03)